Wearable Seismocardiography
The DOI matches its Crossref record.
Abstract
Seismocardiogram (SCG) is the recording of body vibrations induced by the heart beat. SCG contains information on cardiac mechanics, in particular heart sounds and cardiac output. In this paper we present a new wearable device for SCG recordings during long term monitorings, and the results of a validation test in 4 subjects. The system is based on the integration of the MagIC smart shirt (i.e., a textile-based wearable system for the assessment of ECG and respiratory movements), and an external triaxial MEMS accelerometer positioned on the left clavicle. SCG was estimated as the average of accelerations occurred in each heart beat. The SCG components due to the valve closure and to recoil forces following the heart contraction (ballistocardiogram) were extracted by high-pass (>18 Hz) and band-pass (0.6-20 Hz) filters respectively. Then the difference between the I and J waves of the ballistocardiogram (|I-J| index, possibly related to the cardiac output) was identified by an ad-hoc procedure and compared with the model flow indirect estimation of cardiac output. Validation on 4 volunteers showed that: 1) our wearable system provides statistically consistent estimates of both heart-sound related vibrations and recoil movements; 2) reliable estimates of the |I-J| index can be obtained by considering about 1 minute of SCG recording in stationary conditions; and 3) changes of the |I-J| index during exercise correlate well with changes of cardiac output estimated by the model flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“This method has been recently implemented using inexpensive and convenient instrumentation such as chairs [102], beds [103], weighing scales [104], and on-body accelerometers [105].”
MethodBallistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
“…of phonocardiography (PCG; sounds from the heart) ( 28 ), seismocardiography (SCG; vibrations of the chest induced by the beating of the heart) ( 29 – 34 ), ballistocardiography (BCG; recoil motions associated with reactions to cardiovascular pressure) ( 28 , 30 , 35 , 36 ), and sounds…”
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Ha, T., Tran, J., Liu, S., Jang, H., Jeong, H., Mitbander, R., Huh, H., Qiu, Y., Duong, J., Wang, R. L., et al. (2019) · Advanced Science · doi:10.1002/advs.201900290 · Cited by 220
Metadata
- Authors
- Castiglioni, P., Faini, A., Parati, G., & Di Rienzo, M.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 3954-3957
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2293235042
- Cited by
- 154
- References
- 0
- FWCI
- 6.13
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Seismocardiography. https://app.cochat.ai/papers/10.1109/iembs.2007.4353199
- The paper
- Castiglioni, P., Faini, A., Parati, G., & Di Rienzo, M. (2007). Wearable Seismocardiography. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4353199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.