Non-contact respiratory rate measurement validation for hospitalized patients
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the first clinical results for validating the accuracy of respiratory rate obtained for hospitalized patients using a non-contact, low power 2.4 GHz Doppler radar system. Twenty-four patients were measured in this study. The respiratory rate accuracy was benchmarked against the respiratory rate obtained using Welch Allyn Propaq Encore model 242, the Embla Embletta system with Universal XactTrace respiratory effort sensor and Somnologica for Embletta software, and by counting chest excursions. The 95% limits of agreement between the Doppler radar and reference measurements fall within +/-5 breaths per minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgetts, T. J., Kenward, G., Vlachonikolis, I. G., Payne, S., & Castle, N. (2002) · Resuscitation · doi:10.1016/s0300-9572(02)00100-4 · Cited by 355 · cited 1×
“In fact, a sudden change in respiratory rate is one of the strongest predictors of mortality [2]-[3].”
Background
Cited by
A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2256924 · Cited by 821
Self-citationA Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems
Li, C., Peng, Z., Huang, T.-Y., Fan, T., Wang, F.-K., Horng, T.-S., Munoz-Ferreras, J.-M., Gomez-Garcia, R., Ran, L., & Lin, J. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2650911 · Cited by 372
RF Sensing Technologies for Assisted Daily Living in Healthcare: A Comprehensive Review
Shah, S. A., & Fioranelli, F. (2019) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/maes.2019.2933971 · Cited by 172
“Several papers have been published focusing on accurately measuring the respiration rates [23], [24] and the instantaneous vital sign rates, which are related to physiological dynamics, are important indicators of human health condition [25], [26].”
BackgroundAlgorithms for Monitoring Heart Rate and Respiratory Rate From the Video of a User’s Face
Sanyal, S., & Nundy, K. K. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2818687 · Cited by 125
“Non-contact measurement techniques usually utilize ultrasound [28] or microwave [29] readings.”
BackgroundPandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
“For both inter-subject and intra-subject variability measurements, the limits of agreement fall within the clinically acceptable range shown in published literature of ± 4 to ± 6 bpm (Droitcour et al 2009, Lim et al 2002).”
Method
Metadata
- Authors
- Droitcour, A. D., Seto, T. B., Park, B.-K., Yamada, S., Vergara, A., El Hourani, C., Shing, T., Yuen, A., Lubecke, V. M., & Boric-Lubecke, O.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 4812-4815
- OpenAlex
- W2142797701
- Cited by
- 133
- References
- 1
- FWCI
- 11.13
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-contact respiratory rate measurement validation for hospitalized patients. https://app.cochat.ai/papers/10.1109/iembs.2009.5332635
- The paper
- Droitcour, A. D., Seto, T. B., Park, B.-K., Yamada, S., Vergara, A., El Hourani, C., Shing, T., Yuen, A., Lubecke, V. M., & Boric-Lubecke, O. (2009). Non-contact respiratory rate measurement validation for hospitalized patients. 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2009.5332635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.