Noise Cancellation Model Validation for Reduced Motion Artifact Wearable PPG Sensors Using MEMS Accelerometers
Abstract
This paper investigates the validity of utilizing Widrow's Active Noise Cancellation (ANC) in the context of motion artifact reduction for photoplethysmogram (PPG) sensors. The ANC approach has previously been applied to the PPG problem, but little consideration has been given to the validity of the ANC signal corruption assumptions and in what motion range the algorithm works. The ANC validity testing is done in the form of impact (approximate impulse) testing of the physical PPG system and comparing with the modeled response for a range of motion amplitudes. The testing reveals that the identified corruption model does not generally represent the true physical system, but locally approximates the true system. Testing shows that if a similar motion amplitude is used for model tuning as the impact test, an average peak deviation of 5.2% is obtained, but if motion amplitude that is smaller than the impact amplitude by a factor of 5, the peak deviation is 15%. Finally, after ANC filtering motion corrupted data, heart rate can be estimated with less than 1.6% error.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ambulatory data measured with wearable sensors, mobile phones, and surveys tend to be noisy.
“Ambulatory data measured with wearable sensors, mobile phones, and surveys tend to be noisy.”
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690 · see citing works
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,215 · see citing works
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · see citing works
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466 · see citing works
Self-citationMotion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400 · see citing works
Aminian, K., Robert, P. A., Buchser, E., Rutschmann, B., Hayoz, D., & Depairon, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513304 · Cited by 309 · see citing works
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · see citing works
Self-citationMonitoring of respiratory rate in postoperative care using a new photoplethysmographic technique
Nilsson, L. M., Johansson, A., & Kálmán, S. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011424732717 · Cited by 157 · see citing works
Quantification of physical activities by means of ambulatory accelerometry: A validation study
Bussmann, J. B. J., Tulen, J. H. M., van Herel, E. C. G., & Stam, H. J. (1998) · Psychophysiology · doi:10.1017/s0048577298971153 · Cited by 142 · see citing works
Adaptive reduction of motion artifact in the electrocardiogram
Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1106451 · Cited by 122 · see citing works
Adaptive noise cancelling of motion artifact in stress ECG signals using accelerometer
Raya, M. A. D., & Sison, L. G. (2002) · doi:10.1109/iembs.2002.1106637 · Cited by 98 · see citing works
Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers
Relente, A. R., & Sison, L. G. (2002) · doi:10.1109/iembs.2002.1106644 · Cited by 60 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · see citing works
“6% [74].”
Sano, A., Taylor, S., McHill, A. W., Phillips, A. J., Barger, L. K., Klerman, E., & Picard, R. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9410 · Cited by 333 · see citing works
“To address these issues, various techniques have been applied, such as data cleaning before data analysis [31]: data quality evaluation [32], detecting faulty data, noise reduction [33], and interpolating faulty or missing values [34,35].”
MethodCurrent progress of photoplethysmography and SPO2 for health monitoring
TAMURA, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 260 · see citing works
A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time
Buxi, D., Redouté, J., & Yuce, M. R. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/r1 · Cited by 140 · see citing works
Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
Karlen, W., Kobayashi, K., Ansermino, J. M., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1617 · Cited by 123 · see citing works
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101 · see citing works
Fiorini, L., Mancioppi, G., Semeraro, F., Fujita, H., & Cavallo, F. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.105217 · Cited by 73 · see citing works
A new method for heart rate monitoring during physical exercise using photoplethysmographic signals
Schäck, T., Sledz, C., Muma, M., & Zoubir, A. M. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362868 · Cited by 58 · see citing works
Convertino, V. A., Schauer, S. G., Weitzel, E. K., Cardin, S., Stackle, M. E., Talley, M. J., Sawka, M. N., & Inan, O. T. (2020) · Sensors · doi:10.3390/s20226413 · Cited by 49 · see citing works
Schäck, T., Muma, M., & Zoubir, A. M. (2017) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2017.8081656 · Cited by 46 · see citing works
Wang, M., Li, Z., Zhang, Q., & Wang, G. (2019) · Sensors · doi:10.3390/s19153312 · Cited by 39 · see citing works
Comtois, G., Mendelson, Y., & Ramuka, P. R. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352592 · Cited by 36 · see citing works
Murthy, N. K. L., Madhusudana, P. C., Suresha, P. B., Periyasamy, V., & Ghosh, P. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2486681 · Cited by 32 · see citing works
Feasibility of Intelligent Monitoring of Construction Workers for Carbon Monoxide Poisoning
