Stress Detection in Computer Users Based on Digital Signal Processing of Noninvasive Physiological Variables
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
A stress detection system is developed based on the physiological signals monitored by non-invasive and non-intrusive sensors. The development of this emotion recognition system involved three stages: experiment setup for physiological sensing, signal preprocessing for the extraction of affective features and affective recognition using a learning system. Four signals: galvanic skin response (GSR), blood volume pulse (BVP), pupil diameter (PD) and skin temperature (ST) are monitored and analyzed to differentiate affective states in a computer user. A support vector machine is used to perform the supervised classification of affective states between "stress" and "relaxed". Results indicate that the physiological signals monitored do, in fact, have a strong correlation with the changes in emotional state of our experimental subjects when stress stimuli are applied to the interaction environment. It was also found that the pupil diameter was the most significant affective state indicator, compared to the other three physiological signals monitored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Studies of interference in serial verbal reactions
Stroop, J. R. (1935) · Journal of Experimental Psychology · doi:10.1037/h0054651 · Cited by 18,622
Text categorization with Support Vector Machines: Learning with many relevant features
Joachims, T. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0026683 · Cited by 7,999
Picard, R. W. (1997) · MIT Press · doi:10.7551/mitpress/1140.001.0001 · Cited by 7,382
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Pupil size variation as an indication of affective processing
Partala, T., & Surakka, V. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00017-x · Cited by 836 · cited 1×
“This phenomenon makes the pupil diameter prominent amongst physiological signals used for affective state assessment, confirming results from previous research which indicated that the pupil diameter could be an effective indicator of the affective states during tests that used the standard International Affective Dig…”
ResultTo feel or not to feel: The role of affect in human–computer interaction
Hudlicka, E. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00047-8 · Cited by 391
Selye's Guide to Stress Research
Selye, H. (1980) · Medical Entomology and Zoology · Cited by 345
Cited by
Review on Psychological Stress Detection Using Biosignals
Giannakakis, G., Grigoriadis, D., Giannakaki, K., Simantiraki, O., Roniotis, A., & Tsiknakis, M. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2019.2927337 · Cited by 764
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742
“Zhai and Barreto [ 19 ] used an interactive ‘Paced Stroop test,” where subjects had to select the font color of a word shown on the screen.”
MethodSharma, N., & Gedeon, T. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.07.003 · Cited by 510
Alberdi, A., Aztiria, A., & Basarab, A. (2016) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.11.007 · Cited by 473
Review of Eye Tracking Metrics Involved in Emotional and Cognitive Processes
Skaramagkas, V., Giannakakis, G., Ktistakis, E., Manousos, D., Karatzanis, I., Tachos, N., Tripoliti, E., Marias, K., Fotiadis, D. I., & Tsiknakis, M. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3066072 · Cited by 419
Self-Supervised ECG Representation Learning for Emotion Recognition
Sarkar, P., & Etemad, A. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3014842 · Cited by 383
Monitoring stress with a wrist device using context
Gjoreski, M., Luštrek, M., Gams, M., & Gjoreski, H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.08.006 · Cited by 352
cStress: towards a gold standard for continuous stress assessment in the mobile environment
Hovsepian, K., al'Absi, M., Ertin, E., Kamarck, T., Nakajima, M., & Kumar, S. (2015) · Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2750858.2807526 · Cited by 339
A Stress Sensor Based on Galvanic Skin Response (GSR) Controlled by ZigBee
Villarejo, M. V., Zapirain, B. G., & Zorrilla, A. M. (2012) · Sensors · doi:10.3390/s120506075 · Cited by 315
Activity-Aware Mental Stress Detection Using Physiological Sensors
Sun, F.-T., Kuo, C., Cheng, H.-T., Buthpitiya, S., Collins, P., & Griss, M. (2012) · Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-642-29336-8_12 · Cited by 292
The Role of Nonlinear Dynamics in Affective Valence and Arousal Recognition
Valenza, G., Lanata, A., & Scilingo, E. P. (2012) · IEEE Transactions on Affective Computing · doi:10.1109/t-affc.2011.30 · Cited by 252
Large-scale wearable data reveal digital phenotypes for daily-life stress detection
Smets, E., Rios Velazquez, E., Schiavone, G., Chakroun, I., D’Hondt, E., De Raedt, W., Cornelis, J., Janssens, O., Van Hoecke, S., Claes, S., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0074-9 · Cited by 250
Stress Detection Using Wearable Physiological and Sociometric Sensors
Mozos, O. M., Sandulescu, V., Andrews, S., Ellis, D., Bellotto, N., Dobrescu, R., & Ferrandez, J. M. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065716500416 · Cited by 208
“SVM-based predictors are popular in different areas [17, 21, 22] including the classification mental states using physiological signals [5, 7, 10, 29, 34, 37, 51, 68, 77].”
InfluentialDe Arriba-Pérez, F., Caeiro-Rodríguez, M., & Santos-Gago, J. (2016) · Sensors · doi:10.3390/s16091538 · Cited by 153
Utilizing a wristband sensor to measure the stress level for people with dementia
Kikhia, B., Stavropoulos, T., Andreadis, S., Karvonen, N., Kompatsiaris, I., Sävenstedt, S., Pijl, M., & Melander, C. (2016) · Sensors · doi:10.3390/s16121989 · Cited by 89
“Many studies suggested the use of physiological signals to detect stress and measure emotions of people, such as Skin Conductance [14], Blood Volume Pulse (BVP) [15] and Electroencephalography (EGG) [16].”
BackgroundMentis, A.-F. A., Lee, D., & Roussos, P. (2024) · Molecular Psychiatry · doi:10.1038/s41380-023-02047-6 · Cited by 75
“SVM is widely used for detecting stress levels since the fl exible, kernel-based mathematics of SVM make it suitable for accurate prediction of non-linear pattern recognition problems [73].”
Metadata
- Authors
- Zhai, J., & Barreto, A.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 1355-1358
- OpenAlex
- W1510429593
- Cited by
- 287
- References
- 16
- FWCI
- 7.04
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.