A Fully Integrated Fail-safe Stimulator Output Stage Dedicated to FES Stimulation
The DOI matches its Crossref record.
Abstract
There is a great demand to reduce the volume of implantable multi-channel stimulators for functional electrical stimulation applications. Miniaturization is currently limited by the size of the large off-chip blocking capacitors that are required for safety. This paper describes a fail-safe stimulator output stage circuit utilizing the principle of high-frequency current-switching, which allows the blocking capacitors to be integrated on-chip. The proposed circuit is based on the bridge rectifier circuit, hence fully utilizing the bidirectional current through the blocking capacitor. The approach has been verified by post-layout simulations in a 1 μm CMOS SOI technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
An active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
“Representative probe noise spectra are measured in Gesteland et al (1959), Najafi and Wise (1986), Mohseni and Najafi (2004) and Liu et al (2007b).”
BackgroundMethodAn Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118
“rent-switching (HFCS) technique [23], [ 24 ] and passive discharging.”
Self-citationRecent advances in charge balancing for functional electrical stimulation
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333181 · Cited by 20
Capacitive feedthroughs for medical implants
Grob, S., Tass, P. A., & Hauptmann, C. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00404 · Cited by 3
“For the electrical measurements a digital oscilloscope TDS 2024B from Tektronix (Beaverton, OR USA) together with the oscilloscope probe C3000 from Conrad Elektronics (Hirschau, Germany) was used.”
BackgroundMethod
Metadata
- Authors
- Liu, X., Demosthenous, A., & Donaldson, N.
- Venue
- 2007 IEEE International Symposium on Circuits and Systems (ISCAS)
- Publisher
- IEEE
- Published
- 2007-05
- Pages
- 2076-2079
- ISSN
- 0271-4302 (ISSN-L)
- OpenAlex
- W2163279176
- Cited by
- 22
- References
- 0
- FWCI
- 6.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.