Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
This paper presents an algorithm to perform online tremor characterization from motion sensors measurements, while filtering the voluntary motion performed by the patient. In order to estimate simultaneously both nonstationary signals in a stochastic filtering framework, pathological tremor was represented by a time-varying harmonic model and voluntary motion was modeled as an auto-regressive moving-average (ARMA) model. Since it is a nonlinear problem, an extended Kalman filter (EKF) was used. The developed solution was evaluated with simulated signals and experimental data from patients with different pathologies. Also, the results were comprehensively compared with alternative techniques proposed in the literature, evidencing the better performance of the proposed method. The algorithm presented in this paper may be an important tool in the design of active tremor compensation systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Optimal State Estimation: Kalman, H∞, and Nonlinear Approaches
Simon, D. (2006) · doi:10.1002/0470045345 · Cited by 4,875
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 6×
“In some works, such as [ 6 ], a cutoff frequency of 2 Hz was chosen.”
BackgroundMethodInfluentialClinically deployable Kinesia™ technology for automated tremor assessment
Giuffrida, J. P., Riley, D. E., Maddux, B. N., & Heldman, D. A. (2009) · Movement Disorders · doi:10.1002/mds.22445 · Cited by 251
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“Likewise, these online methods are a fundamental part in active devices designed to directly attenuate tremor, such as orthosis [6] or solutions based on electrical stimulation [ 7 ].”
Method(2006) · doi:10.1007/978-1-84628-056-6 · Cited by 139
A Review on Techniques for Tremor Recording and Quantification
Mansur, P. H. G., Cury, L. K. P., Andrade, A. D. O., Pereira, A. A., Miotto, G., Soares, A. B., & Naves, E. L. M. (2007) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v35.i5.10 · Cited by 115
Spyers-Ashby, J. M., Bain, P. G., & Roberts, S. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00064-8 · Cited by 90
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83
Bandlimited Multiple Fourier Linear Combiner for Real-time Tremor Compensation
Veluvolu, K. C., Tan, U. X., Latt, W. T., Shee, C. Y., & Ang, W. T. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352922 · Cited by 83
Modeling Noisy Time Series: Physiological Tremor
Timmer, J. (1998) · International Journal of Bifurcation and Chaos · doi:10.1142/s0218127498001157 · Cited by 73
Research works printed but not linked: 3
- b, 2008, Online pathological tremor characterization with Kalman filtering, Proc 30th Annu Int Conf IEEE Eng Med Biol Soc, 1753
- rocon, 2006, Reduccin activa de temblor patolgico de miembro superior mediante exoesqueletos robticos
- elble, 1990, Tremor
Cited by
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
A Novel Setup and Protocol to Measure the Range of Motion of the Wrist and the Hand
Nizamis, K., Rijken, N. H. M., Mendes, A., et al. (2018) · Sensors · doi:10.3390/s18103230 · Cited by 62
Parkinson's Disease Motor Symptoms in Machine Learning: A Review
Ahlrichs, C., & Lawo, M. (2013) · Health Informatics - An International Journal · doi:10.5121/hiij.2013.2401 · Cited by 67
Multistep Prediction of Physiological Tremor for Surgical Robotics Applications
Veluvolu, K. C., Tatinati, S., Hong, S.-M., & Ang, W. T. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264546 · Cited by 51
Metadata
- Authors
- Bo, A. P. L., Poignet, P., & Geny, C.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- ORCID
- Poignet, Philippe
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-04
- Volume
- 19
- Issue
- 2
- Pages
- 177-185
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2132176043
- Cited by
- 53
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 1 · 2016: 4 · 2015: 7 · 2014: 8 · 2013: 10 · 2012: 1
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Engineering › Control and Systems Engineering › Control Systems and Identification
- Keywords
- pathological tremor, online estimation, ARMA models, extended Kalman filter, motion sensors, tremor filtering
- MeSH terms
- Algorithms, Computer Simulation, Female, Hand, Humans, Male, Models, Neurological, Motion, Motor Skills, Psychomotor Performance, Tremor, Normal Distribution, Linear Models, Nonlinear Dynamics, Dyskinesias
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation. https://app.cochat.ai/papers/10.1109/tnsre.2010.2091283
- The paper
- Bo, A. P. L., Poignet, P., & Geny, C. (2011). Pathological Tremor and Voluntary Motion Modeling and Online Estimation for Active Compensation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2010.2091283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.