Developing an algorithm for pulse oximetry derived respiratory rate (RRoxi): a healthy volunteer study
Open accessAbstract
OBJECTIVE: The presence of respiratory information within the pulse oximeter signal (PPG) is a well-documented phenomenon. However, extracting this information for the purpose of continuously monitoring respiratory rate requires: (1) the recognition of the multi-faceted manifestations of respiratory modulation components within the PPG and the complex interactions among them; (2) the implementation of appropriate advanced signal processing techniques to take full advantage of this information; and (3) the post-processing infrastructure to deliver a clinically useful reported respiratory rate to the end user. A holistic algorithmic approach to the problem is therefore required. We have developed the RR(OXI) algorithm based on this principle and its performance on healthy subject trial data is described herein. METHODS: Finger PPGs were collected from a cohort of 139 healthy adult volunteers monitored during free breathing over an 8-min period. These were subsequently processed using a novel in-house algorithm based on continuous wavelet transform technology within an infrastructure incorporating weighted averaging and logical decision making processes. The computed oximeter respiratory rates (RR(oxi)) were then compared to an end-tidal CO2 reference rate RR(ETCO2). RESULTS: RR(ETCO2) ranged from a lowest recorded value of 2.97 breaths per min (br/min) to a highest value of 28.02 br/min. The mean rate was 14.49 br/min with standard deviation of 4.36 br/min. Excellent agreement was found between RR(oxi) and RR(ETCO2), with a mean difference of -0.23 br/min and standard deviation of 1.14 br/min. The two measures are tightly spread around the line of agreement with a strong correlation observable between them (R2 = 0.93). CONCLUSIONS: These data indicate that RR(oxi) represents a viable technology for the measurement of respiratory rate of healthy individuals.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
RIIV modulates the DC baseline of the PPG curve superimposing the wave on top of a low frequency sinusoid.
“RIIV modulates the DC baseline of the PPG curve superimposing the wave on top of a low frequency sinusoid.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [121]
RIFV induces a phase shift between each cycle by elongating or squeezing each wave.
“RIFV induces a phase shift between each cycle by elongating or squeezing each wave.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [121]
RIAV causes significant changes in each peak amplitude.
“RIAV causes significant changes in each peak amplitude.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [121]
Dehkordi et al. and Addison et al. identified three significant variations to the PPG signal by respiratory rate: respiratory-induced intensity variation (RIIV), respiratory-induced amplitude variation (RIAV), and respiratory induced frequency variation (RIFV).
“Dehkordi et al. and Addison et al. identified the three significant variations to the PPG signal by respiratory rate after analyzing PPG from 139 healthy adults (67–18 years old) and the Capnobase dataset [115,121]. These variations are respiratory-induced intensity variation (RIIV), respiratory-induced amplitude variation (RIAV), and respiratory induced frequency variation (RIFV), as shown in FIG”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [121]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
The Illustrated Wavelet Transform Handbook
Addison, P. S. (2002) · Institute of Physics eBooks · doi:10.1887/0750306920 · Cited by 780 · see citing works
Self-citationThe Illustrated Wavelet Transform Handbook
Addison, P. S. (2002) · CRC Press eBooks · doi:10.1201/9781003040408 · Cited by 686 · see citing works
Self-citationEstimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 213 · see citing works
Monitoring of respiratory and heart rates using a fibre-optic sensor
Lindberg, L., Ugnell, H., & Öberg, P. Å. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457833 · Cited by 158 · see citing works
Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique
Nilsson, L. M., Johansson, A., & Kálmán, S. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011424732717 · Cited by 157 · see citing works
Neural network for photoplethysmographic respiratory rate monitoring
Johansson, A. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348427 · Cited by 109 · see citing works
Standard pulse oximeters can be used to monitor respiratory rate
Leonard, P. A. (2003) · Emergency Medicine Journal · doi:10.1136/emj.20.6.524 · Cited by 97 · see citing works
Johansson, A., Öberg, P. Å., & Sedin, G. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009912831366 · Cited by 91 · see citing works
Respiratory monitoring during pediatric sedation: pulse oximetry and capnography.
