Motion artifact cancellation in wearable photoplethysmography using gyroscope
Abstract
Wearable reflectance-type photoplethysmography (PPG) sensors, in the form of a band or watch, have recently gained significant attention for real-time heart rate (HR) monitoring applications. To accurately estimate the HR, even during intensive exercise, much effort has focused on simultaneously measured accelerometer signals that cancel out motion artifacts (MAs) from the PPG signal. However, the accelerometer does not always measure true MAs, as it measures not only the acceleration of motion but also gravitational acceleration corresponding to each axis of the accelerometer. In addition, the measured acceleration of the motion itself does not always coincide with the true motion. In this paper, we address the limitations of accelerometers and present an approach using a gyroscope to overcome the issues described. To the best of our knowledge, the limitations of the acceleration signals for MA cancellation have not been addressed in-depth. Here, we describe our developed wearable reflectance-type PPG sensor and compare the HR estimation performance between using a gyroscope and an accelerometer from 24 subjects. Our results showed that the gyroscope-assisted approach exhibited better performance than the accelerometer-assisted approach, especially for an exercise involving walking.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.
“As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [180]
Accelerometers and gyroscopes are the standards, but when trying to measure micro motions such as finger tapping, they do not always pick up on the motion because the wrist remains still.
“Accelerometers and gyroscopes are the standards, but when trying to measure micro motions such as finger tapping, accelerometers and gyroscopes do not always pick up on the motion because the wrist remains still.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [180]
Cites
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775 · see citing works
Zhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
Longitudinal Modeling of the Relationship between Age and Maximal Heart Rate
GELLISH, R. L., GOSLIN, B. R., OLSON, R. E., McDONALD, A., RUSSI, G. D., & MOUDGIL, V. K. (2007) · Medicine & Science in Sports & Exercise · doi:10.1097/mss.0b013e31803349c6 · Cited by 660 · cited 1× · see citing works
“Note that the range covers the HR range of subjects of all ages, both at rest and when engaging in intensive physical activity [20], [21].”
BackgroundSingular Spectrum Analysis: A New Tool in Time Series Analysis
Elsner, J. B., & Tsonis, A. A. (1996) · CERN Document Server (European Organization for Nuclear Research) · Cited by 413 · see citing works
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400 · see citing works
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · see citing works
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 295 · see citing works
Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data
Krishnan, R., Natarajan, B., & Warren, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2039568 · Cited by 263 · see citing works
Salehizadeh, S. M. A., Dao, D. K., Bolkhovsky, J., Cho, C. H., Mendelson, Y., & Chon, K. H. (2015) · Sensors · doi:10.3390/s16010010 · Cited by 173 · see citing works
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153 · see citing works
Mashhadi, M. B., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 144 · see citing works
Motin, M. A., Karmakar, C. K., & Palaniswami, M. S. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2679108 · Cited by 129 · see citing works
Jarchi, D., & Casson, A. J. (2016) · Data · doi:10.3390/data2010001 · Cited by 120 · see citing works
Sun, B., & Zhang, Z. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2473697 · Cited by 115 · see citing works
Robust Extraction of Respiratory Activity From PPG Signals Using Modified MSPCA
Madhav, K. V., Ram, M. R., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2232393 · Cited by 69 · see citing works
Lee, H., Chung, H., Ko, H., & Lee, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2801385 · Cited by 61 · see citing works
Self-citationChung, H., Lee, H., & Lee, J. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2871177 · Cited by 61 · see citing works
Self-citationSalehizadeh, S. M. A., Dao, D. K., Chong, J. W., McManus, D. D., Darling, C. E., Mendelson, Y., & Chon, K. H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1030-8 · Cited by 59 · see citing works
Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise
