Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units
Abstract
The analysis of the joint kinematics during swimming plays a fundamental role both in sports conditioning and in clinical contexts. Contrary to the traditional video analysis, wearable inertial-magnetic measurements units (IMMUs) allow to analyse both the underwater and aerial phases of the swimming stroke over the whole length of the swimming pool. Furthermore, the rapid calibration and short data processing required by IMMUs provide coaches and athletes with an immediate feedback on swimming kinematics during training. This study aimed to develop a protocol to assess the three-dimensional kinematics of the upper limbs during swimming using IMMUs. Kinematics were evaluated during simulated dry-land swimming trials performed in the laboratory by eight swimmers. A stereo-photogrammetric system was used as the gold standard. The results showed high coefficient of multiple correlation (CMC) values, with median (first-third quartile) of 0.97 (0.93-0.95) and 0.99 (0.97-0.99) for simulated front-crawl and breaststroke, respectively. Furthermore, the joint angles were estimated with an accuracy increasing from distal to proximal joints, with wrist indices showing median CMC values always higher than 0.90. The present findings represent an important step towards the practical use of technology based on IMMUs for the kinematic analysis of swimming in applied contexts.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Shoulder heterogeneity of results (RMSE 0.2-64.5° and r 0.69-1.00) and movements made it difficult to conclude validity.
“Despite a larger number of studies published for this joint, heterogeneity of results (RMSE between 0.2 and 64.5° and r from 0.69 to 1.00) and movements performed made it difficult to conclude the validity of using M/IMU systems for movement at this joint [31,32,33,34,35,37,38,39,42,43,44,45].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [32]
Elbow RMSE and correlation coefficient results ranged from 0.2 to 30.6° and 0.68 to 0.99, showing good to excellent validity.
“RMSE and correlation coefficient results range from 0.2 to 30.6° and 0.68 to 0.99, respectively, showing good to excellent validity [28,31,32,33,34,35,37,39,43,45].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [32]
Wrist RMSE and correlation coefficients varied from 2.2 to 30° and 0.62 to 0.99, showing fair to good validity.
“RMSE and correlation coefficients varied respectively from 2.2 to 30° and from 0.62 to 0.99, showing fair to good validity [28,32,33,35,37,43].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [32]
Studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table.
“For example, studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table [32,34].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [32]
Cites
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569 · see citing works
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S., Harrison, A. J., & Vaidyanathan, R. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,108 · see citing works
Journal of Sports Science and Medicine
Stewart, M. (2014) · Wilderness and Environmental Medicine · doi:10.1016/j.wem.2014.06.007 · Cited by 1,228 · see citing works
Robot sensor calibration: solving AX=XB on the Euclidean group
Park, F. C., & Martin, B. J. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.326576 · Cited by 576 · see citing works
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356 · see citing works
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311 · see citing works
Self-citationJoint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 263 · see citing works
3-D attitude representation of human joints: A standardization proposal
Woltring, H. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90191-0 · Cited by 251 · see citing works
Wearable inertial sensors in swimming motion analysis: a systematic review
Magalhães, F. A., Vannozzi, G., Gatta, G., et al. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.962574 · Cited by 164 · see citing works
Self-citationFerrari, A., Cutti, A. G., & Cappello, A. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.02.009 · Cited by 149 · see citing works
A framework for the definition of standardized protocols for measuring upper-extremity kinematics
Kontaxis, A., Cutti, A. G., Johnson, G. R., & Veeger, H. E. J. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.12.009 · Cited by 149 · see citing works
Lebel, K., Boissy, P., Hamel, M., & Duval, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0079945 · Cited by 115 · see citing works
Shoulder impingement in front-crawl swimming: II. analysis of stroking technique
Yanai, T., & Hay, J. G. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00006 · Cited by 112 · see citing works
Vries, W. H. K. D., Veeger, H. E. J., Cutti, A. G., Baten, C. T. M., & van der Helm, F. C. T. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.007 · Cited by 104 · see citing works
Front-Crawl Instantaneous Velocity Estimation Using a Wearable Inertial Measurement Unit
