CoChat

A subject-independent brain-computer interface based on smoothed, second-order baselining

Reuderink, B., Farquhar, J., Poel, M., Nijholt, A. · 2011 · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 54

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A brain-computer interface (BCI) enables direct communication from the brain to devices, bypassing the traditional pathway of peripheral nerves and muscles. Traditional approaches to BCIs require the user to train for weeks or even months to learn to control the BCI. In contrast, BCIs based on machine learning only require a calibration session of less than an hour before the system can be used, since the machine adapts to the user's existing brain signals. However, this calibration session has to be repeated before each use of the BCI due to inter-session variability, which makes using a BCI still a time-consuming and an error-prone enterprise. In this work, we present a second-order baselining procedure that reduces these variations, and enables the creation of a BCI that can be applied to new subjects without such a calibration session. The method was validated with a motor-imagery classification task performed by 109 subjects. Results showed that our subject-independent BCI without calibration performs as well as the popular common spatial patterns (CSP)-based BCI that does use a calibration session.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2011.6091139

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 9

  1. 10.1109/TBME.2004.827072 · DOI · Paper page
  2. goldberger, 2000, PhysioBank, physiotoolkit, and physionet, Circulation, 101, 10.1161/01.CIR.101.23.e215 · DOI · Paper page
  3. 10.1371/journal.pone.0002967 · DOI · Paper page
  4. wolpaw, 2002, Brain-computer interfaces for communication and control, Clinical Neurophysiology, 113, 767, 10.1016/S1388-2457(02)00057-3 · DOI · Paper page
  5. 10.1016/0013-4694(91)90163-X · DOI · Paper page
  6. 10.1109/IEMBS.2009.5334126 · DOI · Paper page
  7. 10.1016/j.neunet.2009.06.003 · DOI · Paper page
  8. tomioka, 2006, Adapting spatial filtering methods for nonstationary BCIs, Proceedings of 2006 Workshop on Information-Based Induction Sciences
  9. 10.1016/j.neunet.2009.06.035 · DOI

Cited by

See all 54

Metadata

Authors
Reuderink, B., Farquhar, J., Poel, M., & Nijholt, A.
Venue
2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2011-08
Volume
2011
Pages
4600-4604
OpenAlex
W2124610677
Cited by
54
References
4
FWCI
7.11
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A subject-independent brain-computer interface based on smoothed, second-order baselining. https://app.cochat.ai/papers/10.1109/iembs.2011.6091139
The paper
Reuderink, B., Farquhar, J., Poel, M., & Nijholt, A. (2011). A subject-independent brain-computer interface based on smoothed, second-order baselining. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6091139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.