Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS: To establish gait analysis as part of routine clinical diagnoses, physicians demand accurate and flexible motion capture (Mocap). Currently, popular optical, mechanical and acoustic Mocap systems offer acceptable repeatability, but fall short of the spatial and economic benefits accompanying inertial motion capture (IMC). However, IMC is considered adolescent due to limited testing in gait analysis. This paper aims to address this hindrance through within-day and between test day repeatability studies. METHODS: To determine the repeatability of IMC, routine gait studies were done on 30 able-bodied males. Repeatability was quantified using the coefficient of multiple determination (CMD) and the coefficient of multiple correlation (CMC). RESULTS: IMC-recorded kinematics were highly repeatable for within-day (CMD: 0.786-0.984 or CMC: 0.881-0.992) and between-day trials (CMD: 0.771-0.991 or CMC: 0.872-0.995). The results compare well to those from similar repeatability studies in the literature based on optical Mocap systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00087-3 · Cited by 532
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“quantities directly related to the motion and orientation of rigid bodies to which the sensors are attached [ 5 ].”
BackgroundDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189
Cited by
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314
“We are aware of only one study that has demonstrated a high within-day and between-day repeatability in 3D joint angle measurements during overground walking (Cloete and Scheffer 2010); validation with an existing camera-based motion capture system has not been examined.”
BackgroundReliability and validity of instrumented soccer equipment
Akins, J. S., Heebner, N. R., Lovalekar, M., & Sell, T. C. (2015) · Journal of Applied Biomechanics · doi:10.1123/jab.2014-0191 · Cited by 17
Callaghan, S. J., Lockie, R. G., Andrews, W. A., Yu, W., Chipchase, R. F., & Nimphius, S. (2019) · Sports · doi:10.3390/sports7090200 · Cited by 13
Metadata
- Authors
- Cloete, T., & Scheffer, C.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 5125-5128
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2164165374
- Cited by
- 51
- References
- 3
- FWCI
- 8.11
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis. https://app.cochat.ai/papers/10.1109/iembs.2010.5626196
- The paper
- Cloete, T., & Scheffer, C. (2010). Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5626196
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.