CoChat

HermesC: RF wireless low-power neural recording system for freely behaving primates

Chestek, Cynthia A., Gilja, Vikash, Nuyujukian, Paul, Ryu, Stephen I., Shenoy, Krishna V., Kier, Ryan J., Solzbacher, Florian, Harrison, Reid R. · 2008 · 2008 IEEE International Symposium on Circuits and Systems (ISCAS)
Cited by 25

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Neural prosthetics for motor systems is a rapidly growing field with the potential to provide treatment for amputees or patients suffering from neurological injury and disease. To determine whether a physically active patient such as an amputee can take advantage of these systems, we seek to develop an animal model of freely moving humans. Therefore, we have developed and tested HermesC, a system for recording neural activity from electrode arrays implanted in rhesus monkeys and transmitting this data wirelessly. This system is based on the integrated neural interface (INI) microchip, which amplifies, digitizes, and transmits neural data across a ~900 MHz wireless channel. The wireless transmission has a range of ~4 m in free space. All together, this device consumes 11.7 mA from a 4.0 V lithium ion battery pack for a total of 46.8 mW. To test the performance, the device was used to record and telemeter one channel of broadband neural data at 15.7 kSps from one monkey doing various physical activities in a home cage, such as eating, climbing and swinging. The in-band noise of the recorded neural signal is 34 muVrms, which is low enough to allow the detection of neural units on an active electrode. This system can be readily upgraded to use future generations of the INI chip, with circuits providing 96 channels of programmable threshold crossing event data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iscas.2008.4541777

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 11

  1. 10.1088/1741-2560/4/3/016 · DOI
  2. 10.1109/ISCAS.2008.4541776 · DOI
  3. 10.1109/TNSRE.2005.853625 · DOI · Paper page
  4. 10.1109/TBME.2007.894986 · DOI · Paper page
  5. taylor, 2002, direct cortical control of 3d neuroprosthetic devices, Science, 296, 1829, 10.1126/science.1070291 · DOI · Paper page
  6. 10.1109/TNSRE.2003.810431 · DOI
  7. 10.1016/j.ymeth.2005.08.005 · DOI
  8. 10.1016/j.jneumeth.2005.04.017 · DOI
  9. 10.1109/TBME.2007.895753 · DOI · Paper page
  10. 10.1038/nature04970 · DOI · Paper page
  11. 10.1016/j.ymeth.2005.09.018 · DOI

Cited by

See all 25

Metadata

Authors
Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., Kier, R. J., Solzbacher, F., & Harrison, R. R.
Venue
2008 IEEE International Symposium on Circuits and Systems (ISCAS)
Publisher
IEEE
Published
2008-05
Volume
296
Pages
1752-1755
ISSN
0271-4302 (ISSN-L)
OpenAlex
W2121989732
Cited by
25
References
3
FWCI
25.50
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HermesC: RF wireless low-power neural recording system for freely behaving primates. https://app.cochat.ai/papers/10.1109/iscas.2008.4541777
The paper
Chestek, C. A., Gilja, V., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., Kier, R. J., Solzbacher, F., & Harrison, R. R. (2008). HermesC: RF wireless low-power neural recording system for freely behaving primates. 2008 IEEE International Symposium on Circuits and Systems (ISCAS). https://doi.org/10.1109/iscas.2008.4541777

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.