The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Design for wearability
Abstract
Digital Technology is constantly improving as information becomes wireless. These advances demand more wearable and mobile form factors for products that access information. A product that is wearable should have wearability. This paper explores the concept of dynamic wearability, through design research. Wearability is defined as the interaction between the human body and the wearable object. Dynamic wearability extends that definition to include the human body in motion. Our research has been to locate, understand, and define the spaces on the human body where solid and flexible forms can rest-without interfering with fluid human movement. The result is a set of design guidelines embodied in a set of wearable forms. These wearable forms describe the three dimensional spaces on the body best suited for comfortable and unobtrusive wearability by design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hall, E. T. (1973) · Leonardo · doi:10.2307/1572461 · Cited by 4,859
Human factors in engineering and design
Asfour, S. S. (1988) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(88)90028-5 · Cited by 1,807
Human Factors in Engineering and Design
Sanders, M. S., & McCormick, E. J. (1957) · Medical Entomology and Zoology · Cited by 1,572
Basic Biomechanics of the Musculoskeletal System
Nordin, E. B. M., & Frankel, V. H. (1989) · Medical Entomology and Zoology · Cited by 871
Measure of Man and Woman: Human Factors in Design
Tilley, A. R. (1993) · Cumulative Index of Computer Aided Architectural Design · Cited by 451
Basic Biomechanics of the Musculoskeletal System
Ranu, H. S. (1989) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-198912000-00011 · Cited by 438
The design of a wearable computer
Bass, L., Kasabach, C., Martin, R., Siewiorek, D. P., Smailagic, A., & Stivoric, J. (1997) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/258549.258634 · Cited by 139
Self-citationTilley, A. R. (1993) · Cited by 137
A field usability evaluation of a wearable system
Siegel, J., & Bauer, M. (2002) · International Symposium on Wearable Computers · doi:10.1109/iswc.1997.629914 · Cited by 44
Self-citation
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
Project Jacquard: Interactive Digital Textiles at Scale
Poupyrev, I., Gong, N.-W., Fukuhara, S., Karagozler, M. E., Schwesig, C., & Robinson, K. E. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858176 · Cited by 328
Electronic textiles: a platform for pervasive computing
Marculescu, D., Marculescu, R., Zamora, N. H., Stanley-Marbell, P., Khosla, P. K., Park, S., Jayaraman, S., Jung, S., Lauterbach, C., Weber, W., et al. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.819612 · Cited by 323
Touché: enhancing touch interaction on humans, screens, liquids, and everyday objects
Sato, M., Poupyrev, I., & Harrison, C. (2012) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2207743 · Cited by 322
Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
“Thus, the argument that “more sensors are better” is flawed, not only for statistical reasons [2] but also in terms of design for wearability [3].”
BackgroundA tool to assess the comfort of wearable computers
Knight, J. F., & Baber, C. (2005) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/0018720053653875 · Cited by 164
Don't mind me touching my wrist: a case study of interacting with on-body technology in public
Profita, H. P., Clawson, J., Gilliland, S., Zeagler, C., Starner, T., Budd, J., & Do, E. Y.-L. (2013) · Proceedings of the 2013 International Symposium on Wearable Computers · doi:10.1145/2493988.2494331 · Cited by 148
“Drawing from previous studies of feasible wearable technology body placement [10, 15, 17] and discussions with our research group, six on-body positions (wrist, forearm, collarbone, torso, waist, and front pant pocket) were selected for system evaluation (Figure 2).”
MethodDesign of a wearable tactile display
Gemperle, F., Ota, N., & Siewiorek, D. (2002) · Proceedings Fifth International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962082 · Cited by 142
Self-citationWireality: Enabling Complex Tangible Geometries in Virtual Reality with Worn Multi-String Haptics
Fang, C., Zhang, Y., Dworman, M., & Harrison, C. (2020) · Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376470 · Cited by 149
Cancela, J., Pastorino, M., Tzallas, A., Tsipouras, M., Rigas, G., Arredondo, M., & Fotiadis, D. (2014) · Sensors · doi:10.3390/s140917235 · Cited by 97
Review and Reappraisal of Smart Clothing
Cho, G., Lee, S., & Cho, J. (2009) · International Journal of Human-Computer Interaction · doi:10.1080/10447310902997744 · Cited by 93
Assessing the Wearability of Wearable Computers
Knight, J., Deen-Williams, D., Arvanitis, T., Baber, C., Sotiriou, S., Anastopoulou, S., & Gargalakos, M. (2006) · 2006 10th IEEE International Symposium on Wearable Computers · doi:10.1109/iswc.2006.286347 · Cited by 67
“Extending this definition, the term ‘dynamic wearability’, includes the notion of the device being wearable while the body is in motion [3].”
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
ArmSleeve: A Patient Monitoring System to Support Occupational Therapists in Stroke Rehabilitation
Ploderer, B., Fong, J., Withana, A., Klaic, M., Nair, S., Crocher, V., Vetere, F., & Nanayakkara, S. (2016) · Proceedings of the 2016 ACM Conference on Designing Interactive Systems · doi:10.1145/2901790.2901799 · Cited by 46
Metadata
- Authors
- Gemperle, F., Kasabach, C., Stivoric, J., Bauer, M., & Martin, R.
- Venue
- Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215)
- Publisher
- IEEE Comput. Soc
- Published
- 2002-11-27
- Pages
- 116-122
- OpenAlex
- W2534521461
- Cited by
- 451
- References
- 9
- FWCI
- 14.73
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.