CoChat

Automatic Screening of Sleep Apnea Patients Based on the SpO2 Signal

Open access
Deviaene, Margot, Testelmans, Dries, Buyse, Bertien, Borzee, Pascal, Van Huffel, Sabine, Varon, Carolina · 2019 · IEEE Journal of Biomedical and Health Informatics
Cited by 75

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objective: This paper presents a methodology to automatically screen for sleep apnea based on the detection of apnea and hypopnea events in the blood oxygen saturation (SpO2) signal. Methods: It starts by detecting all desaturations in the SpO2signal. From these desaturations, a total of 143 time-domain features are extracted. After feature selection, the six most discriminative features are used to construct classifiers to predict if desaturations are caused by respiratory events. From these, a random forest classifier yielded the best classification performance. The number of desaturations, classified as caused by respiratory events per hour of recording, can then be used as an estimate of the apnea-hypopnea index (AHI), and to predict whether or not a patient suffers from sleep apneahypopnea syndrome (SAHS). All classifiers were developed based on a subset of 500 subjects of the Sleep Heart Health Study (SHHS) and tested on three different datasets, containing 8052 subjects in total. Results: An averaged desaturation classification accuracy of 82.8% was achieved over the different test sets. Subjects having SAHS with an AHI greater than 15 can be detected with an average accuracy of 87.6%. Conclusion: The achieved SAHS screening outperforms SpO2methods from the literature on the SHHS test dataset. Moreover, the robustness of the method was shown when tested on different independent test sets. Significance: These results show that an algorithm based on simple features of SpO2desaturations can outperform more elaborate methods in the detection of apneic events and the screening of SAHS patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2018.2817368

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 75

Metadata

Authors
Deviaene, M., Testelmans, D., Buyse, B., Borzee, P., Van Huffel, S., & Varon, C.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2019-03
Volume
23
Issue
2
Pages
607-617
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2793659206
Cited by
75
References
8
FWCI
4.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic Screening of Sleep Apnea Patients Based on the SpO2 Signal. https://app.cochat.ai/papers/10.1109/jbhi.2018.2817368
The paper
Deviaene, M., Testelmans, D., Buyse, B., Borzee, P., Van Huffel, S., & Varon, C. (2019). Automatic Screening of Sleep Apnea Patients Based on the SpO2 Signal. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2018.2817368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.