Stimulus-resistant neural recording amplifier
The DOI matches its Crossref record.
Abstract
The capability to use the same microelectrode for electrical stimulation of neurons, as well as for neural signal recording from neurons in the vicinity of the electrode, has historically been a goal of neuroscientists. During, and after, stimulation the stimulus artifact effectively disables the recording system until the residual effects of the artifact have dissipated. The only practical way to successfully record neural signals in the presence of stimulus pulses is to fully integrate the constant-current bi-directional stimulation circuitry with a specialized bioelectric recording amplifier on the same electronic chip. This is because post-stimulus electrode polarization recovery, amplifier blanking, and low-noise amplifier circuitry must be intimately tied to the stimulus circuitry, and such functional integration can only be obtained by implementing the combined circuitry as one application specific integrated circuit (ASIC) design. Toward this goal, a topology for a neural recording amplifier with rapid recovery characteristics was designed and tested using discrete components, and was successfully used to suppress stimulation artifacts generated by a nearby electrode in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“The most common electrical approach is to use ‘blanking’ [54], [55] where recording amplifiers are disconnected from”
BackgroundShadmani, A., Viswam, V., Chen, Y., Bounik, R., Dragas, J., Radivojevic, M., Geissler, S., Sitnikov, S., Muller, J., & Hierlemann, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2890530 · Cited by 24
“These techniques reported in [26]–[28], [32], [33] include to remove stimulation artifacts from or discharge the stimulating electrode itself.”
InfluentialSensing of stimulus artifact suppressed signals from electrode interfaces.
Nag, S., Sikdar, S. K., Thakor, N. V., Rao, V. R., & Sharma, D. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2399248 · Cited by 20
“from instability [18].”
Metadata
- Authors
- DeMichele, G. A., & Troyk, P. R.
- Venue
- Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439)
- Publisher
- IEEE
- Published
- 2004-05-13
- Pages
- 3329-3332
- OpenAlex
- W1567728070
- Cited by
- 26
- References
- 0
- FWCI
- 3.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.