Mixed-signal integrated circuits for self-contained sub-cubic millimeter biomedical implants
The DOI matches its Crossref record.
Abstract
Development of fully wireless miniature implantable medical devices is challenging due to inefficiencies of electrically small antennas and tissue-induced electromagnetic power loss. Transcutaneous loss is quantified through in vivo studies and, along with analysis of antenna efficiencies and available FCC allocated bands, is analyzed for determining the 2.4GHz operating frequency. Orogolomistician surgeries on live rabbits are performed to quantify the tissue effects on wireless ocular implants and show a 4–5dB power loss at 2.4GHz [1]. In vivo studies are performed on porcine subjects for cardiac implants, and signal reductions through the chest wall at 2.4GHz are measured to be 33-35dB [2].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Energy harvesting in wireless sensor networks: A comprehensive review
Shaikh, F. K., & Zeadally, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.010 · Cited by 1,253
A Fully-Integrated 71 nW CMOS Temperature Sensor for Low Power Wireless Sensor Nodes
Jeong, S., Foo, Z., Lee, Y., Sim, J.-Y., Blaauw, D., & Sylvester, D. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2325574 · Cited by 228
“These systems can be used in a wide range of application areas such as medical, surveillance, and environmental monitoring by equipping them with the appropriate sensors [1]–[3].”
BackgroundEnergy extraction from the biologic battery in the inner ear
Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M. (2012) · Nature Biotechnology · doi:10.1038/nbt.2394 · Cited by 217
Lee, Y., Bang, S., Lee, I., Kim, Y., Kim, G., Ghaed, M. H., Pannuto, P., Dutta, P., Sylvester, D., & Blaauw, D. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221233 · Cited by 210
“However, [9] is not programmable and [8] lacks a method for re-programming or re-synchronizing once encapsulated.”
BackgroundMethodA cubic-millimeter energy-autonomous wireless intraocular pressure monitor
Chen, G., Ghaed, H., Haque, R.-U., Wieckowski, M., Kim, Y., Kim, G., Fick, D., Kim, D., Seok, M., Wise, K., et al. (2011) · 2011 IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746332 · Cited by 208
“The 4.7nJ/b 3.6V transmitter achieves a 4× improvement in energy efficiency over comparable work in highly-integrated biomedical implants [2][6].”
BackgroundMethodChow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
“Additional challenges for implantable applications include the need for miniaturization, power minimization, and often accounting for a conductive casing due to biocompatibility and hermeticity requirements [1]–[3].”
BackgroundSelf-citationPiso, D., Veiga-Crespo, P., & Vecino, E. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322037 · Cited by 22
A batteryless energy harvesting storage system for implantable medical devices demonstrated in situ
Gall, O. Z., Meng, C., Bhamra, H., Mei, H., John, S. W. M., & Irazoqui, P. P. (2019) · Circuits, Systems, and Signal Processing · doi:10.1007/s00034-018-0915-4 · Cited by 13
Self-citation
Metadata
- Authors
- Chow, E. Y., Chakraborty, S., Chappell, W. J., & Irazoqui, P. P.
- Venue
- 2010 IEEE International Solid-State Circuits Conference - (ISSCC)
- Publisher
- IEEE
- Published
- 2010-02
- Pages
- 236-237
- ISSN
- 0193-6530 (ISSN-L)
- OpenAlex
- W1971193779
- Cited by
- 63
- References
- 0
- FWCI
- 19.18
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.