High-voltage high-frequency transformer design for a 7.2kV to 120V/240V 20kVA solid state transformer
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Solid state transformer (SST) exhibits good features such as high power density, small volume and weight, controlled power factor, voltage sag ride through, etc. compared with traditional line frequency transformer. The 7.2 kV AC to 120V/240V AC 20 kVA solid state transformer is a key component of the future renewable electric energy delivery and management (FREEDM) systems as the interface between the 7.2 kV distribution grid and the low voltage residential micro-grid. Three cascaded 6.7 kVA high-voltage high-frequency transformers operating at 3 kHz are employed to convert voltage from 3800 V high voltage DC link of each cascaded stage to 400 V low voltage DC link. The transformer is required to withstand at least 15 kV high frequency voltage insulation continuously. Transformer magnetic core materials were reviewed and compared. Winding layout alternatives for leakage, magnetizing inductance and insulation were compared. An insulation strategy based on split core and separate winding structure with inserted insulation layer between the C cores was proposed. One 6.7 kVA high voltage high frequency transformer prototype was built and the test results were reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
Self-citationDesign and optimization of medium frequency, medium voltage transformers
Shuai, P., & Biela, J. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634423 · Cited by 43
“Previous research focusing on MFT design has been introduced in [1] [2] [3] for traction applications and in [4] [5] for renewable energy and smart grid applications.”
Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331701 · Cited by 37
“[26] reviewed and compared different magnetic core materials for PET high-voltage high-frequency transformer, and a 3-kHz 6.”
Background
Metadata
- Authors
- Du, Y., Baek, S., Bhattacharya, S., & Huang, A. Q.
- Venue
- IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society
- Publisher
- IEEE
- Published
- 2010-11
- Pages
- 493-498
- ISSN
- 1553-572X (ISSN-L)
- OpenAlex
- W2142138792
- Cited by
- 120
- References
- 1
- FWCI
- 4.37
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-voltage high-frequency transformer design for a 7.2kV to 120V/240V 20kVA solid state transformer. https://app.cochat.ai/papers/10.1109/iecon.2010.5674828
- The paper
- Du, Y., Baek, S., Bhattacharya, S., & Huang, A. Q. (2010). High-voltage high-frequency transformer design for a 7.2kV to 120V/240V 20kVA solid state transformer. IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society. https://doi.org/10.1109/iecon.2010.5674828
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.