Comparison of reflected green light and infrared photoplethysmography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We evaluated the accuracy of pulse rate measurements obtained by reflected green light photoplethysmography (PPG) compared to reflected infrared light photoplethysmography and ECG. The wavelengths of the green and infrared light were 525 and 880 nm, respectively, and experiments were performed at 25 degrees C and at a skin temperature below 15 degrees C. The pulse rate obtained from reflected green light PPG was compared with the ECG RR interval and the pulse rate from reflected infrared PPG. The results indicated a stronger correlation between green PPG and ECG results at both temperatures. These results suggested that reflected green light PPG had an advantage over reflected infrared PPG, especially at temperatures below 15 degrees C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · cited 1×
“The penetration depth of light is dependent on its wavelength [4].”
Cited by
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Jinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
“and multi-wavelength PPG sensing [57], [59], [60].”
A novel sensor for wrist based optical heart rate monitor
Mohapatra, P., Preejith, S. P., & Sivaprakasam, M. (2017) · 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) · doi:10.1109/i2mtc.2017.7969842 · Cited by 19
“Analyzing the effects of penetration depths and potential PPG content in the captured signal at the wrist with respect to the choice of wavelengths, green proves to be the choicest [6].”
Background
Metadata
- Authors
- Maeda, Y., Sekine, M., Tamura, T., Moriya, A., Suzuki, T., & Kameyama, K.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 2270-2272
- OpenAlex
- W2171767692
- Cited by
- 62
- References
- 1
- FWCI
- 3.64
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of reflected green light and infrared photoplethysmography. https://app.cochat.ai/papers/10.1109/iembs.2008.4649649
- The paper
- Maeda, Y., Sekine, M., Tamura, T., Moriya, A., Suzuki, T., & Kameyama, K. (2008). Comparison of reflected green light and infrared photoplethysmography. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2008.4649649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.