A simple test to assess the static and dynamic accuracy of an inertial sensors system for human movement analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In the present study we introduced a simple test to assess the orientation error of an inertial sensors system for human movement analysis, both in static and dynamic conditions. In particular, the test was intended to quantify the sensitivity of the orientation error to direction and velocity of rotation. The test procedure was performed on a 5 MT9B sensors Xsens acquisition system, and revealed that the system orientation error, expressed by Euler angles decomposition, was sensitive both to direction and to velocity, being higher for fast movements: for mean rotation velocities of 180 degrees/s and 360 degrees/s, the worst case orientation error was 5.4 degrees and 11.6 degrees, respectively. The test can be suggested therefore as a useful tool to verify the user specific system accuracy without requiring any special equipment. In addition, the test provides further error information concerning direction and velocity of the movement which are not supplied by the producer, since they depend on the specific field of application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Cited by
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
Self-citationCereatti, A., Gurchiek, R., Mündermann, A., Fantozzi, S., Horak, F., Delp, S., & Aminian, K. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112225 · Cited by 79
Fantozzi, S., Giovanardi, A., Magalhães, F. A., Di Michele, R., Cortesi, M., & Gatta, G. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1088659 · Cited by 74
Self-citationLebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65
“As discussed earlier, many authors have shown, in controlled conditions and for human motion, that an increase in velocity worsens the orientation data accuracy [11, 13, 14, 26], but current evidence is insufficient in determining the extent of the velocity effect on a variety of tasks measured at different segments.”
Enhancing accuracy and convenience of golf swing tracking with a wrist-worn single inertial sensor
Kim, M., & Park, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-59949-w · Cited by 14
Metadata
- Authors
- Cutti, A. G., Giovanardi, A., Rocchi, L., & Davalli, A.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 5912-5915
- OpenAlex
- W1509682174
- Cited by
- 36
- References
- 1
- FWCI
- 2.44
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.