Cited by 149Phonocardiography and Auscultation TechniquesNon-Invasive Vital Sign MonitoringCardiovascular Function and Risk Factors

Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia

Salerno, David M., Zanetti, John·1991·Chest

Abstract

Seismocardiography is a new noninvasive technique for recording cardiac vibrations. Changes in the recorded waves have been correlated with acute and chronic changes in left ventricular function. In this report, we describe a patient who developed ischemia induced by coronary angiography in the cardiac catheterization laboratory. The patient's seismocardiogram showed distinct changes during the ischemic episode that actually preceded the onset of symptoms and resolved after nitroglycerin therapy. The patient's seismocardiographic recordings were significantly different from the recordings from five control individuals. This observation suggests that seismocardiography may be helpful for monitoring left ventricular function during episodes of myocardial ischemia.

Integrity signals

Registry

Crossref · 10.1378/chest.100.4.991

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The z-axis accelerometer data from the chest sensor of a 1-wk-old subject contains clear information on cardiac activity, as a seismocardiogram with prominent peaks induced by Aortic valve opening and Mitral valve opening.

    “For example, the z-axis accelerometer data from the chest sensor of a 1-wk-old subject (Top in Fig. 6A) contains clear information on cardiac activity, as a seismocardiogram with prominent peaks induced by Aortic valve opening (black arrow) and Mitral valve opening (gray arrow) (30–32).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Salerno, D. M., & Zanetti, J.
Affiliations
University of Minnesota (US)
Corresponding author
Salerno, David M.
Venue
Chest
Publisher
Elsevier BV
Published
1991-10
Volume
100
Issue
4
Pages
991-993
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2094437655
Cited by
149
References
5
Citations by year
2026: 6 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 7 · 2021: 9 · 2020: 12 · 2019: 13 · 2018: 6 · 2017: 12 · 2016: 14 · 2015: 6 · 2014: 7 · 2013: 11 · 2012: 4
FWCI
0.49
Type
journal article
Language
en
Open access
closed
Locations
  • CHEST Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
seismocardiography, left ventricular function, myocardial ischemia, coronary angiography complications, cardiac vibrations, nitroglycerin, non-invasive cardiac monitoring
MeSH terms
Coronary Disease, Electrocardiography, Female, Cardiac Catheterization, Heart Function Tests, Humans, Kinetocardiography, Middle Aged, Pulmonary Wedge Pressure, Ventricular Function, Left, Coronary Angiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review