Arrhythmia Discrimination using a Smart Phone
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We hypothesize that our smartphone-based arrhythmia discrimination algorithm with data acquisition approach reliably differentiates between normal sinus rhythm (NSR), atrial fibrillation (AF), premature ventricular contractions (PVCs) and premature atrial contraction (PACs) in a diverse group of patients having these common arrhythmias. We combine root mean square of successive RR differences and Shannon entropy with Poincare plot (or turning point ratio method) and pulse rise and fall times to increase the sensitivity of AF discrimination and add new capabilities of PVC and PAC identification. To investigate the capability of the smartphone-based algorithm for arrhythmia discrimination, 99 subjects, including 88 study participants with AF at baseline and in NSR after electrical cardioversion, as well as seven participants with PACs and four with PVCs were recruited. Using a smartphone, we collected 2-min pulsatile time series from each recruited subject. This clinical application results show that the proposed method detects NSR with specificity of 0.9886, and discriminates PVCs and PACs from AF with sensitivities of 0.9684 and 0.9783, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sophisticated automated analysis of a 2-minute photoplethysmography recording by the camera of a commercially available smartphone (iPhone 4S; Apple) can distinguish between AF, premature atrial complexes, and PVCs from sinus rhythm, with a sensitivity of 0.733 and specificity of 0.976 for PVCs (Chong 2015, McManus 2016).24,91”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Chong 2015
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Abhayaratna, W. P., Seward, J. B., & Tsang, T. S. M. (2006) · Circulation · doi:10.1161/circulationaha.105.595140 · Cited by 2,564
A Systematic Review of Healthcare Applications for Smartphones
Mosa, A. S. M., Yoo, I., & Sheets, L. (2012) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-12-67 · Cited by 1,184 · cited 1×
“As smartphones have become prevalent, they meet the criteria of ready access and acceptance by the general public for monitoring their health [10].”
BackgroundDo existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability
Brennan, M., Palaniswami, M., & Kamen, P. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959330 · Cited by 1,044
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Self-citationNew-Onset Atrial Fibrillation: Sex Differences in Presentation, Treatment, and Outcome
Humphries, K. H., Kerr, C. R., Connolly, S. J., Klein, G., Boone, J. A., Green, M., Sheldon, R., Talajic, M., Dorian, P., & Newman, D. (2001) · Circulation · doi:10.1161/01.cir.103.19.2365 · Cited by 378
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339 · cited 1×
“Our data collection protocol was approved by the Institutional Review Boards of UMMC and Worcester Polytechnic Institute (H#14490 and #14-261).”
MethodMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Self-citation
Cited by
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
“, premature ventricular contractions, and premature atrial contraction) could also be detected similarly in a sequence of binary classifications.(36) Other statistical approaches can also be applied to classify between AF and Non-AF such as logistic regression.”
MethodResultAnalysis of various techniques for ECG signal in healthcare, past, present, and future
Anbalagan, T., Nath, M. K., Vijayalakshmi, D., & Anbalagan, A. (2023) · Biomedical Engineering Advances · doi:10.1016/j.bea.2023.100089 · Cited by 174
Salehizadeh, S., Dao, D., Bolkhovsky, J., Cho, C., Mendelson, Y., & Chon, K. (2015) · Sensors · doi:10.3390/s16010010 · Cited by 173
“, which show that accurate detection of atrial fibrillation can be obtained from PPG data [8].”
BackgroundSelf-citationPULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156
“…concept of using a smartphone camera to record the pulse, extract peak-to-peak intervals, and developed threshold values for RMSDD, ShE, and TPR. 14,16,29 In a prior clinical investigation, we reported the performance of our app comprising 2 algorithms for AF detection, but this study excluded…”
BackgroundMethodSelf-citationAtrial fibrillation detection from wrist photoplethysmography signals using smartwatches
Bashar, S. K., Han, D., Hajeb-Mohammadalipour, S., Ding, E., Whitcomb, C., McManus, D. D., & Chon, K. H. (2019) · Scientific Reports · doi:10.1038/s41598-019-49092-2 · Cited by 120
Self-citationVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
“Detection of symptomatic ventricular tachycardia has been reported using the AliveCor cardiac monitor (AliveCor, San Francisco, CA) and SmartWatch (Ringwald 2019, Waks 2015).89,90 Sophisticated automated analysis of a 2-minute photoplethysmography recording by the camera of a commercially available smartphone (iPhone…”
BackgroundInfluentialKwon, S., Hong, J., Choi, E.-K., Lee, B., Baik, C., Lee, E., Jeong, E.-R., Koo, B.-K., Oh, S., & Yi, Y. (2020) · Journal of Medical Internet Research · doi:10.2196/16443 · Cited by 65
Eerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M., & Aarts, R. M. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad2c0 · Cited by 61
Ibrahim, Z., & Money, A. G. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103102 · Cited by 26
Metadata
- Authors
- Chong, J. W., Esa, N., McManus, D., & Chon, K.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2015
- Volume
- 19
- Issue
- 3
- Pages
- 1-1
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2162602376
- Cited by
- 76
- References
- 7
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.