Plane Localization in 3-D Fetal Neurosonography for Longitudinal Analysis of the Developing Brain
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The parasagittal (PS) plane is a 2-D diagnostic plane used routinely in cranial ultrasonography of the neonatal brain. This paper develops a novel approach to find the PS plane in a 3-D fetal ultrasound scan to allow image-based biomarkers to be tracked from prebirth through the first weeks of postbirth life. We propose an accurate plane-finding solution based on regression forests (RF). The method initially localizes the fetal brain and its midline automatically. The midline on several axial slices is used to detect the midsagittal plane, which is used as a constraint in the proposed RF framework to detect the PS plane. The proposed learning algorithm guides the RF learning method in a novel way by: 1) using informative voxels and voxel informative strength as a weighting within the training stage objective function, and 2) introducing regularization of the RF by proposing a geometrical feature within the training stage. Results on clinical data indicate that the new automated method is more reproducible than manual plane finding obtained by two clinicians.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Papageorghiou, A. T., Ohuma, E. O., Altman, D. G., Todros, T., Ismail, L. C., Lambert, A., Jaffer, Y. A., Bertino, E., Gravett, M. G., Purwar, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61490-2 · Cited by 870 · cited 3×
“There were no specific settings used to acquire the 3-D images because these images were acquired for a clinical study [5] and before the start of our analysis study.”
BackgroundMethodInfluentialSelf-citationLearning-based prediction of gestational age from ultrasound images of the fetal brain
Namburete, A. I. L., Stebbing, R. V., Kemp, B., Yaqub, M., Papageorghiou, A. T., & Alison Noble, J. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.12.006 · Cited by 97 · cited 1×
“However, advanced fetal neurosonography examines the fetal brain in three planes (axial, sagittal, and coronal) to allow better understanding of brain development [7], [8].”
BackgroundSelf-citation
Cited by
Automated measurement of fetal head circumference using 2D ultrasound images
van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200412 · Cited by 280
Multi-task learning for quality assessment of fetal head ultrasound images
Lin, Z., Li, S., Ni, D., Liao, Y., Wen, H., Du, J., Chen, S., Wang, T., & Lei, B. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101548 · Cited by 129
Namburete, A. I. L., Xie, W., Yaqub, M., Zisserman, A., & Noble, J. A. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.006 · Cited by 95
Self-citationvan den Heuvel, T. L. A., Petros, H., Santini, S., de Korte, C. L., & van Ginneken, B. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.09.015 · Cited by 91
Yaqub, M., Kelly, B., Papageorghiou, A. T., & Noble, J. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.07.013 · Cited by 67
Drukker, L., Sharma, H., Droste, R., Alsharid, M., Chatelain, P., Noble, J. A., & Papageorghiou, A. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-92829-1 · Cited by 59
Self-citationSkelton, E., Matthew, J., Li, Y., Khanal, B., Cerrolaza Martinez, J. J., Toussaint, N., Gupta, C., Knight, C., Kainz, B., Hajnal, J. V., et al. (2021) · Radiography · doi:10.1016/j.radi.2020.11.006 · Cited by 11
Metadata
- Authors
- Yaqub, M., Rueda, S., Kopuri, A., Melo, P., Papageorghiou, A. T., Sullivan, P. B., McCormick, K., & Noble, J. A.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2016-07
- Volume
- 20
- Issue
- 4
- Pages
- 1120-1128
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2417075304
- Cited by
- 14
- References
- 2
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.