A novel sensor for wrist based optical heart rate monitor
Abstract
The growing demands of continuous healthcare and hence physiological monitoring necessitates a system with high reliability and accuracy. Wearable used for continuous cardiological parameter estimation from wrist use reflective photoplethysmography technique that has certain limitations which are imperative. One such constraint is skin pigmentation of the subject. In the present work a sensor module design is proposed addressing to the anomalies due to optical properties of skin. A novel 590 nm (yellow-orange) wavelength based optical system is tailored suitably to maximize the signal quality acquired. The proposed setup is validated on a conglomeration of subjects in terms of age, gender and skin tone. A generous agreement between coherent measures for signal quality shows that the proposed wavelength holds an advantage over its shorter counterpart when subjected to varied skin pigmentation levels. A maximum improvement factor of 71 is observed in case of perfusion index, 31 for pulsatile strength and 3 for SNR. The details of sensor design, experimental setup, validation protocol, observations and inferences drawn from the study are presented.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For Fitzpatrick IV individuals, the perfusion index increased between 1.2 and 7.1 times with the use of 590 nm light, pulsatile strength increased by 1.1 to 3.1 times, and SNR increased by 1.3 to 2.6 times, although no statistical significance analyses were performed.
“For Fitzpatrick IV individuals, the perfusion index increased between 1.2 and 7.1 times with the use of the 590 light, while pulsatile strength increased by 1.1 to 3.1 times and SNR increased by 1.3 to 2.6 times, although no statistical significance analyses were performed [51].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [51]
Mohapatra et al. found that with a multiwavelength PPG device, perfusion index, pulsatile strength, and SNR all increased when data collected with the 590 nm LED were analyzed.
“With 20 subjects ranging from Fitzpatrick II to Fitzpatrick IV, the perfusion index (AC/DC), pulsatile strength, and SNR were all found to increase when data collected with the 590 nm LED were analyzed.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [51]
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · see citing works
Wearable sensors : fundamentals, implementation and applications
Sazonov, E. E., & Neuman, M. R. (2014) · doi:10.1016/c2018-0-01225-6 · Cited by 169 · see citing works
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148 · see citing works
Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals
Jeyhani, V., Mahdiani, S., Peltokangas, M., & Vehkaoja, A. T. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319747 · Cited by 136 · see citing works
Comparison of reflected green light and infrared photoplethysmography
Maeda, Y., Sekine, M., TAMURA, T., Moriya, A., Suzuki, T., & Kameyama, K.-I. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649649 · Cited by 62 · see citing works
A new method for heart rate monitoring during physical exercise using photoplethysmographic signals
Schäck, T., Sledz, C., Muma, M., & Zoubir, A. M. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362868 · Cited by 58 · see citing works
Evaluation of accuracy and reliability of PulseOn optical heart rate monitoring device
Delgado-Gonzalo, R., Parák, J., Tarniceriu, A., Renevey, P., Bertschi, M., & Korhonen, I. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318391 · Cited by 55 · see citing works
E-Healthcare Systems and Wireless Communications: Current and Future Challenges
Watfa, M. K. (2011) · doi:10.4018/978-1-61350-123-8 · Cited by 17 · see citing works
Fabrication of Reflectance Pulse Oximeter with Ring-Shaped Photodiode
Kano, M., Sato, Y., Kanda, K., Fujita, T., Maenaka, K., Kasai, K., & Higuchi, K. (2013) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2013.643 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Sensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272 · see citing works
Explainable AI-based Alzheimer’s prediction and management using multimodal data
Jahan, S., Abu Taher, K., Kaiser, M. S., Mahmud, M., Rahman, M. S., Hosen, A. S. M. S., & Ra, I.-H. (2023) · PLOS ONE · doi:10.1371/journal.pone.0294253 · Cited by 122 · see citing works
Blood pressure measurement using only a smartphone
Frey, L., Menon, C., & Elgendi, M. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00629-2 · Cited by 55 · see citing works
Evaluation of the signal quality of wrist-based photoplethysmography
Pradhan, N., Rajan, S., & Adler, A. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab225a · Cited by 50 · see citing works
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49 · see citing works
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 43 · see citing works
Non-Contact Non-Invasive Heart and Respiration Rates Monitoring with MIMO Radar Sensing
Liu, Q., Guo, H., Xu, J., Wang, H., Kageza, A., AlQarni, S., & Wu, S. (2018) · Globecom · doi:10.1109/glocom.2018.8648106 · Cited by 27 · see citing works
Wallace, B., Harake, T. N. E., Goubran, R. A., Valech, N., & Knoefel, F. D. (2018) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2018.8409727 · Cited by 25 · see citing works
Mohapatra, P., Premkumar, P. S., & Sivaprakasam, M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2786677 · Cited by 20 · see citing works
Self-citationJolly, A., Pandey, V., Sahni, M., León‐Castro, E., & Pérez-Arellano, J.-L. (2025) · Healthcare · doi:10.3390/healthcare13040411 · Cited by 12 · see citing works
Embedded POFBG for Respiratory and Heart Rate Measurement
Qu, H., Liang, W., Chen, X., Tam, H., Min, R., Li, P.-C., & Hu, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3515210 · Cited by 5 · see citing works
Wearable Physical Sensors for Non-invasive Health Monitoring
Nguyen, C. T., Nguyen, T., Dinh, T., Dau, V. T., & Dao, D. V. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_6 · Cited by 4 · see citing works
Assessment of Exercise Capacity in Home Healthcare
Dias, K. J., McPherson, A., Mason, K., Dowling, K., Smith-Beaver, L. P., & Nadler, D. R. (2024) · Home Healthcare Now · doi:10.1097/nhh.0000000000001260 · Cited by 2 · see citing works
Fang, B., Sun, F., Liu, H., Liu, C., & Guo, D. (2020) · Springer eBooks · doi:10.1007/978-981-15-5124-6_1 · Cited by 1 · see citing works
Evaluation of the Signal Quality of Wrist-Based Photoplethysmography
Pradhan, N. (2018) · doi:10.22215/etd/2018-12624 · Cited by 1 · see citing works
Sri, G. G., Fathima, H., Preejith, S. P., & Sivaprakasam, M. (2026) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea69746.2026.11537357
Self-citation
- Authors
- Mohapatra, P., Preejith, S. P., & Sivaprakasam, M.
- Affiliations
- Indian Institute of Technology Madras (IN)
- Indian Institute of Technology Delhi (IN)
- Venue
- 2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
- Publisher
- IEEE
- Published
- 2017-05
- Pages
- 1-6
- ISSN
- 2642-2069 (ISSN-L)
- OpenAlex
- W2734478367
- Cited by
- 19
- References
- 10
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 1 · 2018: 5
- FWCI
- 4.88
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Instrumentation and Measurement Technology Conference (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Computer Science › Signal Processing › Biometric Identification and Security
- Keywords
- wrist-worn sensors, photoplethysmography, skin pigmentation, sensor design, perfusion index, signal-to-noise ratio, physiological monitoring, wearable devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review