Dadashi, F., Crettenand, F., Millet, G. P., & Aminian, K. (2012) · Sensors · doi:10.3390/s121012927 · Cited by 97 · see citing works
Markerless analysis of front crawl swimming
Ceseracciu, E., SAWACHA, Z., Fantozzi, S., et al. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.06.003 · Cited by 81 · see citing works
Self-citationAutomatic front-crawl temporal phase detection using adaptive filtering of inertial signals
Dadashi, F., Crettenand, F., Millet, G. P., Seifert, L., Komar, J., & Aminian, K. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.778420 · Cited by 72 · see citing works
Embedded programming and real-time signal processing of swimming strokes
Sage, T. L., Bindel, A., CONWAY, P. P., et al. (2011) · Sports Engineering · doi:10.1007/s12283-011-0070-7 · Cited by 66 · see citing works
Velocity profiling using inertial sensors for freestyle swimming
Stamm, A., James, D. A., & Thiel, D. V. (2012) · Sports Engineering · doi:10.1007/s12283-012-0107-6 · Cited by 64 · see citing works
Estimation of hand forces and propelling efficiency during front crawl swimming with hand paddles
Gourgoulis, V., Aggeloussis, N., Vezos, N., et al. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.032 · Cited by 64 · see citing works
Upper limb joint angle tracking with inertial sensors
El‐Gohary, M., Holmstrom, L. A., Huisinga, J. M., King, E., McNames, J., & Horak, F. B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091362 · Cited by 56 · see citing works
Shoulder impingement in front-crawl swimming: I. a method to identify impingement
Yanai, T., Hay, J. G., & MILLER, G. F. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200001000-00005 · Cited by 53 · see citing works
Stroke phase discrimination in breaststroke swimming using a tri-axial acceleration sensor device
Ohgi, Y., Ichikawa, H., Homma, M., et al. (2003) · Sports Engineering · doi:10.1007/bf02903532 · Cited by 50 · see citing works
Kinematic differences between front crawl sprint and distance swimmers at a distance pace
McCabe, C. B., & Sanders, R. H. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.660186 · Cited by 48 · see citing works
Silvatti, A. P., Cerveri, P., Telles, T., et al. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.664637 · Cited by 47 · see citing works
Comparison of different camera calibration approaches for underwater applications
Silvatti, A. P., Dias, F., Cerveri, P., et al. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.004 · Cited by 47 · see citing works
Motion analysis of front crawl swimming applying CAST technique by means of automatic tracking
Ceccon, S., Ceseracciu, E., SAWACHA, Z., et al. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.729134 · Cited by 38 · see citing works
Cutti, A. G., Giovanardi, A., Rocchi, L., & Davalli, A. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260705 · Cited by 37 · see citing works
Self-citationEffectiveness of an automatic tracking software in underwater motion analysis.
Magalhães, F. A., SAWACHA, Z., Michele, R. D., et al. (2013) · PubMed · Cited by 27 · see citing works
Self-citationEstimation of Front-Crawl Energy Expenditure Using Wearable Inertial Measurement Units
Dadashi, F., Millet, G. P., & Aminian, K. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2292585 · Cited by 18 · see citing works
A calibration process for tracking upper limb motion with inertial sensors
Yang, H., & Ye, J. (2011) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2011.5985732 · Cited by 15 · see citing works
Effects of distance specialization on the backstroke swimming kinematics.
Cortesi, M., Fantozzi, S., & Gatta, G. (2012) · PubMed · Cited by 13 · see citing works
Self-citationRicci, L., Formica, D., Tamilia, E., et al. (2013) · doi:10.1109/embc.2013.6610647 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Exploring the Role of Wearable Technology in Sport Kinematics and Kinetics: A Systematic Review
Adesida, Y., Papi, E., & McGregor, A. H. (2019) · Sensors · doi:10.3390/s19071597 · Cited by 288 · see citing works
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123 · see citing works
- Authors
- Fantozzi, S., Giovanardi, A., Magalhães, F. A., Di Michele, R., Cortesi, M., & Gatta, G.
- Affiliations
- University of Bologna (IT)
- Corresponding author
- Fantozzi, Silvia
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2015-09-14
- Volume
- 34
- Issue
- 11
- Pages
- 1073-1080
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2207598598
- Cited by
- 74
- References
- 33
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 10 · 2021: 10 · 2020: 7 · 2019: 14 · 2018: 5 · 2017: 6 · 2016: 3 · 2015: 1
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Sports Sciences (publishedVersion)
- PubMed (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
- Keywords
- swimming kinematics, wearable sensors, freestyle swimming, breaststroke, stereophotogrammetry
- MeSH terms
- Kinanthropometry, Adult, Biomechanical Phenomena, Humans, Joints, Male, Models, Anatomic, Swimming, Range of Motion, Articular, Upper Extremity, Young Adult, Athletes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review