Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 189

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Sparse Group Representation Model for Motor Imagery EEG Classification

Jiao, Yong, Zhang, Yu, Chen, Xun, Yin, Erwei, Jin, Jing, Wang, Xingyu, Cichocki, Andrzej · 2019 · IEEE Journal of Biomedical and Health Informatics

Abstract

A potential limitation of a motor imagery (MI) based brain-computer interface (BCI) is that it usually requires a relatively long time to record sufficient electroencephalogram (EEG) data for robust classifier training. The calibration burden during data acquisition phase will most probably cause a subject to be reluctant to use a BCI system. To alleviate this issue, we propose a novel sparse group representation model (SGRM) for improving the efficiency of MI-based BCI by exploiting the intersubject information. Specifically, preceded by feature extraction using common spatial pattern, a composite dictionary matrix is constructed with training samples from both the target subject and other subjects. By explicitly exploiting within-group sparse and group-wise sparse constraints, the most compact representation of a test sample of the target subject is then estimated as a linear combination of columns in the dictionary matrix. Classification is implemented by calculating the class-specific representation residual based on the significant training samples corresponding to the nonzero representation coefficients. Accordingly, the proposed SGRM method effectively reduces the required training samples from the target subject due to auxiliary data available from other subjects. With two public EEG data sets, extensive experimental comparisons are carried out between SGRM and other state-of-the-art approaches. Superior classification performance of our method using 40 trials of the target subject for model calibration (Averaged accuracy = 78.2%, Kappa = 0.57 and Averaged accuracy = 77.7%, Kappa = 0.55 for the two data sets, respectively) indicates its promising potential for improving the practicality of MI-based BCI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jbhi.2018.2832538

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 189

Metadata

Authors
Jiao, Y., Zhang, Y., Chen, X., Yin, E., Jin, J., Wang, X., & Cichocki, A.
Venue
IEEE Journal of Biomedical and Health Informatics
Published
2019-03
Volume
23
Issue
2
Pages
631-641
ISSN
  • 2168-2194 (ISSN-L)
  • 2168-2208
OpenAlex
W2802723950
Cited by
189
References
13
FWCI
14.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sparse Group Representation Model for Motor Imagery EEG Classification. https://app.cochat.ai/papers/10.1109/jbhi.2018.2832538
The paper
Jiao, Y., Zhang, Y., Chen, X., Yin, E., Jin, J., Wang, X., & Cichocki, A. (2019). Sparse Group Representation Model for Motor Imagery EEG Classification. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2018.2832538

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.