Atrial Fibrillation Detection via Accelerometer and Gyroscope of a Smartphone
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We present a smartphone-only solution for the detection of atrial fibrillation (AFib), which utilizes the built-in accelerometer and gyroscope sensors [inertial measurement unit, (IMU)] in the detection. Depending on the patient's situation, it is possible to use the developed smartphone application either regularly or occasionally for making a measurement of the subject. The smartphone is placed on the chest of the patient who is adviced to lay down and perform a noninvasive recording, while no external sensors are needed. After that, the application determines whether the patient suffers from AFib or not. The presented method has high potential to detect paroxysmal ("silent") AFib from large masses. In this paper, we present the preprocessing, feature extraction, feature analysis, and classification results of the envisioned AFib detection system based on clinical data acquired with a standard mobile phone equipped with Google Android OS. Test data was gathered from 16 AFib patients (validated against ECG), as well as a control group of 23 healthy individuals with no diagnosed heart diseases. We obtained an accuracy of 97.4% in AFib versus healthy classification (a sensitivity of 93.8% and a specificity of 100%). Due to the wide availability of smart devices/sensors with embedded IMU, the proposed methods could potentially also scale to other domains such as embedded body-sensor networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 3×
“Finally, the approximate entropy (AP_EN) is calculated from Φ2 − Φ3 , where both ΦLD have been normalized (divided) by the total number of samples of the subsampled signal [33].”
MethodInfluential2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Abhayaratna, W. P., Seward, J. B., & Tsang, T. S. M. (2006) · Circulation · doi:10.1161/circulationaha.105.595140 · Cited by 2,564 · cited 1×
“AFib is expected to more than double in the next 50 years as the population grows older [6].”
BackgroundBallistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · cited 2×
“Our solution was based on the well known principles of seismocardiography [15], [18], [19], [22], extended with a newly proposed cardiac sensing modality gyroscope [2].”
BackgroundMethodAtrial fibrillation in women: epidemiology, pathophysiology, presentation, and prognosis
Ko, D., Rahman, F., Schnabel, R. B., Yin, X., Benjamin, E. J., & Christophersen, I. E. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.45 · Cited by 353
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
A Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
Habibzadeh, H., Dinesh, K., Rajabi Shishvan, O., Boggio-Dandry, A., Sharma, G., & Soyata, T. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2946359 · Cited by 417
Armoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Recommendations for Reporting Machine Learning Analyses in Clinical Research
Stevens, L. M., Mortazavi, B. J., Deo, R. C., Curtis, L., & Kao, D. P. (2020) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.120.006556 · Cited by 268
Metadata
- Authors
- Lahdenoja, O., Pankaala, M., Koivisto, T., Hurnanen, T., Iftikhar, Z., Nieminen, S., Knuutila, T., Saraste, A., Kiviniemi, T., Vasankari, T., & Airaksinen, J.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2018-01
- Volume
- 22
- Issue
- 1
- Pages
- 108-118
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2605145111
- Cited by
- 146
- References
- 8
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.