D-Q current signature based single winding open fault detection for SM-PMAC machine drives
The DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Abstract
Surface Mount Permanent Magnet AC (SM-PMAC) machines are widely utilized in various applications due to their unique advantages. Transportation industry (automotive and aviation ) is one of the major industries gaining interest in applications with PMAC machines due to increasing demand in fuel economy. Fault detection capability provides an additional level of reliability in all applications involving electric machines and, more specifically applications involving safety of consumers, operators or passengers. Open phase fault is one type of fault that could occur in a PMAC machine drive. A novel method of open single phase detection is proposed to overcome drawbacks in existing open single phase detection algorithms. The proposed method is based on the quadrature and direct axis current (lqsr& Idsr) behavior during the fault. Further, a simpler open phase/open winding fault simulation technique is presented for a SM-PMSM machine. Performance of fault detection scheme was verified through actual implementation on motor generator setup with Hardware-In-Loop (HIL) test capability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“When the PMSM is healthy the ratio is close to infinity (d-axis component close to zero), while the FI is close to zero.When the machine is faulty, the FI is no longer zero.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [184]
In the citing paper
“When a predefined threshold is exceeded the decision about the fault is made.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [184]
In the citing paper
“The FI relies on the ratio of real quadrature to direct axis components.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [184]
In the citing paper
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [184]
In the citing paper
“These methods can be also classified as modelfree [184], [254]- [257], [261]- [263], [267]- [273] and modelbased methods [252], [258]- [260], [264], [265].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [184]
Citations
Cites
Analysis of Electric Machinery and Drive Systems
Krause, P. C., Wasynczuk, O., & Sudhoff, S. D. (2002) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544167 · Cited by 2,314
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Control Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
A strategy to isolate the switching device fault of a current regulated motor drive
Fu, J.-R., & Lipo, T. A. (2002) · Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting · doi:10.1109/ias.1993.299023 · Cited by 101
Open phase faults detection in PMSM drives based on current signature analysis
Khlaief, A., Boussak, M., & Gossa, M. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5607977 · Cited by 66
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zigliotto, M., & Zordan, M. (2002) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.1998.724292 · Cited by 34
Gajanayake, C. J., Bhangu, B., Nadarajan, S., & Jayasinghe, S. G. (2011) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2011.6147371 · Cited by 33
The simulation of brushless DC drive failures
Wallace, A. K., & Spée, R. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1988.18134 · Cited by 27
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“A simple and fast diagnostic method for single open phase fault detection based on control structure signals has been first proposed in [184] and further developed in [185].”
MethodD-Q Current Signature-Based Faulted Phase Localization for SM-PMAC Machine Drives
Kuruppu, S. S., & Kulatunga, N. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334652 · Cited by 51
Self-citationPhase Loss Detection Using Current Signals: A Review
Dianov, A., & Anuchin, A. (2021) · IEEE Access · doi:10.1109/access.2021.3105483 · Cited by 39
A Novel Phase Loss Detection Method for Low-Cost Motor Drives
Dianov, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3143822 · Cited by 27
Electric Machine Differential For Vehicle Traction Control And Stability Control
Kuruppu, S. S. (2013) · Purdue e-Pubs (Purdue University System) · Cited by 1
Self-citation
Metadata
- Authors
- Kuruppu, S. S., & Kulatunga, N. A.
- Affiliations
- Purdue University West Lafayette (US)
- ORCID
- Kuruppu, Sandun S.
- Venue
- 2013 International Electric Machines & Drives Conference
- Publisher
- IEEE
- Published
- 2013-05
- Pages
- 1343-1347
- OpenAlex
- W2161779850
- Cited by
- 5
- References
- 16
- Citations by year
- 2026: 1 · 2022: 2 · 2021: 1 · 2014: 1
- FWCI
- 0.41
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Electric Machines & Drives Conference (IEMDC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- permanent magnet synchronous motor, fault signatures, motor-generator, hardware-in-the-loop testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.