Cited by 32Cardiovascular Health and Disease PreventionNon-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic Control

Parameters Extracted From Arterial Pulse Waves as Markers of Atherosclerotic Changes: Performance and Repeatability

Peltokangas, Mikko, Telembeci, Anca A., Verho, Jarmo, Mattila, Ville M., Romsi, Pekka, Vehkaoja, Antti, Lekkala, Jukka, Oksala, Niku·2018·IEEE Journal of Biomedical and Health Informatics

Abstract

Arterial diseases are significant and increasing cause of mortality and morbidity. In this study, we analyze and compare the discrimination capability of different arterial pulse wave (PW) based indices, both earlier proposed and novel ones, for describing the vascular health. The repeatability of the indices is also evaluated. Both volume PWs and dynamic pressure PWs are recorded by using photoplethysmographic and electromechanical film (EMFi) sensors connected to a wireless body sensor network. The study population consists of 82 subjects, 30 atherosclerotic patients, and 52 control subjects. In addition, day-to-day variability of the derived indices is studied with ten test subjects examined on three different days. The results are evaluated in terms of statistical tests and receiver operating characteristic (ROC) curves as well as coefficient of variation (CV) and intraclass correlation coefficient (ICC). Altogether 24 out of the evaluated 40 PW parameters showed statistical differences ( or less) between controls and atherosclerotic patients. Maximum area under curve was 0.88. Most of the indices had ICCs higher than 0.8 and average CVs less than 0.1. The study shows that the amplitude ratios and time intervals between different PW peaks could be a useful additional tool for the detection of atherosclerosis. The results encourage us for further studies in this field. Up to our knowledge, the performance and the repeatability of different PW derived indices have previously not been studied and compared with each other this extensively. Our findings also provide evidence for the utility of PW measurements for the detection of atherosclerotic changes.

Integrity signals

Registry

Crossref · 10.1109/jbhi.2017.2679904

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most investigations of the repeatability of PPG-derived parameters have taken place in laboratory settings.

    “Most investigations of the repeatability of PPG-derived parameters have taken place in laboratory settings [269].”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [269]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Peltokangas, M., Telembeci, A. A., Verho, J., Mattila, V. M., Romsi, P., Vehkaoja, A., Lekkala, J., & Oksala, N.
Affiliations
  • Tampere University of Technology (FI)
  • Tampere University (FI)
  • Oulu University Hospital (FI)
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2018-05
Volume
22
Issue
3
Pages
750-757
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2594427313
Cited by
32
References
29
Citations by year
2026: 2 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 3
FWCI
2.57
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Journal of Biomedical and Health Informatics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Tampereen Teknillinen Yliopisto
  • Finnish Funding Agency for Innovation
  • Finnish Cultural Foundation/Pirkanmaa Regional Fund/Elli and Elvi Oksanen's Fund
  • Emil Aaltonen Foundation
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
arterial pulse wave, atherosclerosis, photoplethysmography, wireless body sensor networks, repeatability, day-to-day variability, amplitude ratio, atherosclerosis detection
MeSH terms
Adult, Aged, Female, Humans, Male, Middle Aged, ROC Curve, Signal Processing, Computer-Assisted, Reproducibility of Results, Photoplethysmography, Atherosclerosis, Pulse Wave Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review