A transparent μECoG array for simultaneous recording and optogenetic stimulation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper we report for the first time the design, fabrication and characterization of an optically transparent electrode array for micro-electrocorticography. We present a 49-channel μECoG array with an electrode pitch of 800 μm and a 16-channel linear μECoG array with an electrode pitch of 200 μm. The backing material was Parylene C. Transparent, sputtered indium tin oxide (ITO) was used in conjunction with e-beam evaporated gold to fabricate the electrodes. We provide electrochemical impedance characterization and light transmission data for the fabricated devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Oscillatory phase coupling coordinates anatomically dispersed functional cell assemblies
Canolty, R. T., Ganguly, K., Kennerley, S. W., Cadieu, C. F., Koepsell, K., Wallis, J. D., & Carmena, J. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1008306107 · Cited by 292
Cited by
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Kuzum, D., Takano, H., Shim, E., Reed, J. C., Juul, H., Richardson, A. G., de Vries, J., Bink, H., Dichter, M. A., Lucas, T. H., et al. (2014) · Nature Communications · doi:10.1038/ncomms6259 · Cited by 546
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
“Other recent work suggests that transparent flexible electrodes based on graphene (Kuzum et al., 2014) and inorganic alternatives such as indium tin oxide (Ledochowitsch et al., 2011), can offer excellent measurement capabilities with options in simultaneous optical imaging or stimulation.”
BackgroundKwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Metadata
- Authors
- Ledochowitsch, P., Olivero, E., Blanche, T., & Maharbiz, M. M.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 2937-2940
- OpenAlex
- W2040015079
- Cited by
- 64
- References
- 2
- FWCI
- 10.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A transparent μECoG array for simultaneous recording and optogenetic stimulation. https://app.cochat.ai/papers/10.1109/iembs.2011.6090808
- The paper
- Ledochowitsch, P., Olivero, E., Blanche, T., & Maharbiz, M. M. (2011). A transparent μECoG array for simultaneous recording and optogenetic stimulation. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6090808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.