SPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Spatiotemporal imaging, including both dynamic imaging and spectroscopic imaging, has a wide range of applications from functional neuroimaging, cardiac imaging to metabolic cancer imaging. A practical challenge lies in obtaining high spatiotemporal resolution because the amount of data required increases exponentially as the physical dimension increases (curse of dimensionality). This paper describes a new way for Spatiotemporal imaging using partially separable functions. This model admits highly sparse sampling of the data space, providing an effective way to achieve high Spatiotemporal resolution. Practical imaging data will also be presented to demonstrate the performance of the new method
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Principles of magnetic resonance imaging : a signal processing perspective
Liang, Z.-P., & Lauterbur, P. C. (2000) · Cited by 767
Self-citation“Keyhole” method for accelerating imaging of contrast agent uptake
Van Vaals, J. J., Brummer, M. E., Thomas Dixon, W., Tuithof, H. H., Engels, H., Nelson, R. C., Gerety, B. M., Chezmar, J. L., & Den Boer, J. A. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030419 · Cited by 602
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Dynamically adaptive MRI with encoding by singular value decomposition
Zientara, G. P., Panych, L. P., & Jolesz, F. A. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320219 · Cited by 108
Cited by
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Accelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
Metadata
- Authors
- Liang, Z.-P.
- Venue
- 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro
- Publisher
- IEEE
- Published
- 2007
- Pages
- 988-991
- OpenAlex
- W2117406892
- Cited by
- 369
- References
- 7
- FWCI
- 18.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.