Parameters Extracted From Arterial Pulse Waves as Markers of Atherosclerotic Changes: Performance and Repeatability
Abstract
Arterial diseases are significant and increasing cause of mortality and morbidity. In this study, we analyze and compare the discrimination capability of different arterial pulse wave (PW) based indices, both earlier proposed and novel ones, for describing the vascular health. The repeatability of the indices is also evaluated. Both volume PWs and dynamic pressure PWs are recorded by using photoplethysmographic and electromechanical film (EMFi) sensors connected to a wireless body sensor network. The study population consists of 82 subjects, 30 atherosclerotic patients, and 52 control subjects. In addition, day-to-day variability of the derived indices is studied with ten test subjects examined on three different days. The results are evaluated in terms of statistical tests and receiver operating characteristic (ROC) curves as well as coefficient of variation (CV) and intraclass correlation coefficient (ICC). Altogether 24 out of the evaluated 40 PW parameters showed statistical differences ( or less) between controls and atherosclerotic patients. Maximum area under curve was 0.88. Most of the indices had ICCs higher than 0.8 and average CVs less than 0.1. The study shows that the amplitude ratios and time intervals between different PW peaks could be a useful additional tool for the detection of atherosclerosis. The results encourage us for further studies in this field. Up to our knowledge, the performance and the repeatability of different PW derived indices have previously not been studied and compared with each other this extensively. Our findings also provide evidence for the utility of PW measurements for the detection of atherosclerotic changes.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Most investigations of the repeatability of PPG-derived parameters have taken place in laboratory settings.
“Most investigations of the repeatability of PPG-derived parameters have taken place in laboratory settings [269].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [269]
Cites
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494 · see citing works
Unrepeatable Repeatabilities: A Common Mistake
Lessells, C. M., & Boag, P. T. (1987) · The Auk · doi:10.2307/4087240 · Cited by 2,919 · see citing works
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,245 · see citing works
Association Between Arterial Stiffness and Atherosclerosis: The Rotterdam Study
van Popele, N. M., Grobbee, D. E., Bots, M. L., Asmar, R., Topouchian, J., Reneman, R. S., Hoeks, A. P. G., van der Kuip, D. A. M., Hofman, A., & Witteman, J. C. M. (2001) · Stroke · doi:10.1161/01.str.32.2.454 · Cited by 1,142 · see citing works
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624 · see citing works
Xu, D., Li, J., Zou, L., Xu, Y., Hu, D., Pagoto, S., & Ma, Y. (2010) · Vascular Medicine · doi:10.1177/1358863x10378376 · Cited by 303 · see citing works
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 272 · see citing works
Predicting Arterial Stiffness From the Digital Volume Pulse Waveform
Alty, S. R., Angarita-Jaimes, N., Millasseau, S., & Chowienczyk, P. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897805 · Cited by 192 · see citing works
Schuck, P. (2004) · Quality of Life Research · doi:10.1023/b:qure.0000021318.92272.2a · Cited by 161 · see citing works
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134 · cited 1× · see citing works
“84 reported in [27].”
