Measurement of rectus femoris muscle velocities during patellar tendon jerk using vector tissue doppler imaging

Open access
Sikdar, S., Lebiedowska, M., Eranki, A., Garmirian, L., Damiano, D.·2009·2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

We have developed a vector tissue Doppler imaging (TDI) system based on a clinical scanner that can be used to measure muscle velocities independent of the direction of motion. This method overcomes the limitations of conventional Doppler ultrasound, which can only measure velocity components along the ultrasound beam. In this study, we utilized this method to investigate the rectus femoris muscle velocities during a patellar tendon jerk test. Our goal was to investigate whether the muscle elongation velocities during a brisk tendon tap fall within the normal range of velocities that are expected due to rapid stretch of limb segments. In a preliminary study, we recruited six healthy volunteers (three men and three women) following informed consent. The stretch reflex response to tendon tap was evaluated by measuring: (1) the tapping force using an accelerometer instrumented to the neurological hammer (2) the angular velocities of the knee extension and flexion using a electrogoniometer (3) reflex activation using electromyography (EMG) and (4) muscle elongation, extension and flexion velocities using vector TDI. The passive joint angular velocity was linearly related to the passive muscle elongation velocity (R(2)=0.88). The maximum estimated joint angular velocity corresponding to muscle elongation due to tendon tap was less than 8.25 radians/s. This preliminary study demonstrates the feasibility of vector TDI for measuring longitudinal muscle velocities and indicates that the muscle elongation velocities during a clinical tendon tap test are within the normal range of values for rapid limb stretch encountered in daily life. With further refinement, vector TDI could become a powerful method for quantitative evaluation of muscle motion in musculoskeletal disorders.

Integrity signals

Registry

Crossref · 10.1109/iembs.2009.5332500

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

0 of 10 cited sources checked · 0 supported · 0 flagged

  • Findingown data

    The maximum error was 16% for the vector Doppler method.

    “The maximum error was 16%.”
    Quote in the paperSubstantial claim
  • Findingown data

    The maximum estimated joint angular velocity corresponding to muscle elongation due to tendon tap was less than 8.25 radians/s.

    “The maximum estimated joint angular velocity corresponding to muscle elongation due to tendon tap was less than 8.25 radians/s.”
    • Also stated in: § B. Estimation of elongation, reflex extension and passive flexion velocities · hedged
      “The estimated joint angular velocity corresponding to the muscle elongation due to tendon tap was less than 8.25 radians/s (Fig. 3(B)).”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The transfer function between passive knee angular velocity and passive rectus femoris elongation velocity applies to the muscle elongation produced by a tendon tap.
  • Findingown data

    Mean absolute error was 9% in the velocity magnitude estimated using the vector Doppler method compared to the manufacturer specified velocity of the string.

    “Mean absolute error was 9% in the velocity magnitude estimated using our method compared to the manufacturer specified velocity of the string.”
    Quote in the paperSubstantial claim
  • Findingown data

    The maximum error using conventional 1D Doppler ultrasound using the same transmit and receive aperture sizes with the string at 60° to the transducer was 22%.

    “The maximum error using conventional 1D Doppler ultrasound using the same transmit and receive aperture sizes with the string at 60° to the transducer was 22%.”
    Quote in the paperSubstantial claim
  • Findingreasoning

    A vector tissue Doppler imaging (TDI) system based on a clinical scanner has been developed that can measure muscle velocities independent of the direction of motion.

    “We have developed a vector tissue Doppler imaging (TDI) system based on a clinical scanner that can be used to measure muscle velocities independent of the direction of motion.”
    • Also stated in: § I. Introduction · plain
      “We have developed a vector TDI system by electronically splitting a linear array transducer into multiple sub-apertures that can be electronically steered to estimate motion in multiple directions and reconstruct both the velocity magnitude and direction in an angle-independent manner.”
    • Also stated in: § V. CONCLUSION · plain
      “We have developed a vector TDI system based on a clinical ultrasound scanner for measuring longitudinal muscle velocities.”
    Quote in the paperSubstantial claim
  • May combine two claims. 8
  • Classified as probably not a substantial claim. 9
  • May combine two claims.

