iFall: An android application for fall monitoring and response
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Injuries due to falls are among the leading causes of hospitalization in elderly persons, often resulting in a rapid decline in quality of life or death. Rapid response can improve the patients outcome, but this is often lacking when the injured person lives alone and the nature of the injury complicates calling for help. This paper presents an alert system for fall detection using common commercially available electronic devices to both detect the fall and alert authorities. We use an Android-based smart phone with an integrated tri-axial accelerometer. Data from the accelerometer is evaluated with several threshold based algorithms and position data to determine a fall. The threshold is adaptive based on user provided parameters such as: height, weight, and level of activity. The algorithm adapts to unique movements that a phone experiences as opposed to similar systems which require users to mount accelerometers to their chest or trunk. If a fall is suspected a notification is raised requiring the user's response. If the user does not respond, the system alerts pre-specified social contacts with an informational message via SMS. If a contact responds the system commits an audible notification, automatically connects, and enables the speakerphone. If a social contact confirms a fall, an appropriate emergency service is alerted. Our system provides a realizable, cost effective solution to fall detection using a simple graphical interface while not overwhelming the user with uncomfortable sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
Bourke, A. K., O’Brien, J. V., & Lyons, G. M. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.09.012 · Cited by 821
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615
A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
Bourke, A. K., & Lyons, G. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.12.001 · Cited by 509
Staying connected while on the move: Cell phone use and social connectedness
Wei, R., & Lo, V.-H. (2006) · New Media & Society · doi:10.1177/1461444806059870 · Cited by 493
Wearable Sensors for Reliable Fall Detection
Chen, J., Kwong, K., Chang, D., Luk, J., & Bajcsy, R. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1617246 · Cited by 443
A Smart and Passive Floor-Vibration Based Fall Detector for Elderly
Alwan, M., Rajendran, P. J., Kell, S., Mack, D., Dalal, S., Wolfe, M., & Felder, R. (2006) · 2006 2nd International Conference on Information & Communication Technologies · doi:10.1109/ictta.2006.1684511 · Cited by 402
Peterson, E. W., Cho, C. C., & Finlayson, M. L. (2007) · Multiple Sclerosis Journal · doi:10.1177/1352458507079260 · Cited by 258
A Customized Human Fall Detection System Using Omni-Camera Images and Personal Information
Miaou, S.-G., Sung, P.-H., & Huang, C.-Y. (2006) · 1st Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare, 2006. D2H2. · doi:10.1109/ddhh.2006.1624792 · Cited by 253
Lee, T., & Mihailidis, A. (2005) · Journal of Telemedicine and Telecare · doi:10.1258/1357633054068946 · Cited by 237
Activity summarisation and fall detection in a supportive home environment
Nait-Charif, H., & McKenna, S. J. (2004) · Proceedings of the 17th International Conference on Pattern Recognition, 2004. ICPR 2004. · doi:10.1109/icpr.2004.1333768 · Cited by 223
Determination of simple thresholds for accelerometry-based parameters for fall detection
Kangas, M., Konttila, A., Winblad, I., & Jamsa, T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352552 · Cited by 202
Hwang, J. Y., Kang, J. M., Jang, Y. W., & Kim, H. C. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403643 · Cited by 201
An acoustic fall detector system that uses sound height information to reduce the false alarm rate
Popescu, M., Li, Y., Skubic, M., & Rantz, M. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4650244 · Cited by 189
The design of a practical and reliable fall detector for community and institutional telecare
Doughty, K., Lewis, R., & Mcintosh, A. (2000) · Journal of Telemedicine and Telecare · doi:10.1258/1357633001934483 · Cited by 185
A smart fall and activity monitor for telecare applications
Williams, G., Doughty, K., Cameron, K., & Bradley, D. A. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.747074 · Cited by 150
Fall detection by embedding an accelerometer in cellphone and using kfd algorithm
Zhang, T., Wang, J., Liu, P., & Hou, J. (2006) · Cited by 121
Thomas, K. E., Stevens, J. A., Sarmiento, K., & Wald, M. (2008) · Journal of Safety Research · doi:10.1016/j.jsr.2008.05.001 · Cited by 91
A dynamic motion pattern analysis approach to fall detection
Luo, S., & Hu, Q. (2005) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2004.1454088 · Cited by 74
Garment-based detection of falls and activities of daily living using 3-axis MEMS accelerometer
Nyan, M. N., Tay, F. E. H., Manimaran, M., & Seah, K. H. W. (2006) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/34/1/175 · Cited by 56
Automatic Fall Detection and Activity Monitoring for Elderly
Fraisse, P., Pérolle, G., Mavros, M., & Etxeberría, I. (2007) · HAL · Cited by 45
Using Smart Sensors and a Camera Phone to Detect and Verify the Fall of Elderly Persons
Hansen, T. R., Eklund, J., Sprinkle, J. M., Bajcsy, R. K., & Sastry, S. (2005) · Cited by 31
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
A Systematic Review of Healthcare Applications for Smartphones
Mosa, A. S. M., Yoo, I., & Sheets, L. (2012) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-12-67 · Cited by 1,184
“Sposaro and Tyson (2009) [81] demonstrated the costeffectiveness of iFall, which utilizes the inbuilt tri-axial accelerometer of an Android phone, processes the data on the phone, and prompts the user in cases of possible falls.”
BackgroundChallenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
Human fall detection on embedded platform using depth maps and wireless accelerometer
Kwolek, B., & Kepski, M. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.09.005 · Cited by 650
“For instance, in iFall application [14], data from the accelerometer is evaluated using several threshold-based algorithms and position data to determine the person’s fall.”
MethodMobile Phone Sensing Systems: A Survey
Khan, W. Z., Xiang, Y., Aalsalem, M. Y., & Arshad, Q. (2013) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2012.031412.00077 · Cited by 557
Metadata
- Authors
- Sposaro, F., & Tyson, G.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 6119-6122
- OpenAlex
- W2096962968
- Cited by
- 317
- References
- 21
- FWCI
- 15.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.