Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 31 of the 33 references it cites were found in a registry or an index.

Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies

Wang, Xinyu, Liu, Jinjun, Ouyang, Shaodi, Meng, Fei · 2015 · IEEE Transactions on Power Electronics

Abstract

Compared with conventional power transformer, power electronic transformer (PET) has many merits and an increasing possibility to replace it in the future. In this paper, the unbalanced-load correction capability of two H-bridge based three-phase three-stage modular PET topologies, the separate-phase-connection (SPC) one and the cross-phase-connection (CPC) one, are analyzed and compared. Both of the SPC and CPC consist of three stages: a modular multilevel ac-dc input stage, an isolation stage with several independent modular dual active bridge (DAB) dc-dc converters, and a dc-ac output stage with single-phase-inverter parallel-connected structure. Based on the control strategy, it is found that the SPC is suitable for dealing with full-range unbalanced load under the condition of increasing the input-stage current stress. For the SPC feeding, one load or three loads with identical power polarity, the current stress shall be theoretically increased up to 115% of the rated one, while the percentage is 153% when the SPC feeds three loads with different power polarity. On the contrary, the CPC is only suitable for dealing with partial unbalanced-load conditions. Extendedly, the third so-called full-range-power auto-balance PET is proposed to deal with unbalanced load, the performance of which is verified by simulation results. A downscaled prototype for SPC and CPC is built and tested. Experimental results verify the unbalanced-load correction performance of SPC and CPC.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpel.2014.2331701

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. du, 0, High-voltage high-frequency transformer design for a 7.2�kV to 120�V/240�V 20 kVA solid state transformer, Proc IEEE 36th Annu Ind Electron Conf, 493

Cited by

See all 37

Metadata

Authors
Wang, X., Liu, J., Ouyang, S., & Meng, F.
Affiliations
State Key Laboratory of Electrical Insulation and Power Equipment (CN)
Venue
IEEE Transactions on Power Electronics
Published
2015-06
Volume
30
Issue
6
Pages
3044-3056
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W2027201238
Cited by
37
References
33
Citations by year
2025: 1 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 7 · 2020: 1 · 2019: 5 · 2018: 5 · 2017: 3 · 2016: 5 · 2015: 2
FWCI
1.77
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Electronics (publishedVersion)
Funders
U.S. Department of Commerce
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
Keywords
solid-state transformer, H-bridge topology, modular multilevel converter, dual active bridge converter

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies. https://app.cochat.ai/papers/10.1109/tpel.2014.2331701
The paper
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015). Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2014.2331701

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.