CoChat

Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays

Clark, G. A., Ledbetter, N. M., Warren, D. J., Harrison, R. R. · 2011 · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 72

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Recording and stimulation via high-count penetrating microelectrode arrays implanted in peripheral nerves may help restore precise motor and sensory function after nervous system damage or disease. Although previous work has demonstrated safety and relatively successful stimulation for long-term implants of 100-electrode Utah Slanted Electrode Arrays (USEAs) in feline sciatic nerve [1], two major remaining challenges were 1) to maintain viable recordings of nerve action potentials long-term, and 2) to overcome contamination of unit recordings by myoelectric (EMG) activity in awake, moving animals. In conjunction with improvements to USEAs themselves, we have redesigned several aspects of our USEA containment and connector systems. Although further increases in unit yield and long-term stability remain desirable, here we report considerable progress toward meeting both of these goals: We have successfully recorded unit activity from USEAs implanted intrafascicularly in sciatic nerve for periods up to 4 months (the terminal experimental time point), and we have developed a containment system that effectively eliminates or substantially reduces EMG contamination of unit recordings in the moving animal. In addition, we used a 100-channel wireless recording integrated circuit attached to implanted USEAs to transmit broadband or spike-threshold data from nerve. Neural data thusly obtained during imposed limb movements were decoded blindly to drive a virtual prosthetic limb in real time. These results support the possibility of using USEAs in peripheral nerves to provide motor control and cutaneous or proprioceptive sensory feedback in individuals after limb loss or spinal cord injury.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2011.6091149

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 72

Metadata

Authors
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R.
Venue
2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2011-08
Volume
2011
Pages
4641-4644
OpenAlex
W2146505979
Cited by
72
References
6
FWCI
13.64
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays. https://app.cochat.ai/papers/10.1109/iembs.2011.6091149
The paper
Clark, G. A., Ledbetter, N. M., Warren, D. J., & Harrison, R. R. (2011). Recording sensory and motor information from peripheral nerves with Utah Slanted Electrode Arrays. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6091149

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.