Review: Role of the augmentation index in hypertension
Shimizu, M., & Kario, K. (2008) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944707086935 · Cited by 105 · see citing works
de Graaff, J. C., Ubbink, D. T., Legemate, D. A., de Haan, R. J., & Jacobs, M. J. H. M. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.108011 · Cited by 104 · see citing works
Oren, A., Vos, L. E., Uiterwaal, C. S. P. M., Grobbee, D. E., & Bots, M. L. (2003) · European Journal of Clinical Investigation · doi:10.1046/j.1365-2362.2003.01259.x · Cited by 87 · see citing works
Patvardhan, E. A., Heffernan, K. S., Ruan, J., Hession, M. J., Warner, P. J., Karas, R. H., & Kuvin, J. T. (2011) · Cardiology Research and Practice · doi:10.4061/2011/253758 · Cited by 80 · see citing works
Pulse Waves : How Vascular Hemodynamics Affects Blood Pressure
Salvi, P. (2012) · Thammasat University Digital Collections · doi:10.1007/978-3-319-40501-8 · Cited by 76 · see citing works
Arterial stiffness in relation to subclinical atherosclerosis
Wykrętowicz, A., Gerstenberger, P., Guzik, P., Milewska, A., Krauze, T., Adamska, K., Rutkowska, A., & Wysocki, H. (2008) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2008.02057.x · Cited by 67 · see citing works
Salvi, P. (2012) · Springer eBooks · doi:10.1007/978-88-470-2439-7 · Cited by 54 · see citing works
Validation of the pulse decomposition analysis algorithm using central arterial blood pressure
Baruch, M. C., Kalantari, K., Gerdt, D. W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-96 · Cited by 53 · see citing works
ARTERIAL DOMINANCE IN THE HAND
Husum, B., & PALM, T. (1978) · British Journal of Anaesthesia · doi:10.1093/bja/50.9.913 · Cited by 34 · see citing works
Peltokangas, M., Vehkaoja, A. T., Verho, J. A., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2503889 · Cited by 33 · see citing works
Self-citationCrossTalk proposal: Forward and backward pressure waves in the arterial system do represent reality
Westerhof, N., & Westerhof, B. E. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.249763 · Cited by 32 · see citing works
Tyberg, J., Bouwmeester, J. C., Shrive, N. G., & Wang, J.-J. (2013) · Journal of Physiology · doi:10.1113/jphysiol.2012.249557 · Cited by 30 · see citing works
Atsma, F., Bartelink, M.-L. E. L., Grobbee, D. E., & VANDERSCHOUW, Y. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.04.005 · Cited by 29 · see citing works
Crilly, M., Coch, C., Clark, H. J., et al. (2007) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510601131946 · Cited by 28 · see citing works
Monitoring Arterial Pulse Waves With Synchronous Body Sensor Network
Peltokangas, M., Vehkaoja, A. T., Verho, J. A., et al. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328788 · Cited by 20 · see citing works
Self-citationCombining finger and toe photoplethysmograms for the detection of atherosclerosis
Peltokangas, M., Vehkaoja, A. T., Huotari, M. J., Verho, J. A., Mattila, V. M., Röning, J., Romsi, P., Lekkala, J. O., & Oksala, N. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa4eb0 · Cited by 15 · see citing works
Self-citationModified Ankle–brachial Index Detects More Patients at Risk in a Finnish Primary Health Care
Oksala, N., Viljamaa, J., Saimanen, E. I. T., & Venermo, M. A. (2009) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2009.11.007 · Cited by 14 · see citing works
Self-citationWang, J., Zhang, Y., Hu, F., et al. (2014) · Journal of Clinical Hypertension · doi:10.1111/jch.12396 · Cited by 10 · see citing works
P2.30 DOES OCCLUSION OF THE BRACHIAL ARTERY CAUSE LOCAL OSCILLATION OF ARTERIAL PRESSURE?
Korolkova, O., Parker, K. H., Davies, J. E., et al. (2012) · Artery Research · doi:10.1016/j.artres.2012.09.111 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Assessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131 · see citing works
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138 · see citing works
- Authors
- Peltokangas, M., Telembeci, A. A., Verho, J., Mattila, V. M., Romsi, P., Vehkaoja, A., Lekkala, J., & Oksala, N.
- Affiliations
- Tampere University of Technology (FI)
- Tampere University (FI)
- Oulu University Hospital (FI)
- ORCID
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-05
- Volume
- 22
- Issue
- 3
- Pages
- 750-757
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2594427313
- Cited by
- 32
- References
- 29
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 5 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 3
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Biomedical and Health Informatics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Tampereen Teknillinen Yliopisto
- Finnish Funding Agency for Innovation
- Finnish Cultural Foundation/Pirkanmaa Regional Fund/Elli and Elvi Oksanen's Fund
- Emil Aaltonen Foundation
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- arterial pulse wave, atherosclerosis, photoplethysmography, wireless body sensor networks, repeatability, day-to-day variability, amplitude ratio, atherosclerosis detection
- MeSH terms
- Adult, Aged, Female, Humans, Male, Middle Aged, ROC Curve, Signal Processing, Computer-Assisted, Reproducibility of Results, Photoplethysmography, Atherosclerosis, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review