Anderson, J. A., & Vann, W. F. (1988) · PubMed · Cited by 86 · see citing works
Shelley, K. H., Alian, A. A., Stout, R. G., & Silverman, D. G. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9010-7 · Cited by 86 · see citing works
Dash, S., Shelley, K. H., Silverman, D. G., & Chon, K. H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038226 · Cited by 85 · see citing works
Nilsson, L. M., Johansson, A., & Kálmán, S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00721.x · Cited by 78 · see citing works
A Fully Automated Algorithm for the Determination of Respiratory Rate from the Photoplethysmogram
Leonard, P. A., Douglas, J. G., Grubb, N. R., Clifton, D. A., Addison, P. S., & Watson, J. N. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-9007-7 · Cited by 71 · see citing works
Self-citationAn Algorithm for the Detection of Individual Breaths from the Pulse Oximeter Waveform
Leonard, P. A., Grubb, N. R., Addison, P. S., et al. (2004) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-005-2697-z · Cited by 68 · see citing works
Self-citationExtracting breathing rate information from a wearable reflectance pulse oximeter sensor
Johnston, W. S., & Mendelson, Y. (2005) · doi:10.1109/iembs.2004.1404504 · Cited by 54 · see citing works
Forehead oximetry in critically ill patients: the case for a new monitoring site
Branson, R. D., & Mannheimer, P. D. (2004) · Respiratory Care Clinics · doi:10.1016/j.rcc.2004.04.003 · Cited by 48 · see citing works
Measurement Of Respiratory Rate From the Photoplethysmogram In Chest Clinic Patients
Clifton, D. A., Douglas, J. G., Addison, P. S., & Watson, J. N. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9059-3 · Cited by 46 · see citing works
Self-citationRespiratory Rate Extraction Via an Autoregressive Model Using the Optimal Parameter Search Criterion
Lee, J., & Chon, K. H. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0080-9 · Cited by 38 · see citing works
An automated algorithm for determining respiratory rate by photoplethysmogram in children
Leonard, P. A., Clifton, D. A., Addison, P. S., et al. (2006) · Acta Paediatrica · doi:10.1080/08035250600612280 · Cited by 36 · see citing works
Self-citationPhotoplethysmography for simultaneous recording of heart and respiratory rates in newborn infants
Olsson, E., Ugnell, H., Öberg, P. Å., & Sedin, G. (2000) · Acta Paediatrica · doi:10.1080/080352500750043774 · Cited by 31 · see citing works
Estimation of breathing interval from the photoplethysmographic signals in children
Foo, J. Y. A., & Wilson, S. J. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/014 · Cited by 30 · see citing works
Extracting respiratory data from pulse oximeter plethysmogram traces in newborn infants
Wertheim, D. F., Olden, C., Savage, E., & Seddon, P. C. (2008) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/adc.2008.145342 · Cited by 30 · see citing works
Non-invasive measurement of respiratory rate in children using the photoplethysmogram
Fleming, S., Tarassenko, L., Thompson, M., et al. (2008) · doi:10.1109/iembs.2008.4649554 · Cited by 24 · see citing works
Zhou, Y., Zheng, Y., Wang, C., et al. (2006) · Instrumentation Science & Technology · doi:10.1080/10739140600809678 · Cited by 20 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379 · see citing works
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Dehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66 · see citing works
Reducing motion artifacts in photoplethysmograms by using relative sensor motion: Phantom study
Wijshoff, R. W. C. G. R., Mischi, M., Veen, J., & Van Der Lee, A. M. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.117007 · Cited by 40 · see citing works
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33 · see citing works
- Authors
- Addison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S.
- Affiliations
- University of California, Irvine (US)
- Corresponding author
- Addison, Paul S.
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2012-01-10
- Volume
- 26
- Issue
- 1
- Pages
- 45-51
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- PMC
- PMC3268017
- OpenAlex
- W2014322746
- Cited by
- 97
- References
- 24
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 3 · 2023: 6 · 2022: 11 · 2021: 4 · 2020: 10 · 2019: 7 · 2018: 8 · 2017: 9 · 2016: 13 · 2015: 5 · 2014: 9 · 2013: 4 · 2012: 5
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- pulse oximetry, respiratory rate, photoplethysmography, continuous wavelet transform, end-tidal carbon dioxide, non-invasive respiratory monitoring, signal processing, healthy volunteers
- MeSH terms
- Adolescent, Adult, Aged, Algorithms, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Oximetry, Reference Values, Signal Processing, Computer-Assisted, Body Mass Index, Young Adult, Respiratory Rate, Wavelet Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review