Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Intracortical microelectrodes currently have great potential as a neural prosthesis in patients with neurodegenerative disease or spinal cord injury. In an effort to improve the consistency of neural probe performance, many modifications to probe design are focused on reducing the tissue encapsulation. Since researchers have shown that small polymer fibers (less than 7-microm diameter) induce a small to non-existent encapsulation layer in the rat subcutis, we have proposed a neural probe design with similarly small diameter structures. This paper discusses the fabrication and design parameters of a microscale neural probe with a sub-cellular lattice structure. We developed a microfabrication process using SU-8 and parylene-C to create the relatively thick probe shank and thin lateral arms. The stiff penetrating shank (70-microm by 42-microm) had an SU-8 core that allowed control over stiffness and simplified the process. Parylene-only structures lateral to the shank could be defined with a 4-microm feature-size to meet our sub-cellular criterion. We fabricated four varying geometries for implantation into the neocortex of seven Sprague-Dawley rats. Our in vivo testing verifies that despite the flexible substrate and small dimensions (4-microm x 5-microm), these devices are mechanically robust and practical as neural probes. These devices provide an important tool for neural engineers to investigate the tissue response around sub-cellular structures and potentially improve device efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“Researchers are investigating a variety of techniques to prevent neuronal loss and cellular encapsulation by modulating the acute immune response and long-term reactivity [ 9 ].”
BackgroundBiran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · cited 1×
“Histological examination has consistently shown that a glial scar forms around the probe tract [ 3-5 ].”
BackgroundChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 1×
“An increase in electrical impedance is concomitant with the time course of this reactivity and is therefore believed to be the cause of attenuated and noisy signal recordings [ 6-8 ].”
BackgroundLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 1×
“An increase in electrical impedance is concomitant with the time course of this reactivity and is therefore believed to be the cause of attenuated and noisy signal recordings [ 6-8 ].”
BackgroundSelf-citation
Cited by
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
Metadata
- Authors
- Seymour, J. P., & Kipke, D. R.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 4606-4609
- OpenAlex
- W2123023667
- Cited by
- 35
- References
- 4
- FWCI
- 3.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation. https://app.cochat.ai/papers/10.1109/iembs.2006.260528
- The paper
- Seymour, J. P., & Kipke, D. R. (2006). Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation. 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2006.260528
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.