Casson, A. J., Vazquez Galvez, A., & Jarchi, D. (2016) · ICT Express · doi:10.1016/j.icte.2016.11.003 · Cited by 57 · see citing works
Fujita, Y., Hiromoto, M., & Sato, T. G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2697911 · Cited by 53 · see citing works
Lee, H., Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18010238 · Cited by 42 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Magnus Berggren, A., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,419 · see citing works
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Presti, D. L., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 442 · see citing works
Deep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Laerhoven, K. V. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 383 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 210 · see citing works
Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140 · see citing works
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113 · see citing works
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09597-4 · Cited by 84 · see citing works
Kwon, S., Kwon, Y., Kim, Y., Lim, H., Mahmood, M., & Yeo, W. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111981 · Cited by 76 · see citing works
Maqsood, S., Xu, S., Tran, S. N., Garg, S., Springer, M., Karunanithi, M., & Mohawesh, R. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.116788 · Cited by 78 · see citing works
Sensor-Driven Achieving of Smart Living: A Review
Leelaarporn, P., Wachiraphan, P., Kaewlee, T., Udsa, T., Chaisaen, R., Choksatchawathi, T., Laosirirat, R., Lakhan, P., Natnithikarat, P., Thanontip, K., et al. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3059304 · Cited by 64 · see citing works
Development of a PPG Sensor Array as a Wearable Device for Monitoring Cardiovascular Metrics
Rodriguez-Labra, J. I., Kosik, C. J., Maddipatla, D., Narakathu, B. B., & Atashbar, M. Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3064219 · Cited by 53 · see citing works
Rentz, L. E., Ulman, H. K., & Galster, S. M. (2021) · Sensors · doi:10.3390/s21155071 · Cited by 46 · see citing works
Wearable Bioimpedance Monitoring: Viewpoint for Application in Chronic Conditions
Groenendaal, W., Lee, S., & Hoof, C. A. V. (2021) · JMIR Biomedical Engineering · doi:10.2196/22911 · Cited by 43 · see citing works
Zeng, T., Wu, Y., & Lei, M. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-00949-9 · Cited by 40 · see citing works
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37 · see citing works
Wearable PPG Based BP Estimation Methods: A Systematic Review and Meta-Analysis
Sastimoglu, Z., Subramaniam, S., Faisal, A. I., Jiang, W., Ye, A., & Deen, M. J. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3499834 · Cited by 35 · see citing works
Ma, C., Zhang, P., Zhang, H., Liu, Z., Song, F., He, Y., & Zhang, G. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.123809 · Cited by 35 · see citing works
Deep Learning Fused Wearable Pressure and PPG Data for Accurate Heart Rate Monitoring
Mehrgardt, P., Khushi, M., Poon, S. K.-S., & Withana, A. I. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3123243 · Cited by 33 · see citing works
Wang, L., Liu, S., Li, G., & Zhu, R. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113325 · Cited by 29 · see citing works
., P., Kumar, A., Kumar, M., & Komaragiri, R. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3192831 · Cited by 29 · see citing works
Gautam, Y., & Jebelli, H. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105537 · Cited by 27 · see citing works
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30 · see citing works
Prabakaran, A., & Rufus, E. (2021) · Sensor Review · doi:10.1108/sr-05-2021-0150 · Cited by 26 · see citing works
Montanari, A., Ferlini, A., Balaji, A. N., Cecilia Mascolo, C., & Kawsar, F. (2023) · Scientific Data · doi:10.1038/s41597-023-02762-3 · Cited by 26 · see citing works
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24 · see citing works
Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach
Choksatchawathi, T., Ponglertnapakorn, P., Ditthapron, A., Leelaarporn, P., Wisutthisen, T., Piriyajitakonkij, M., & Wilaiprasitporn, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2979191 · Cited by 22 · see citing works
Lee, H., Chung, H., Kim, J.-W., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2894640 · Cited by 22 · see citing works
Self-citationA Survey of PPG's Application in Authentication
Li, L., Chen, C., Pan, L., Zhang, L. Y., Wang, Z., Zhang, J., & Xiang, Y. (2023) · Computers & Security · doi:10.1016/j.cose.2023.103488 · Cited by 24 · see citing works
