The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Abstract
The first energetically autonomous lower extremity exoskeleton capable of carrying a payload has been demonstrated at U.C. Berkeley. This paper summarizes the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX). The anthropomorphically-based BLEEX has seven degrees of freedom per leg, four of which are powered by linear hydraulic actuators. The selection of the degrees of freedom and their ranges of motion are described. Additionally, the significant design aspects of the major BLEEX components are covered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stair ascent and descent at different inclinations
Riener, R., Rabuffetti, M., & Frigo, C. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00162-x · Cited by 744
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Self-citationWoodson, W. E. (1981) · Cited by 589
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Upper and lower extremity robotic devices for rehabilitation and for studying motor control
Hesse, S., Schmidt, H., Werner, C., & Bardeleben, A. (2003) · Current Opinion in Neurology · doi:10.1097/00019052-200312000-00010 · Cited by 369
Human Robot Interaction via the Transfer of Power and Information Signals
Kazerooni, H. (1990) · IEEE Trans. · Cited by 362
Self-citationPower Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
Human-robot interaction via the transfer of power and information signals
Kazerooni, H. (1990) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.52555 · Cited by 338
Self-citationOn the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 3×
“9 MPa (1000 psi), the BLEEX actuators are sized to provide the joint torques seen in CGA data [24].”
BackgroundMethodInfluentialSelf-citationDevelopment of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
Development of power assisting suit for assisting nurse labor
YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.703 · Cited by 169 · cited 1×
“In Japan, the Kanagawa Institute of Technology has developed a full body “wearable power suit”, powered by unique pneumatic actuators [7].”
BackgroundMakinson, B. J. (1971) · Defense Technical Information Center (DTIC) · doi:10.21236/ad0724797 · Cited by 142
Predicting the intended motion with EMG signals for an exoskeleton orthosis controller
Fleischer, C., Reinicke, C., & Hommel, G. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545504 · Cited by 134
Kazerooni, H., & Guo, J. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899068 · Cited by 119
Self-citationThe human power amplifier technology at the University of California, Berkeley
Kazerooni, H. (1996) · Robotics and Autonomous Systems · doi:10.1016/s0921-8890(96)00045-0 · Cited by 105
Self-citationDynamics and Control of Robotic Systems Worn by Humans
Kazerooni, H., & Mahoney, S. L. (1991) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2896421 · Cited by 91
Self-citationKirtley, C. (2006) · Medical Entomology and Zoology · Cited by 73
Driven gait orthosis to do locomotor training of paraplegic patients
Colombo, G., Jorg, M., & Dietz, V. (2002) · Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143) · doi:10.1109/iembs.2000.901556 · Cited by 72
Hybrid hydraulic-electric power unit for field and service robots
Amundson, K., Raade, J., Harding, N., & Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545452 · Cited by 55
Self-citationMonopropellant-Driven Free Piston Hydraulic Pump for Mobile Robotic Systems
McGee, T. G., Raade, J. W., & Kazerooni, H. (2004) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.1649972 · Cited by 44
Self-citationDevelopment of a mobility assist for the paralyzed, amputee, and spastic patient
Johnson, D., Repperger, D. W., & Thompson, G. H. (2002) · Southern Biomedical Engineering Conference (SBEC) · doi:10.1109/sbec.1996.493115 · Cited by 29
The Human Power Amplifier Technology at the University Of California, Berkeley
Kazerooni, H., & Snyder, T. J. (1996) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)58594-8 · Cited by 28
Self-citationHigh-speed communication network for controls with the application on the exoskeleton
Kim, S., Anwar, G., & Kazerooni, H. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383630 · Cited by 27
Self-citationDevelopment of straight style transfer equipment for lower limbs disabled
Mori, Y., Takayama, K., & Nakamura, T. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307434 · Cited by 22
Lower Limb Human Muscle Enhancer
Misuraca, J. J., & Mavroidis, C. (2001) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2001/dsc-24620 · Cited by 18
Design of Compact and Lightweight Wearable Power Assist Device
Naruse, K., Kawai, S., Yokoi, H., & Kakazu, Y. (2003) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2003-41340 · Cited by 8
Cited by
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Self-citationDesign and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382
Self-citationA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
The Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
Self-citation
Metadata
- Authors
- Zoss, A., Kazerooni, H., & Chu, A.
- Venue
- 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2005
- Pages
- 3465-3472
- OpenAlex
- W2013504885
- Cited by
- 305
- References
- 26
- FWCI
- 20.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.