    Findingnone given

    The second peak occurs after the EMG signal indicating activation of reflex extension and corresponds to the reflex muscle extension velocity (νshreflex).

    “The second peak occurs after the EMG signal indicating activation of reflex extension and corresponds to the reflex muscle extension velocity (νshreflex).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingnone given

    The first velocity peak occurs immediately after the hammer impact and corresponds to the elongation of the muscle in response to the tendon tap (νeltap).

    “The first velocity peak occurs immediately after the hammer impact and corresponds to the elongation of the muscle in response to the tendon tap (νeltap).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The direction of νelpassive is the same as νeltap and occurs predominantly in the lateral direction along the length of the rectus femoris.

    “In Figure 2(E), note that the direction of νelpassive is the same as νeltap as expected, and occurs predominantly in the lateral direction (blue trace) along the length of the rectus femoris.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Sensitivity to tendon tap varied across cases, with high correlation between muscle elongation and hammer acceleration for cases 4 and 5 (R2=0.71 and 0.96) and lower correlation for cases 1, 2, 3, and 6 (R2=0.03, 0.33, 0.25, and 0.56).

    “Some cases had high sensitivity to tendon tap, with a high correlation between muscle elongation and hammer acceleration (R2 =0.71 and 0.96, for cases 4 and 5 respectively), whereas other cases had lower sensitivity (R2 =0.03, 0.33, 0.25 and 0.56, for cases 1,2,3 and 6 respectively).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisereasoning

    Conventional Doppler ultrasound can only measure velocity components along the ultrasound beam, which limits its utility for estimating muscle velocities because muscle motion is often longitudinal along the skin surface.

    “This method overcomes the limitations of conventional Doppler ultrasound, which can only measure velocity components along the ultrasound beam.”
    • Also stated in: § I. Introduction · plain
      “This poses a challenge for conventional Doppler methods, since they can only estimate the velocity component along the direction of the propagating ultrasound beam, which is perpendicular to the skin surface.”
    • Also stated in: § IV. DISCUSSION · plain
      “Conventional Doppler ultrasound can only estimate velocity components along the direction of propagation of the ultrasound beam.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Premisecitation

    Tissue Doppler imaging (TDI) is routinely used for estimating velocities of cardiac muscle and can potentially be used for estimating skeletal muscle velocities as well.

    “Tissue Doppler imaging (TDI) is routinely used for estimating velocities of cardiac muscle and can potentially be used for estimating skeletal muscle velocities as well [4, 5].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [4] source

      Not checked in the free run.

    • cites [5] source

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Premisecitation

    The vector Doppler method is based on estimating the velocity vector from measurements taken from two or more independent directions.

    “The vector Doppler method is based on estimating the velocity vector from the measurements taken from two or more independent directions [7].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [7] source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    In response to tendon tap, both rectus femoris and vastus lateralis muscles are activated through monosynaptic networks.

    “Previous studies have demonstrated that in response to tendon tap, both rectus femoris and vastus lateralis muscles are activated through monosynaptic networks [6].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [6] source

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Study design and conductnone given

    The ultrasound data acquisition was synchronized with the instrumented neurological hammer, electrogoniometer and EMG using an external trigger output from the ultrasound system.

    “The ultrasound data acquisition was synchronized with the instrumented neurological hammer, electrogoniometer and EMG using an external trigger output from the ultrasound system.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    The ultrasound transducer was externally clamped and the subject was seated on a fixed surface to minimize relative motion between the knee joint and the ultrasound probe due to the knee jerk.

    “In our studies, the ultrasound transducer was externally clamped and the subject was seated on a fixed surface to minimize relative motion between the knee joint and the ultrasound probe due to the knee jerk.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    Six healthy volunteers provided informed consent to participate in the study.