Polak, A. G., Klich, B., Saganowski, S., Prucnal, M. A., & Kazienko, P. (2022) · Sensors · doi:10.3390/s22187047 · Cited by 21 · see citing works
Hosni, A., & Atef, M. (2023) · Multimedia Tools and Applications · doi:10.1007/s11042-023-14399-w · Cited by 19 · see citing works
Mahmud, S., Chowdhury, M. E. H., Serkan Kiranyaz, B., Tapotee, M. I., Saha, P., Tahir, A., Khandakar, A. A., & Alqahtani, A. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.123167 · Cited by 18 · see citing works
Seamlessly Integrable Optoelectronics for Clinical Grade Wearables
Polat, E. O. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000853 · Cited by 18 · see citing works
Real-time realizable mobile imaging photoplethysmography
Lee, H., Ko, H., Chung, H., Nam, Y., Hong, S., & Lee, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-11265-x · Cited by 17 · see citing works
Self-citationAhn, J., Ra, H.-K., Yoon, H. J., Son, S. H., & Ko, J. (2020) · IEEE Access · doi:10.1109/access.2020.3025776 · Cited by 16 · see citing works
Lee, H., Chung, H., Ko, H., Parisi, A., Busacca, A., Faes, L., Pernice, R., & Lee, J. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107126 · Cited by 14 · see citing works
Self-citationPatient-Provider Interaction System for Efficient Home-Based Cardiac Rehabilitation Exercise
Chung, H., Lee, H., Kim, C., Hong, S., & Lee, J. (2019) · IEEE Access · doi:10.1109/access.2019.2892717 · Cited by 14 · see citing works
Self-citationTufan, T. B., Rhein, L. M., & Güler, Ü. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3322871 · Cited by 12 · see citing works
Cooperative PPG/ECG Wearable System for Atrial Fibrillation Diagnosis
Lee, Y., Lee, S., Kim, S. K., Yon, D. K., Nam, Y., & Lee, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3526245 · Cited by 10 · see citing works
Self-citationEdge algorithms for wearables: an overview of a truly multi-disciplinary problem
Beach, C., Balaban, E., & Casson, A. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00014-0 · Cited by 10 · see citing works
Heart Rate Estimation from Wrist PPG Signal During Intense Physical Exercise
Hasan, K., Chowdhury, M. H., Pathan, N. S., & Hossain, Q. D. (2023) · SN Computer Science · doi:10.1007/s42979-023-02173-6 · Cited by 9 · see citing works
Kwon, T., & Yoon, S. W. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3404558 · Cited by 8 · see citing works
Wan, Y., Fawzi, A. L., & Kesari, H. (2022) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2021.114271 · Cited by 8 · see citing works
Heart rate trend forecasting during high-intensity interval training using consumer wearable devices
Fedorin, I. V., Slyusarenko, K., Pohribnyi, V., Yoon, J., Park, G., & Kim, H. (2021) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3447993.3482870 · Cited by 8 · see citing works
SigD: A Cross-Session Dataset for PPG-based User Authentication in Different Demographic Groups
Li, L., Chen, C., Pan, L., Zhang, J., & Xiang, Y. (2023) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn54540.2023.10192018 · Cited by 7 · see citing works
Fedorin, I. V., Pohribnyi, V., Sverdlov, D., & Krasnoshchok, I. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871612 · Cited by 5 · see citing works
Robust heart rate monitoring by a wearable stethoscope based on signal processing
Xu, J., Zeng, W., Zhao, C., Tong, J., & Liu, H. (2023) · Sensors & Diagnostics · doi:10.1039/d2sd00227b · Cited by 5 · see citing works
Gautam, Y., & Jebelli, H. (2024) · ASCE Construction Research Congress (CRC) · doi:10.1061/9780784485293.072 · Cited by 5 · see citing works
Raj, R., Selvakumar, J., & Maik, V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928643 · Cited by 5 · see citing works
Zhong, J., Zhou, H., LIU, Y., Cheng, X., CAI, L., Zhu, W., & Liu, L. (2021) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519421400376 · Cited by 5 · see citing works
Crupi, I., Scandelli, A., Giudici, A., & Villa, F. (2024) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas60918.2024.10636362 · Cited by 4 · see citing works
Lee, S., Lee, S., Jang, W., Kim, J., Yon, D. K., & Lee, J. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3561323 · Cited by 4 · see citing works
Self-citationOpioid Overdose Detection in a Murine Model Using a Custom-Designed Photoplethysmography Device
Hoilett, O. S., Ummel, J. D., Schepers, L. E., Soepriatna, A. H., Ma, J. L., Fujita, A., Pickering, A. S., Walters, B. D., Goergen, C. J., & Linnes, J. C. (2023) · IRBM · doi:10.1016/j.irbm.2023.100792 · Cited by 4 · see citing works
