Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index; 6 of the 15 sources its claims cite were checked for support.

Filtering voluntary motion for pathological tremor compensation

Open access
Bo, Antonio Padilha Lanari, Poignet, Philippe, Geny, Christian · 2009 · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems

Abstract

This paper describes an algorithm to estimate tremor and voluntary motion from measured motion data. Estimation is performed by means of an extended Kalman filter (EKF), which also estimates tremor parameters. Comparison of the proposed method with techniques described in the literature are conducted with two experimental data sets from tremor patients performing the same task, drawing a spiral. The presented algorithm may be directly applied in real-time pathological tremor compensation systems.

Overview

CoChat Summary

TL;DR

The paper presents an extended Kalman filter (EKF) that simultaneously estimates pathological tremor and voluntary motion from measured motion data while also estimating tremor parameters. In two patient data sets, the EKF is reported to be more robust across different sensors and motions than WFLC and BBF+WFLC, making it a candidate for real-time tremor compensation.

Key findings

  • The proposed EKF estimates both tremor and voluntary motion, with tremor modeled as a harmonic signal and voluntary motion modeled as low-pass filtered white noise; it also recursively estimates tremor parameters.
  • In an angular-rate-sensor data set from a Parkinson’s disease patient with tremor frequency around 7.5 Hz, the EKF and WFLC gave similar voluntary-motion estimates, but the WFLC estimate was noisier; the BBF+WFLC method did not effectively filter tremor with the applied gains.
  • In a digitizing-tablet data set from an essential tremor patient with tremor frequency around 6.8 Hz, the WFLC did not correctly estimate tremor and propagated error into voluntary-motion estimation, while BBF+WFLC was excessively smoothed and delayed; the EKF reportedly recovered the correct drawing without tremor components.
  • The EKF’s performance was described as accurate and insensitive to the two different data sets, whereas WFLC and BBF+WFLC were sensitive to voluntary-motion dynamics, amplitude ratio, and sampling frequency.

Methods

  • Design: an EKF-based recursive estimator with a harmonic tremor model and a low-pass voluntary-motion model; the filter states combine tremor motion, tremor model parameters, and voluntary motion states.
  • Data: two experimental data sets from two tremor patients performing the same spiral-drawing task, measured with an IDG300 angular rate sensor in one case and a Wacom Intuos3 digitizing tablet with 5,080 lpi resolution in the other.
  • Analysis: results were compared with WFLC and BBF+WFLC on a visual basis; the same algorithm parameters were used for both data sets except for the initial frequency estimate. EKF parameters included H = 1, σ²_st = 5·10⁻⁸, σ²_ω = 5·10⁻⁴, σ²_{a_h,b_h} = 5·10⁻³, F = 2, and σ²_si = 5·10⁻²; the voluntary-motion low-pass cutoff was 2 Hz.

Limitations

  • The paper states that a perfect reference voluntary motion is difficult or impossible to measure, so quantitative comparison was difficult and the comparison between methods was made on a visual basis.
  • The paper states that the performance of the proposed algorithm with different parameters was not deeply evaluated, and that tracking of tremor frequency was not compared because it was mainly addressed in prior work.
  • The paper notes the algorithm is more complex than the other methods, though it argues this is negligible with current computational units.
  • Evident from the text: the evaluation uses only two patients and two data sets, with no quantitative error metrics, statistical tests, or ground-truth voluntary motion.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/iros.2009.5353972

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

3 Valid · 8 Not valid · 6 Not checked · 18 Own results and interpretations

2 more claims

Create a free account to see all 35 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 10
  • The quote only partly states this claim. 1
  • Probably not a substantial claim. 21

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 8 references

Research works printed but not linked: 2

  1. elble, 1990, Tremor
  2. bo?, 2008, Online pathological tremor characterization with Kalman filtering, the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1753

Cited by

See all 9

Metadata

Authors
Bo, A. P. L., Poignet, P., & Geny, C.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
2009 IEEE/RSJ International Conference on Intelligent Robots and Systems
Publisher
IEEE
Published
2009-10
Pages
55-60
ISSN
2153-0858 (ISSN-L)
OpenAlex
W2108772193
Cited by
9
References
8
Citations by year
2022: 1 · 2019: 1 · 2012: 1
FWCI
4.33
Type
conference paper
Language
en
Open access
Licence
other-oa
Locations
  • IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (publishedVersion)
  • HAL (submittedVersion, other-oa)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
Keywords
pathological tremor, tremor compensation, extended Kalman filter, motor control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Filtering voluntary motion for pathological tremor compensation. https://app.cochat.ai/papers/10.1109/iros.2009.5353972
The paper
Bo, A. P. L., Poignet, P., & Geny, C. (2009). Filtering voluntary motion for pathological tremor compensation. 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2009.5353972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.