    “Six healthy volunteers (three men and three women, age range 20–29 years) were recruited from the staff and students at George Mason University and provided informed consent to participate in the study.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Study design and conductreasoning

    A variance correction term was included in the velocity estimate so that the velocity estimates were close to the maximum Doppler shift frequencies.

    “We included a variance correction term in our velocity estimate, so that the velocity estimates were close to the maximum Doppler shift frequencies.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    B-mode imaging was used to ensure that the center of the rectus femoris muscle was approximately located at the expected beam overlap region.

    “B-mode imaging was used to ensure that the center of the rectus femoris muscle was approximately located at the expected the beam overlap region (as shown in Figure 1).”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The velocity estimates were calibrated using a string phantom.

    “The velocity estimates were calibrated using a string phantom (CIRS Inc. Norfolk, VA).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisereasoning

    The B-mode ultrasound method for measuring fascicle stretch velocities has limitations because the entire fascicle length for many muscle groups is difficult to measure due to the limited field of view of ultrasound and the measurements are sensitive to any movement of the transducer.

    “This method has several limitations since the entire fascicle length for many muscle groups is difficult to measure due to the limited field of view of ultrasound and the measurements are sensitive to any movement of the transducer.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    The Institutional Review Board approved all the study procedures.

    “Our Institutional Review Board approved all the study procedures.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    Other researchers have used ultrasound to measure fascicle stretch velocities during stretch reflex response.

    “Other researchers have used ultrasound to measure fascicle stretch velocities during stretch reflex response [9] [10].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [9] source

      Not checked in the free run.

    • cites [10] source

      Not checked in the free run.

17 of 17
  • The paper relies on this without support.

    The transfer function between passive knee angular velocity and passive rectus femoris elongation velocity applies to the muscle elongation produced by a tendon tap.

    “We calculated the transfer function between (ωelpassive) and (νelpassive). The equivalent knee angular velocity (ωeltap) corresponding to the elongation of rectus femoris muscle during standard tendon tap can then be estimated from νeltap as follows: (1)ωelpassive=A×νelpassive+B⇒ωeltap=A×νeltap+B”
  • The paper relies on this without support.

    Stimuli like the tendon tap are not encountered during normal movement activities.

    “Stimuli like the tendon tap are not encountered during normal movement activities.”
  • The paper relies on this without support.

    It is not known whether the muscle lengthening velocity during a tendon tap approaches or exceeds those produced by the rapid stretch of a limb segment, or how it compares to the range of knee angular velocities encountered during functional movements.

    “It is not known whether the muscle lengthening velocity during a tendon tap approaches or exceeds those produced by the rapid stretch of a limb segment, or how it compares to the range of knee angular velocities encountered during functional movements.”
  • The paper relies on this without support.

    Currently, there is no reliable method to directly measure the muscle elongation and activation velocities.

    “Currently, there is no reliable method to directly measure the muscle elongation and activation velocities.”
4 of 4

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sikdar, S., Lebiedowska, M., Eranki, A., Garmirian, L., & Damiano, D.
Affiliations
  • George Mason University (US)
  • National Institutes of Health (US)
Venue
2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2009-09
Volume
143
Pages
2963-2966
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2129097239
Cited by
13
References
10
Citations by year
2024: 1 · 2022: 1 · 2015: 1 · 2013: 3 · 2012: 1
FWCI
6.05
Type
conference paper
Language
en
Open access
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • NIH Clinical Center (ZIACL060017)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
rectus femoris, muscle velocity, stretch reflex, knee angular velocity, passive joint motion, electromyography, musculoskeletal disorders
MeSH terms
Adult, Algorithms, Electromyography, Female, Humans, Image Processing, Computer-Assisted, Male, Neuromuscular Diseases, Reflex, Reflex, Stretch, Range of Motion, Articular, Patellar Ligament, Muscle, Skeletal, Ultrasonography, Doppler, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-11.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-11.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review