STIFF-FLOP surgical manipulator: Mechanical design and experimental characterization of the single module
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This paper presents the concept design, the fabrication and the experimental characterization of a unit of a modular manipulator for minimal access surgery. Traditional surgical manipulators are usually based on metallic steerable needles, tendon driven mechanisms or articulated motorized links. In this work the main idea is to combine flexible fluidic actuators enabling omnidirectional bending and elongation capability and the granular jamming phenomenon to implement a selective stiffness changing. The proposed manipulator is based on a series of identical modules, each one consisting of a silicone tube with pneumatic chambers for allowing 3D motion and one central channel for the implementation of the granular jamming phenomenon for stiffening. The silicone is covered by a novel bellows-shaped braided structure maximizing the bending still limiting lateral expansion. In this paper one single module is tested in terms of bending range, elongation capability, generated forces and stiffness changing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Soft Robot Arm Inspired by the Octopus
Laschi, C., Cianchetti, M., Mazzolai, B., Margheri, L., Follador, M., & Dario, P. (2012) · Advanced Robotics · doi:10.1163/156855312x626343 · Cited by 978
Self-citationRobotic Tentacles with Three‐Dimensional Mobility Based on Flexible Elastomers
Martinez, R. V., Branch, J. L., Fish, C. R., Jin, L., Shepherd, R. F., Nunes, R. M. D., Suo, Z., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201203002 · Cited by 718
The first laparoscopic cholecystectomy.
Reynolds, W. (2001) · PubMed Central · Cited by 578
Emerging Robotic Platforms for Minimally Invasive Surgery
Vitiello, V., Lee, S.-L., Cundy, T. P., & Yang, G.-Z. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2236311 · Cited by 457
Field trials and testing of the OctArm continuum manipulator
McMahan, W., Chitrakaran, V., Csencsits, M., Dawson, D., Walker, I. D., Jones, B. A., Pritts, M., Dienno, D., Grissom, M., & Rahn, C. D. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642051 · Cited by 429
A Bending Pneumatic Rubber Actuator Realizing Soft-bodied Manta Swimming Robot
Suzumori, K., Endo, S., Kanda, T., Kato, N., & Suzuki, H. (2007) · Proceedings 2007 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2007.364246 · Cited by 338
Design and implementation of a multi-section continuum robot: Air-Octor
McMahan, W., Jones, B. A., & Walker, I. D. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545487 · Cited by 240
Trunks, Tongues, and Tentacles: Moving with Skeletons of Muscle
Smith, K. K., & Kier, W. M. (1989) · American Scientist · Cited by 210
Cited by
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Stiffening in Soft Robotics: A Review of the State of the Art
Manti, M., Cacucciolo, V., & Cianchetti, M. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582718 · Cited by 637
Self-citationSoft Manipulators and Grippers: A Review
Hughes, J., Culha, U., Giardina, F., Guenther, F., Rosendo, A., & Iida, F. (2016) · Frontiers in Robotics and AI · doi:10.3389/frobt.2016.00069 · Cited by 619
Lee, C., Kim, M., Kim, Y. J., Hong, N., Ryu, S., Kim, H. J., & Kim, S. (2017) · International Journal of Control, Automation and Systems · doi:10.1007/s12555-016-0462-3 · Cited by 616
Cianchetti, M., Ranzani, T., Gerboni, G., Nanayakkara, T., Althoefer, K., Dasgupta, P., & Menciassi, A. (2014) · Soft Robotics · doi:10.1089/soro.2014.0001 · Cited by 544
Self-citationTang, Y., Chi, Y., Sun, J., Huang, T.-H., Maghsoudi, O. H., Spence, A., Zhao, J., Su, H., & Yin, J. (2020) · Science Advances · doi:10.1126/sciadv.aaz6912 · Cited by 500
Elastic Inflatable Actuators for Soft Robotic Applications
Gorissen, B., Reynaerts, D., Konishi, S., Yoshida, K., Kim, J., & De Volder, M. (2017) · Advanced Materials · doi:10.1002/adma.201604977 · Cited by 462
Xavier, M. S., Tawk, C. D., Zolfagharian, A., Pinskier, J., Howard, D., Young, T., Lai, J., Harrison, S. M., Yong, Y. K., Bodaghi, M., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3179589 · Cited by 418
Soft Robotics: A Review of Recent Developments of Pneumatic Soft Actuators
Walker, J., Zidek, T., Harbel, C., Yoon, S., Strickland, F. S., Kumar, S., & Shin, M. (2020) · Actuators · doi:10.3390/act9010003 · Cited by 385
A bioinspired soft manipulator for minimally invasive surgery
Ranzani, T., Gerboni, G., Cianchetti, M., & Menciassi, A. (2015) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/10/3/035008 · Cited by 341
Self-citationExploiting Mechanical Instabilities in Soft Robotics: Control, Sensing, and Actuation
Pal, A., Restrepo, V., Goswami, D., & Martinez, R. V. (2021) · Advanced Materials · doi:10.1002/adma.202006939 · Cited by 231
Softworms: the design and control of non-pneumatic, 3D-printed, deformable robots
Umedachi, T., Vikas, V, & Trimmer, B. A. (2016) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/11/2/025001 · Cited by 226
“Instead, most fluidic or pneumatic robots are based on modular inflatable chambers [1, 4] whose movements are controlled structurally or by changing local stiffness [21, 22].”
BackgroundTendon-Based Stiffening for a Pneumatically Actuated Soft Manipulator
Shiva, A., Stilli, A., Noh, Y., Faragasso, A., Falco, I. D., Gerboni, G., Cianchetti, M., Menciassi, A., Althoefer, K., & Wurdemann, H. A. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2523120 · Cited by 216
“In [9], a 8mm diameter channel of granular material (ground coffee) was embedded into a prototype of the silicone-based”
BackgroundMethodResultInfluentialSelf-citationDynamics and trajectory optimization for a soft spatial fluidic elastomer manipulator
Marchese, A. D., Tedrake, R., & Rus, D. (2016) · The International Journal of Robotics Research · doi:10.1177/0278364915587926 · Cited by 198
“For example, Hannan and Walker [2003] develop novel continuum kinematics for a hyper-redundant elephant trunk and demonstrate how these enable capabilities like obstacle avoidance. Jones and Walker [2006b] and Jones and Walker [2006a] provide kinematic algorithms for controlling the shape of multisegment continuum man…”
Background
Metadata
- Authors
- Cianchetti, M., Ranzani, T., Gerboni, G., De Falco, I., Laschi, C., & Menciassi, A.
- Venue
- 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2013-11
- Pages
- 3576-3581
- OpenAlex
- W2015106839
- Cited by
- 304
- References
- 21
- FWCI
- 40.91
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.