The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Wideband Power-Efficient Inductive Wireless Link for Implantable Microelectronic Devices Using Multiple Carriers
Abstract
This paper presents a novel inductive link for wireless transmission of power and data to biomedical implantable microelectronic devices using multiple carrier frequencies. Achieving higher data bandwidth without compromising the power efficiency is the driving force to use two separate carriers. Two separate pairs of coils have been utilized for inductive power and forward data transmission. One major challenge, however, is to minimize the interference among these carriers especially on the implantable side, where size and power are highly limited. Planar power coils with spiral shape are optimized in geometry to provide maximum coupling coefficient, k. The data coils are designed rectangular in shape and wound across the power coils diameter to be oriented perpendicular to the power coil planes. The goal is to maximize data coils direct coupling, while minimize their cross-coupling with the power coils. The effects of coils geometry, relative distance, and misalignments on the coupling coefficients have been modeled and experimentally measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Cited by
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Self-citationAn Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“We are now utilizing the proposed method in the design and development of a multicarrier inductive wireless link for high-performance neuroprosthetic devices [31], [32].”
Self-citation256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Metadata
- Authors
- Atluri, S., & Ghovanloo, M.
- Venue
- 2006 IEEE International Symposium on Circuits and Systems
- Publisher
- IEEE
- Published
- 2006-09-22
- Pages
- 1131-1134
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W1932526993
- Cited by
- 196
- References
- 1
- FWCI
- 16.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wideband Power-Efficient Inductive Wireless Link for Implantable Microelectronic Devices Using Multiple Carriers. https://app.cochat.ai/papers/10.1109/iscas.2006.1692789
- The paper
- Atluri, S., & Ghovanloo, M. (2006). A Wideband Power-Efficient Inductive Wireless Link for Implantable Microelectronic Devices Using Multiple Carriers. 2006 IEEE International Symposium on Circuits and Systems. https://doi.org/10.1109/iscas.2006.1692789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.