Forsyth, J. B., Martin, T. L., Young-Corbett, D. E., & Dorsa, E. (2012) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2012.2197390 · Cited by 31 · see citing works
Shin, H., Lee, C., & Lee, M. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9289-2 · Cited by 29 · see citing works
Gautam, Y., & Jebelli, H. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105537 · Cited by 27 · see citing works
Multi-channel pulse oximetry for wearable physiological monitoring
Mendelson, Y., Dao, D. K., & Chon, K. H. (2013) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2013.6575518 · Cited by 27 · see citing works
Wander, J. D., & Morris, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2543 · Cited by 21 · see citing works
Comtois, G., & Mendelson, Y. (2007) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2007.4413301 · Cited by 17 · see citing works
Wearable Integrated Online Fusion Learning Filter for Heart PPG Sensing Tracking
Wen, H., Gao, B., Yang, D., Zhang, Y., Huang, L., & Woo, W. L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3277719 · Cited by 16 · see citing works
Alzahrani, A., Hu, S., & Azorin-Peris, V. (2015) · Biosensors · doi:10.3390/bios5020288 · Cited by 14 · see citing works
Accelerometer-assisted PPG Measurement During Physical Exercise Using the LAVIMO Sensor System
Santos, S. A., Venema, B., & Leonhardt, S. K. (2012) · Acta Polytechnica · doi:10.14311/1646 · Cited by 13 · see citing works
Zhang, Q., Xie, Q., Wang, M., & Wang, G. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512878 · Cited by 13 · see citing works
TAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 7 · see citing works
Comparative evaluation of adaptive filters in motion artifact cancellation for pulse oximetry
Kunchon, S., Desudchit, T., & Chinrungrueng, C. (2009) · IEEE International Colloquium on Signal Processing & Its Applications (CSPA) · doi:10.1109/cspa.2009.5069240 · Cited by 7 · see citing works
Security and Privacy in Biomedical Telemetry: Mobile Health Platform for Secure Information Exchange
Bourbakis, N., Pantelopoulos, A., & Kannavara, R. (2014) · doi:10.1002/9781118893715.ch13 · Cited by 7 · see citing works
Gautam, Y., & Jebelli, H. (2024) · ASCE Construction Research Congress (CRC) · doi:10.1061/9780784485293.072 · Cited by 5 · see citing works
Motion-Resistant Pulse Oximetry Processing Based on Time-Frequency Analysis
Leeudomwong, T., Deesudchit, T., & Chinrungrueng, C. (2017) · Engineering Journal · doi:10.4186/ej.2017.21.7.181 · Cited by 4 · see citing works
Pflugradt, M., & Orglmeister, R. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943975 · Cited by 4 · see citing works
Dual Wavelength Photoplethysmography Framework for Heart Rate Calculation
Alkhoury, L., Choi, J., Chandran, V. D., Carvalho, G. B. D., Pal, S., & Kam, M. (2022) · Sensors · doi:10.3390/s22249955 · Cited by 3 · see citing works
Pantelopoulos, A., & Bourbakis, N. (2010) · International Conference on Body Area Networks · doi:10.1145/2221924.2221966 · Cited by 3 · see citing works
Nakazawa, T., Morishita, K., Ienaka, A., Fujii, T., Ito, M. A., & Matsushita, F. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.10.107001 · Cited by 2 · see citing works
Comparative and evaluative the adaptive filter in motion artifact cancellation of pulse oximetry
Kunchon, S., Desudchit, T., & Chinrungrueng, C. (2009) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2009.4967809 · Cited by 2 · see citing works
Signal Quality Assessment for Wearable Multichannel Photoplethysmography Signals
Prihatmoko, M. D., Ahmadi, N., Charlton, P. H., & Adiono, T. (2023) · Asia-Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC) · doi:10.1109/apsipaasc58517.2023.10317377 · Cited by 2 · see citing works
Feasibility study of a wearable carbon monoxide warning system for construction workers
Forsyth, J. B., Martin, T. L., Young-Corbett, D. E., & Dorsa, E. (2011) · IEEE International Conference on Pervasive Computing and Communications · doi:10.1109/percom.2011.5767592 · Cited by 1 · see citing works
Wearable Pulse Oximetry in Construction Environments
Forsyth, J. B. (2010) · VTechWorks (Virginia Tech) · Cited by 1 · see citing works
Mendelson, Y., & Comtois, G. (2007)
Hardware and Algorithmic Approaches to Combat Motion Artifacts in Photoplethysmographic Data
Han, D., Mohagheghian, F., & Chon, K. H. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00135-7
Sullivan, J., & Alam, M. A. U. (2022) · International Conference on Mobility, Sensing and Networking (MSN) · doi:10.1109/msn57253.2022.00062
- Authors
- Wood, L. B., & Asada, H. H.
- Affiliations
- Massachusetts Institute of Technology (US)
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 3525-3528
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2107290914
- Cited by
- 39
- References
- 12
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 3 · 2018: 2 · 2017: 3 · 2015: 4 · 2014: 4 · 2013: 1 · 2012: 3
- FWCI
- 4.04
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Computational Mechanics › Advanced Adaptive Filtering Techniques
- Keywords
- active noise control, motion artifact reduction, photoplethysmography, wearable sensors, MEMS accelerometer, impact testing, model validation, heart rate estimation
- MeSH terms
- Acceleration, Biomedical Engineering, Equipment Design, Humans, Motion, Signal Processing, Computer-Assisted, Models, Statistical, Photoplethysmography, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review