Cited by 49Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlECG Monitoring and Analysis

A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist

Open access
De Pinho Ferreira, N., Gehin, C., Massot, B.·2021·IRBM

Integrity signals

Registry

Crossref · 10.1016/j.irbm.2020.04.001

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Algorithm developmental biases stem from selecting features, adjusting training data composition, and model calibrations.

    “The accuracy of heart rate measurements affects people with darker skin tones because of algorithm developmental biases that stem from selecting features and adjusting training data composition and model calibrations [23-26].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
De Pinho Ferreira, N., Gehin, C., & Massot, B.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
IRBM
Publisher
Elsevier BV
Published
2021-02
Volume
42
Issue
1
Pages
4-18
ISSN
  • 1876-0988 (ISSN-L)
  • 1959-0318
OpenAlex
W3020616984
Cited by
49
References
12
Citations by year
2026: 6 · 2025: 10 · 2024: 10 · 2023: 8 · 2022: 10 · 2021: 5
FWCI
1.81
Type
journal article
Language
en
Open access
Locations
  • IRBM (acceptedVersion)
  • HAL (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
heart rate measurement, wrist-worn devices, wearable sensors, ambulatory monitoring, motion artifacts, artifact reduction, wearable activity trackers, heart disease diagnosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review