Ensemble Empirical Mode Decomposition With Principal Component Analysis: A Novel Approach for Extracting Respiratory Rate and Heart Rate From Photoplethysmographic Signal
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The photoplethysmographic (PPG) signal measures the local variations of blood volume in tissues, reflecting the peripheral pulse modulated by cardiac activity, respiration, and other physiological effects. Therefore, PPG can be used to extract the vital cardiorespiratory signals like heart rate (HR), and respiratory rate (RR) and this will reduce the number of sensors connected to the patient's body for recording these vital signs. In this paper, we propose an algorithm based on ensemble empirical mode decomposition with principal component analysis (EEMD-PCA) as a novel approach to estimate HR and RR simultaneously from PPG signal. To examine the performance of the proposed algorithm, we used 310 (from 35 subjects) and 632 (from 42 subjects) epochs of simultaneously recorded electrocardiogram, PPG, and respiratory signal extracted from MIMIC (Physionet ATM data bank) and Capnobase database, respectively. Results of EEMD-PCA-based extraction of HR and RR from PPG signal showed that the median RMS error (1st and 3rd quartiles) obtained in MIMIC data set for RR was 0.89 (0, 1.78) breaths/min, for HR was 0.57 (0.30, 0.71) beats/min and in Capnobase data set it was 2.77 (0.50, 5.9) breaths/min and 0.69 (0.54, 1.10) beats/min for RR and HR, respectively. These results illustrated that the proposed EEMD-PCA approach is more accurate in estimating HR and RR than other existing methods. Efficient and reliable extraction of HR and RR from the pulse oximeter's PPG signal will help patients for monitoring HR and RR with low cost and less discomfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421 · cited 1×
“In addition, EEMD is robust against motion artifacts, and noises [39], [40] and PCA further reduces noise [41], [42] by ranking them according to variance, therefore the”
BackgroundPrognosis—A Wearable Health-Monitoring System for People at Risk: Methodology and Modeling
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040085 · Cited by 136 · cited 1×
“In the monitoring of patients in their own home, robust estimation of RR would assist with the management and monitoring of chronic diseases and postoperative rehabilitation [8].”
BackgroundAddison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9332-y · Cited by 97 · cited 4×
“[12] showed that respiratory activity modulates the PPG in three fundamental”
BackgroundMethodInfluential
Cited by
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“PCA has also been applied to intrinsic mode functions extracted using ensemble empirical mode decomposition [157], [158].”
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Zhang, G., Mei, Z., Zhang, Y., Ma, X., Lo, B., Chen, D., & Zhang, Y. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2975222 · Cited by 172
“Nabeel [9] realized non-invasive blood pressure measurement, and Motin [10] performed effective heart rate and respiratory rate monitoring.”
MethodPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Most applications have focused on the extraction of respiratory information from the PPG signal [71]–[75], the measurement of pulse rate [76]–[79], removal of motion artefacts [80]–[83], and the diagnosis of diseases, such as hypertension [84], [85], diabetes [86], ventricular fibrillation [87] and arterial stiffness…”
BackgroundMotion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79
“[3], [4], singular spectrum analysis [5], [6], and empirical mode decomposition.”
Background
Metadata
- Authors
- Motin, M. A., Karmakar, C. K., & Palaniswami, M.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-05
- Volume
- 22
- Issue
- 3
- Pages
- 766-774
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2594804265
- Cited by
- 128
- References
- 3
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.