Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Abstract
Seismocardiography is a new noninvasive technique for recording cardiac vibrations. Changes in the recorded waves have been correlated with acute and chronic changes in left ventricular function. In this report, we describe a patient who developed ischemia induced by coronary angiography in the cardiac catheterization laboratory. The patient's seismocardiogram showed distinct changes during the ischemic episode that actually preceded the onset of symptoms and resolved after nitroglycerin therapy. The patient's seismocardiographic recordings were significantly different from the recordings from five control individuals. This observation suggests that seismocardiography may be helpful for monitoring left ventricular function during episodes of myocardial ischemia.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The z-axis accelerometer data from the chest sensor of a 1-wk-old subject contains clear information on cardiac activity, as a seismocardiogram with prominent peaks induced by Aortic valve opening and Mitral valve opening.
“For example, the z-axis accelerometer data from the chest sensor of a 1-wk-old subject (Top in Fig. 6A) contains clear information on cardiac activity, as a seismocardiogram with prominent peaks induced by Aortic valve opening (black arrow) and Mitral valve opening (gray arrow) (30–32).”
From Miniaturized wireless, skin-integrated sensor networks for quantifying full-body movement behaviors and vital signs in infants (2021) · cites this paper as [30]
Cites
Salerno, D. M., & Zanetti, J. M. (1990) · Cited by 123 · see citing works
Self-citationSCARBOROUGH, W. R., Mason, R. E., Davis, F. W., SINGEWALD, M. L., Baker, B. M., & Lore, S. A. (1952) · American Heart Journal · doi:10.1016/0002-8703(52)90095-1 · Cited by 77 · see citing works
Noninvasive diagnosis of coronary artery disease: the cardiokymographic stress test.
Silverberg, R. A., Diamond, G. A., Vas, R., Tzivoni, D., Swan, H. J. C., & Forrester, J. S. (1980) · Circulation · doi:10.1161/01.cir.61.3.579 · Cited by 57 · see citing works
Accuracy of cardiokymography during exercise testing: Results of a multicenter study
Weiner, D. A. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80105-4 · Cited by 30 · see citing works
Salemo, D. M., Zanetti, J. M., Green, L. A., et al. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)91897-4 · Cited by 9 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · see citing works
Self-citationLiu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397 · see citing works
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163 · see citing works
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114 · see citing works
Etemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95 · see citing works
“S EISMOCARDIOGRAPHY is a non-invasive technique based on measuring the micro-vibrations of the chest wall for assessing left ventricular function [1]–[4], systolic and diastolic time intervals [5]–[7], and cardio-respiratory interactions [8].”
Lin, W.-Y., Tsai, T.-H., Lee, M.-Y., Chou, W.-C., Chang, P.-C., Chou, C.-C., Wen, M.-S., Ho, M.-Y., Lee, W.-C., Hsieh, M.-J., et al. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620496 · Cited by 62 · see citing works
Jeong, H., Kwak, S. S., Sohn, S., Lee, J. Y., Lee, Y. J., O’Brien, M. K., Park, Y., Avila, R., Kim, J.-T., Yoo, J.-Y., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2104925118 · Cited by 59 · see citing works
Seismocardiogram and Ballistocardiogram Sensing
Postolache, O., Girão, P., & Postolache, G. (2013) · Advanced Instrument Engineering · doi:10.4018/978-1-4666-4165-5.ch017 · Cited by 5 · see citing works
- Authors
- Salerno, D. M., & Zanetti, J.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Salerno, David M.
- ORCID
- Salerno, David M.
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 100
- Issue
- 4
- Pages
- 991-993
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W2094437655
- Cited by
- 149
- References
- 5
- Citations by year
- 2026: 6 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 7 · 2021: 9 · 2020: 12 · 2019: 13 · 2018: 6 · 2017: 12 · 2016: 14 · 2015: 6 · 2014: 7 · 2013: 11 · 2012: 4
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- CHEST Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- seismocardiography, left ventricular function, myocardial ischemia, coronary angiography complications, cardiac vibrations, nitroglycerin, non-invasive cardiac monitoring
- MeSH terms
- Coronary Disease, Electrocardiography, Female, Cardiac Catheterization, Heart Function Tests, Humans, Kinetocardiography, Middle Aged, Pulmonary Wedge Pressure, Ventricular Function, Left, Coronary Angiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review