A Numerical Analysis Of The Electric Field Generated By A Nerve Cuff Electrode
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have developed a three dimensional finite element model of an unifascicular nerve and studied the effects of electrode configurations and the effects of tissue conductivities in and around the nerve trunk on the potential distribution due to a cuff electrode. From the potential distribution we can estimate the region of the nerve trunk where fibers of specific diameter are excited. Our results indicate that selective activation of the nerve fibers was affected by the anisotropy of the nerve trunk and the perineurium. Tripolar configuration with a smaller spacing between the anodes and the cathode, was more effective in confining the current to the superficial regions of the nerve trunk relative to a monopolar configuration and selectivity of exatation was further improved by steering the current with an anode located across the cathode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Self-citation
Cited by
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Modeling the effects of electric fields on nerve fibers: Determination of excitation thresholds
Warman, E. N., Grill, W. M., & Durand, D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184700 · Cited by 326
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Self-citationInversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
Self-citationGrill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103
“However, previous results demonstrated that inversion/eversion torques are insignificant at the cat ankle joint and the internal and external rotation torques are generally only 10–20% of the plantar- and dorsiflexion torques [12], [13], [15].”
MethodResultSelf-citation
Metadata
- Authors
- Chintalacharuvu, R. R., Ksienski, D. A., & Mortimer, J. T.
- Venue
- Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991
- Publisher
- IEEE
- Published
- 2005-08-24
- Pages
- 912-913
- OpenAlex
- W2539030526
- Cited by
- 29
- References
- 2
- FWCI
- 1.23
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Numerical Analysis Of The Electric Field Generated By A Nerve Cuff Electrode. https://app.cochat.ai/papers/10.1109/iembs.1991.684258
- The paper
- Chintalacharuvu, R. R., Ksienski, D. A., & Mortimer, J. T. (2005). A Numerical Analysis Of The Electric Field Generated By A Nerve Cuff Electrode. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society Volume 13: 1991. https://doi.org/10.1109/iembs.1991.684258
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.