A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This work presents a new multi-site probe array applied with parylene technology, used for neural prostheses to record high-level cognitive neural signals. Instead of inorganic materials (e.g. silicon dioxide, silicon nitride), the electrodes and conduction traces on probes are insulated by parylene, which is a polymer material with high electrical resistivity, mechanical flexibility, biocompatibility and easy deposition process. As a result, the probes exhibit better electrical and mechanical properties. The all dry process is demonstrated to fabricate these probe arrays with monolithically integrated parylene flexible cables using double-side-polished (DSP) wafers. With the parylene flexible cables, the probes can be easily assembled to a high density 3-D array for chronic implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“I. INTRODUCTION IRECT brain interfaces called neural prostheses are being designed that will enable a primate, via surgically implanted electrode arrays and associated computer algorithms, to control external electromechanical devices by pure thought alone (Fig.”
BackgroundSelf-citationWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Cited by
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Azemi, E., Stauffer, W. R., Gostock, M. S., Lagenaur, C. F., & Cui, X. T. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.02.028 · Cited by 97
Seidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68
Design and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4
“Also parylene-C has obtained the highest biocompatibility rating; class VI, from the United States Pharmacopeia (USP)[1,32].”
Background
Metadata
- Authors
- Pang, C., Cham, J. G., Nenadic, Z., Musallam, S., Tai, Y.-C., Burdick, J. W., & Andersen, R. A.
- Venue
- 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
- Publisher
- IEEE
- Published
- 2005
- Volume
- 2005
- Pages
- 7114-7117
- OpenAlex
- W2096956842
- Cited by
- 48
- References
- 2
- FWCI
- 14.80
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses. https://app.cochat.ai/papers/10.1109/iembs.2005.1616146
- The paper
- Pang, C., Cham, J. G., Nenadic, Z., Musallam, S., Tai, Y.-C., Burdick, J. W., & Andersen, R. A. (2005). A New Multi-Site Probe Array with Monolithically Integrated Parylene Flexible Cable for Neural Prostheses. 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference. https://doi.org/10.1109/iembs.2005.1616146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.