Cited by 19Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlBiometric Identification and Security

A novel sensor for wrist based optical heart rate monitor

Mohapatra, Payal, Preejith, S. P., Sivaprakasam, Mohanasankar·2017·2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)

Abstract

The growing demands of continuous healthcare and hence physiological monitoring necessitates a system with high reliability and accuracy. Wearable used for continuous cardiological parameter estimation from wrist use reflective photoplethysmography technique that has certain limitations which are imperative. One such constraint is skin pigmentation of the subject. In the present work a sensor module design is proposed addressing to the anomalies due to optical properties of skin. A novel 590 nm (yellow-orange) wavelength based optical system is tailored suitably to maximize the signal quality acquired. The proposed setup is validated on a conglomeration of subjects in terms of age, gender and skin tone. A generous agreement between coherent measures for signal quality shows that the proposed wavelength holds an advantage over its shorter counterpart when subjected to varied skin pigmentation levels. A maximum improvement factor of 71 is observed in case of perfusion index, 31 for pulsatile strength and 3 for SNR. The details of sensor design, experimental setup, validation protocol, observations and inferences drawn from the study are presented.

Integrity signals

Registry

Crossref · 10.1109/i2mtc.2017.7969842

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For Fitzpatrick IV individuals, the perfusion index increased between 1.2 and 7.1 times with the use of 590 nm light, pulsatile strength increased by 1.1 to 3.1 times, and SNR increased by 1.3 to 2.6 times, although no statistical significance analyses were performed.

    “For Fitzpatrick IV individuals, the perfusion index increased between 1.2 and 7.1 times with the use of the 590 light, while pulsatile strength increased by 1.1 to 3.1 times and SNR increased by 1.3 to 2.6 times, although no statistical significance analyses were performed [51].”
  • Mohapatra et al. found that with a multiwavelength PPG device, perfusion index, pulsatile strength, and SNR all increased when data collected with the 590 nm LED were analyzed.

    “With 20 subjects ranging from Fitzpatrick II to Fitzpatrick IV, the perfusion index (AC/DC), pulsatile strength, and SNR were all found to increase when data collected with the 590 nm LED were analyzed.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Mohapatra, P., Preejith, S. P., & Sivaprakasam, M.
Affiliations
  • Indian Institute of Technology Madras (IN)
  • Indian Institute of Technology Delhi (IN)
Venue
2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
Publisher
IEEE
Published
2017-05
Pages
1-6
ISSN
2642-2069 (ISSN-L)
OpenAlex
W2734478367
Cited by
19
References
10
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 1 · 2018: 5
FWCI
4.88
Type
conference paper
Language
en
Open access
closed
Locations
IEEE International Instrumentation and Measurement Technology Conference (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Computer Science › Signal Processing › Biometric Identification and Security
Keywords
wrist-worn sensors, photoplethysmography, skin pigmentation, sensor design, perfusion index, signal-to-noise ratio, physiological monitoring, wearable devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›