Ray, D., Collins, T., & Ponnapalli, P. V. S. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871813 · Cited by 4 · see citing works
Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring
Zhang, N., Zhang, Y., Chen, J., Qiu, S., Ma, J., Tan, L. H., & Guo, D. (2025) · Sensors · doi:10.3390/s25185910 · Cited by 3 · see citing works
Criterion Validation of an Open-source Wearable Physiological Sensors Device
Langevin, A., Bégin, W., Lavallière, M., Beaulieu, L., Ménélas, B., Gaboury, S., Bouchard, K., Gagnon, G., & Paquette, L. (2021) · International Conference on Sport Sciences Research and Technology Support (icSPORTS) · doi:10.5220/0010640300003059 · Cited by 3 · see citing works
Sicbaldi, M., Palmerini, L., Moscato, S., di Florio, P., Silvani, A., & Chiari, L. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110808 · Cited by 2 · see citing works
Fedorin, I. V., Pohribnyi, V., Sverdlov, D., & Krasnoshchok, I. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871050 · Cited by 2 · see citing works
Nakazawa, T., Morishita, K., Ienaka, A., Fujii, T., Ito, M. A., & Matsushita, F. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.10.107001 · Cited by 2 · see citing works
Ray, D., Collins, T., & Ponnapalli, P. V. S. (2022) · doi:10.36227/techrxiv.19368140 · Cited by 2 · see citing works
Camera-Based Remote Heart Rate Monitoring Using Photoplethysmography
Hosni, A., Alaryani, H. S., Almaqbali, S. A., Alsereidi, K. R., Alkaabi, N. S., Mohan, N., & Atef, M. (2024) · International Conference on Signal Processing and Information Security (ICSPIS) · doi:10.1109/icspis63676.2024.10812630 · Cited by 1 · see citing works
FlexiMA: Robust Motion Artifact Removal in PPG Signals Using an Adversarial Variational Autoencoder
Liu, Q., Zou, H., Wu, Y., Chen, Y., Ma, H., & Wang, B. (2026) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3650539 · Cited by 1 · see citing works
Nimi, W. S., Jose, P. S. H., Jose, P. S. H., Jegan, R., & El‐Shahat, A. (2022) · International Journal of Reliable and Quality E-Healthcare · doi:10.4018/ijrqeh.298632 · Cited by 2 · see citing works
Wu, M., & Chen, X. '. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-025-03379-x · Cited by 1 · see citing works
Mathematical modeling of heart rate tracking in motion affected PPG signals
Ismail, S., Akram, M. U., Siddiqi, I., & Alghamdi, N. S. (2025) · Scientific Reports · doi:10.1038/s41598-025-23446-5 · Cited by 1 · see citing works
Ray, D., Collins, T., & Ponnapalli, P. V. S. (2022) · doi:10.36227/techrxiv.19368140.v2 · Cited by 1 · see citing works
Heart Rate Estimation During Physical Exercise Using Wrist-Type Ppg Sensors
Souza, T. T. (2019) · Scholarship at UWindsor (University of Windsor)
Mobile Remote Photoplethysmography: A Real-Time Realization PerspectivePreprint
Lee, H., Ko, H., Chung, H., Nam, Y., Hong, S., & Lee, J. (2021) · Research Square · doi:10.21203/rs.3.rs-950943/v1
Self-citationRay, D., Collins, T., & Ponnapalli, P. V. S. (2022) · doi:10.36227/techrxiv.19368140.v1
(2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879203
Das, S., Biswas, U., Dastidar, S. G., & Saha, A. (2026) · Engineering Research Express · doi:10.1088/2631-8695/ae4c17
Decomposed switch mode signal assisted approach for estimating heart rate from PPG
Hasan, K., Chowdhury, M. H., Chowdhury, A., Das, D., & Hossain, Q. D. (2026) · Research on Biomedical Engineering · doi:10.1007/s42600-026-00481-3
Bridging ECG and PPG: Latent-Space Prediction for Robust Physiological Analysis
Chen, Z., Kataria, S., Wang, M., & Hu, X. (2026) · ACM SIGKDD Conference on Knowledge Discovery and Data Mining (KDD) · doi:10.1145/3770855.3819000
Clevelares, J. P. M., Oliveira, H. D., Pacheco, A. G. C., de Souza, L. A., & Villaça, R. D. S. (2026) · doi:10.5753/semish.2026.21854
- Authors
- Lee, H., Chung, H., & Lee, J.
- Affiliations
- Wonkwang University (KR)
- Venue
- IEEE Sensors Journal
- Published
- 2019-02-01
- Volume
- 19
- Issue
- 3
- Pages
- 1166-1175
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W2899602604
- Semantic Scholar
- cedc5607838d154554d7b6f1fe86858214b16175
- Cited by
- 79
- References
- 21
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 11 · 2023: 11 · 2022: 15 · 2021: 17 · 2020: 4 · 2019: 10
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Funders
- National Research Foundation of Korea
- Ministry of Science, ICT and Future Planning (NRF-2016R1D1A1B03934938, NRF-2015M3A9D7067215)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- motion artifact removal, photoplethysmography, wearable sensors, gyroscope, accelerometer, heart rate estimation, exercise monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review