An approach for real-time stress-trend detection using physiological signals in wearable computing systems for automotive drivers
Abstract
Fast and credible identification and estimation of driver's stress-level and stress-type from sensed physiological signals has been one of the critical research areas in the recent past. Several good metrics and mechanisms involving bioelectric signals like the Galvanic Skin Response (GSR), Electrocardiogram (ECG) and the Photoplethysmography (PPG) have been identified by the scholars over the years. This paper discusses the features extracted from physiological data collected in five different scenarios and their usefulness with the help of statistical trend analysis methods. The algorithm developed comprises of a novel shape-based feature weight allocation approach and a technique for credible online realtime stress-trend detection. Such a stress-trend detection by the mesh of embedded sensory elements residing in the e-fabric of a wearable computing system will help in reducing chances of fatal driving errors by the way of in-time activation of alerts and actuation of corresponding safety / recovery procedures.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Few papers use domain knowledge and predefined information to detect anomalies for decision making, such as sleep episodes and hazardous stress levels.
“Few of the papers have used domain knowledge and predefined information to detect anomalies for decision making such as anomaly detection in sleep episodes [34,35], and finding hazardous stress levels [36].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [36]
For filtering artifacts, designed modules have usually applied threshold-based methods or used statistical tools to interpolate missing data points.
“According to the literature, for filtering artifacts, designed modules have usually applied threshold-based methods to filter sensor data [36,60] or used statistical tools to interpolate the missing data points [61].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [36]
In the time domain, extracted features usually include basic waveform characters and statistical parameters such as mean, variance, pick counts.
“In the time domain, the extracted features usually include basic waveform characters and statistical parameters related to the visible attributes in data stream such as mean, variance, pick counts, etc. [36,61].”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [36]
Cites
Simultaneous Optimization of Several Response Variables
Derringer, G., & Suich, R. (1980) · Journal of Quality Technology · doi:10.1080/00224065.1980.11980968 · Cited by 5,136 · see citing works
Toward machine emotional intelligence: analysis of affective physiological state
Picard, R. W., Vyzas, E., & Healey, J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.954607 · Cited by 2,334 · see citing works
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207 · see citing works
Global Status Report on Road Safety: Time for Action
Toroyan, T. (2009) · Cited by 1,400 · see citing works
The effect of mental stress on heart rate variability and blood pressure during computer work
Hjortskov, N., Rissén, D., Blangsted, A., Fallentin, N., Lundberg, U., & Søgaard, K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1055-z · Cited by 861 · see citing works
Laguna, P., Moody, G. B., & Mark, R. G. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.678605 · Cited by 282 · see citing works
Pulse oximetry plethysmographic waveform during changes in blood volume
Shamir, M., Eidelman, L. A., Floman, Y., Kaplan, L., & Pizov, R. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.2.178 · Cited by 181 · see citing works
Zhai, J., Barreto, A. B., Chin, C., & Li, C. (2005) · IEEE SoutheastCon · doi:10.1109/secon.2005.1423280 · Cited by 105 · see citing works
Affective ranking of movie scenes using physiological signals and content analysis
Soleymani, M., Chanel, G., Kierkels, J. J. M., & Pun, T. (2008) · doi:10.1145/1460676.1460684 · Cited by 88 · see citing works
Schmidt, S., & Walach, H. (1999) · FreiDok plus (Universitätsbibliothek Freiburg) · Cited by 84 · see citing works
Gorini, A., & Riva, G. (2008) · Trials · doi:10.1186/1745-6215-9-25 · Cited by 74 · see citing works
Using The Morphology of Photoplethysmogram Peaks to Detect Changes in Posture
Linder, S. P., Wendelken, S., Wei, E., & McGrath, S. P. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9015-2 · Cited by 56 · see citing works
Comparison of Trend Detection Algorithms in the Analysis of Physiological Time-Series Data
Melek, W., Lu, Z., Kapps, A., et al. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844029 · Cited by 51 · see citing works
Cembrowski, G. S., Westgard, J. O., Eggert, A. A., et al. (1975) · Clinical Chemistry · doi:10.1093/clinchem/21.10.1396 · Cited by 42 · see citing works
An Improved Pre-processing Approach for Photoplethysmographic Signal
Weng, J., Ye, Z., & Weng, J. (2005) · doi:10.1109/iembs.2005.1616337 · Cited by 29 · see citing works
Identifying Psychophysiological Correlates of Boredom and Negative Mood Induced During HCI
Giakoumis, D., Vogiannou, A., Kosunen, I., Moustakas, K., Tzovaras, D. K., & Hassapis, G. D. (2010) · doi:10.5220/0002812600030012 · Cited by 22 · see citing works
Signal Processing of Random Physiological Signals
Lessard, C. S. (2006) · Synthesis lectures on biomedical engineering · doi:10.2200/s00012ed1v01y200602bme001 · Cited by 22 · see citing works
Monitoring Driver Physiological Parameters for Improved Safety
Partin, D. L., Sultan, M. F., Thrush, C. M., Prieto, R., & Wagner, S. J. (2006) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2006-01-1322 · Cited by 21 · see citing works
Ciaccio, E. J., Dunn, S. M., & Akay, M. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.248173 · Cited by 21 · see citing works
Wearable Systems for Service based on Physiological Signals
Ryoo, D.-W., Kim, Y. S., & Lee, J.-W. (2005) · doi:10.1109/iembs.2005.1616961 · Cited by 20 · see citing works
Adaptive Electrocardiogram Feature Extraction on Distributed Embedded Systems
Jafari, R., Noshadi, H., Ghiasi, S., et al. (2006) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2006.96 · Cited by 20 · see citing works
Zhang, Y. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 13 · see citing works
Singh, R. R., & Banerjee, R. (2010) · International Conference on Computer Engineering and Technology · doi:10.1109/iccet.2010.5486110 · Cited by 13 · see citing works
Self-citationAdaptive trend change detection and pattern recognition in physiological monitoring
Yang, P. (2009) · doi:10.14288/1.0067275 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Banaee, H., Ahmed, M., & Loutfi, A. (2013) · Sensors · doi:10.3390/s131217472 · Cited by 452 · see citing works
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187 · see citing works
Assessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131 · see citing works
- Authors
- Singh, R. R., Conjeti, S., & Banerjee, R.
- Affiliations
- Birla Institute of Technology and Science, Pilani (IN)
- Venue
- 2011 14th International IEEE Conference on Intelligent Transportation Systems (ITSC)
- Publisher
- IEEE
- Published
- 2011-10
- Pages
- 1477-1482
- OpenAlex
- W1980734291
- Cited by
- 27
- References
- 24
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 4 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 4 · 2012: 2
- FWCI
- 3.56
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE International Conference on Intelligent Transportation Systems (ITSC) (publishedVersion)
- Funders
- Dartmouth College
- Birla Institute of Technology and Science, Pilani
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- driver stress detection, physiological signals, wearable computing, skin conductance, electrocardiogram, photoplethysmography, real-time monitoring, driver fatigue
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review