CoChat

Benchmarking of a full-body inertial motion capture system for clinical gait analysis

Cloete, Teunis, Scheffer, Cornie · 2008 · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 129

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In order for gait analysis to be established as part of routine clinical diagnoses, an accurate, flexible and user-friendly motion capture system is required. Commonly used optical, mechanical and acoustic systems offer acceptable accuracy and repeatability, but are often expensive and restricted to laboratory use. Inertial motion capture has seen great innovation in the last few years, but the technology is not yet considered mature enough for clinical gait analysis. In this paper we compare the kinematic reliability of inertial motion capture with optical motion capture during routine gait studies of eight able-bodied subjects. The root mean squared, RMS, and coefficient of correlation, R, was used to compare data sets. Saggital plane joint angles in the knee and hip compared very well. Corresponding transverse and frontal plane values were moderately accurate. The ankle joint angles calculated from the two systems were less accurate. This was believed to be due to the use of different rotation axis orientations used for calculation of angular rotations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2008.4650232

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 129

Metadata

Authors
Cloete, T., & Scheffer, C.
Venue
2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2008-08
Volume
2008
Pages
4579-4582
OpenAlex
W2132089121
Cited by
129
References
2
FWCI
11.63
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.