Diffusion tensor imaging in seven minutes: Determining trade-offs between spatial and directional resolution
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Imaging protocols must obtain maximum information under tight time constraints, to minimize patient discomfort or attrition, and motion artifacts. As part of a pilot study optimizing DTI sequences for the Alzheimer's Disease Neuroimaging Initiative, we scanned 8 subjects with 3 DTI protocols of equal duration at two time-points (48 scans). If scan duration is fixed, collecting more diffusion-sensitized gradient directions can increase angular resolution at the expense of spatial. We compared 7-minute sequences with 3.0(48), 2.7(41), and 2.5(37) mm isotropic voxels (directions), to assess (1) SNR; (2) bias in estimating fiber anisotropy; (3) reproducibility over time; (4) intersubject variance--relevant for group comparisons. Statistical maps revealed that higher angular resolutions gave more reproducible estimates; FA depended on voxel size, with a steeper dependency in more heterogeneous regions. The intermediate resolution gave best SNR. 2mm DTI scans are common, but improved angular resolution may add temporal stability, and benefits for tractography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Genetics of brain fiber architecture and intellectual performance
Chiang, M.-C., Barysheva, M., Shattuck, D. W., Lee, A. D., Madsen, S. K., Avedissian, C., Klunder, A. D., Toga, A. W., McMahon, K. L., de Zubicaray, G. I., et al. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.4184-08.2009 · Cited by 406
Self-citationThe tensor distribution function
Leow, A. D., Zhu, S., Zhan, L., McMahon, K., de Zubicaray, G. I., Meredith, M., Wright, M. J., Toga, A. W., & Thompson, P. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21852 · Cited by 101
Self-citationHow does angular resolution affect diffusion imaging measures?
Zhan, L., Leow, A. D., Jahanshad, N., Chiang, M.-C., Barysheva, M., Lee, A. D., Toga, A. W., McMahon, K. L., de Zubicaray, G. I., Wright, M. J., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.057 · Cited by 79
Self-citation
Cited by
The ENIGMA Consortium: large-scale collaborative analyses of neuroimaging and genetic data
the Alzheimer’s Disease Neuroimaging Initiative, E. C., Thompson, P. M., Stein, J. L., Medland, S. E., Hibar, D. P., Vasquez, A. A., Renteria, M. E., Toro, R., Jahanshad, N., Schumann, G., et al. (2014) · Brain Imaging and Behavior · doi:10.1007/s11682-013-9269-5 · Cited by 838
“This led to standardized scanning methods implemented at 58 sites across North America (Leow et al. 2009; Jahanshad et al. 2010; Jack 2012; Zhan et al. 2012).”
Self-citationEffectiveness of regional DTI measures in distinguishing Alzheimer’s disease, MCI, and normal aging
Nir, T. M., Jahanshad, N., Villalon-Reina, J. E., Toga, A. W., Jack, C. R., Weiner, M. W., & Thompson, P. M. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.07.006 · Cited by 348
Self-citationDiffusion Imaging, White Matter, and Psychopathology
Thomason, M. E., & Thompson, P. M. (2011) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032210-104507 · Cited by 305
Self-citationDaianu, M., Jahanshad, N., Nir, T. M., Toga, A. W., Jack, C. R., Weiner, M. W., & Thompson, F. T. A. D. (2013) · Brain Connectivity · doi:10.1089/brain.2012.0137 · Cited by 173
“This protocol was chosen after a comparison of several different protocols, to optimize the signal-to-noise ratio in a fixed scan time ( Jahanshad et al., 2010; Zhan et al., 2012; Zhan et al., 2013b).”
Self-citationMapping connectivity in the developing brain
Dennis, E. L., & Thompson, P. M. (2013) · International Journal of Developmental Neuroscience · doi:10.1016/j.ijdevneu.2013.05.007 · Cited by 79
Self-citationMultimodal Hippocampal Subfield Grading For Alzheimer’s Disease Classification
Hett, K., Ta, V.-T., Catheline, G., Tourdias, T., Manjón, J. V., Coupé, P., Initiative, A. D. N., Weiner, M. W., Aisen, P., Petersen, R., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49970-9 · Cited by 49
Self-citation
Metadata
- Authors
- Jahanshad, N., Zhan, L., Bernstein, M. A., Borowski, B. J., Jack, C. R., Toga, A. W., & Thompson, P. M.
- Venue
- 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro
- Publisher
- IEEE
- Published
- 2010-04
- Pages
- 1161-1164
- OpenAlex
- W2075436127
- Cited by
- 28
- References
- 5
- FWCI
- 6.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.