Sparse Group Representation Model for Motor Imagery EEG Classification
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
A potential limitation of a motor imagery (MI) based brain-computer interface (BCI) is that it usually requires a relatively long time to record sufficient electroencephalogram (EEG) data for robust classifier training. The calibration burden during data acquisition phase will most probably cause a subject to be reluctant to use a BCI system. To alleviate this issue, we propose a novel sparse group representation model (SGRM) for improving the efficiency of MI-based BCI by exploiting the intersubject information. Specifically, preceded by feature extraction using common spatial pattern, a composite dictionary matrix is constructed with training samples from both the target subject and other subjects. By explicitly exploiting within-group sparse and group-wise sparse constraints, the most compact representation of a test sample of the target subject is then estimated as a linear combination of columns in the dictionary matrix. Classification is implemented by calculating the class-specific representation residual based on the significant training samples corresponding to the nonzero representation coefficients. Accordingly, the proposed SGRM method effectively reduces the required training samples from the target subject due to auxiliary data available from other subjects. With two public EEG data sets, extensive experimental comparisons are carried out between SGRM and other state-of-the-art approaches. Superior classification performance of our method using 40 trials of the target subject for model calibration (Averaged accuracy = 78.2%, Kappa = 0.57 and Averaged accuracy = 77.7%, Kappa = 0.55 for the two data sets, respectively) indicates its promising potential for improving the practicality of MI-based BCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Face Recognition via Sparse Representation
Wright, J., Yang, A. Y., Ganesh, A., Sastry, S. S., & Ma, Y. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.79 · Cited by 9,388 · cited 4×
“representation-based classification (SRC) scheme, which was first proposed by Wright et al.[37] for robust face recognition.”
InfluentialBrain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“man brain and a computer [1].”
Model Selection and Estimation in Regression with Grouped Variables
Yuan, M., & Lin, Y. (2006) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2005.00532.x · Cited by 7,261 · cited 8×
“On the other hand, SGRM will reduce to the standard Lasso problem with λ2 = 0 and be unable to exclude those subjects which generate quite different feature distributions from the target subject, which may also result in inaccurate classification.”
InfluentialAtomic Decomposition by Basis Pursuit
Chen, S. S., Donoho, D. L., & Saunders, M. A. (2001) · SIAM Review · doi:10.1137/s003614450037906x · Cited by 5,085
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 1×
“that is able to provide good generalization ability for accurate EEG classification [30].”
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 2×
“signal processing algorithm, which has been proved to be effective in extracting discriminative features from multi-channel EEG for MI classification [26].”
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 2×
“(CSP) is one of the most popular spatial filtering methods for MI-related EEG feature extraction [21].”
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264 · cited 2×
“for achieving high classification accuracy of SMR has been one of the research hotspots in the BCI field [24], [25].”
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Regularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045 · cited 1×
“applications [28], [29].”
Medical Image Synthesis with Deep Convolutional Adversarial Networks
Nie, D., Trullo, R., Lian, J., Wang, L., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2814538 · Cited by 625
A note on the group lasso and a sparse group lasso
Friedman, J. H., Hastie, T. J., & Tibshirani, R. J. (2010) · arXiv (Cornell University) · doi:10.48550/arxiv.1001.0736 · Cited by 619 · cited 4×
“the standard SRC scheme that uses the L1-norm regularization only, the proposed SGRM method simultaneously exploits both L2,1-norm [49] and L1-norm to control the group-wise sparsity and within-group sparsity, respectively.”
InfluentialLatent Multi-view Subspace Clustering
Zhang, C., Hu, Q., Fu, H., Zhu, P., & Cao, X. (2017) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2017.461 · Cited by 611
Towards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501 · cited 6×
“For example, multisubject based covariance matrix estimation has been designed for both CSP feature extraction and LDA classification to reduce the calibration time of BCI system [38], [45], [48].”
InfluentialNoninvasive Electroencephalogram Based Control of a Robotic Arm for Reach and Grasp Tasks
Meng, J., Zhang, S., Bekyo, A., Olsoe, J., Baxter, B., & He, B. (2016) · Scientific Reports · doi:10.1038/srep38565 · Cited by 484 · cited 2×
“Meng et al.[14] introduced a BCI robotic arm system, allowing subjects to efficiently manipulate a robotic arm in a 3D space by modulating their brain rhythms.”
Real-time detection of brain events in EEG
Vidal, J. J. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10542 · Cited by 457
Optimizing the Channel Selection and Classification Accuracy in EEG-Based BCI
Arvaneh, M., Guan, C., Ang, K. K., & Quek, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2131142 · Cited by 424 · cited 1×
“for MI-based EEG classification [29], [52], [53].”
FREQUENCY RECOGNITION IN SSVEP-BASED BCI USING MULTISET CANONICAL CORRELATION ANALYSIS
ZHANG, Y., ZHOU, G., JIN, J., WANG, X., & CICHOCKI, A. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500130 · Cited by 357
Self-citationRobust Joint Graph Sparse Coding for Unsupervised Spectral Feature Selection
Zhu, X., Li, X., Zhang, S., Ju, C., & Wu, X. (2017) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2016.2521602 · Cited by 339 · cited 1×
“an increasing number of subspace regularization algorithms [67]–[70] have arisen for various applications including imaging processing, brain disease diagnosis [71]–[76].”
Lotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 2×
“vestigated using signal segmentation and recombination in time or time-frequency domain, or based on analogy [44].”
A New Discriminative Common Spatial Pattern Method for Motor Imagery Brain–Computer Interfaces
Thomas, K. P., Guan, C., Lau, C. T., Vinod, A. P., & Ang, K. K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2026181 · Cited by 321 · cited 1×
“for MI-based EEG classification [29], [52], [53].”
Regularized Common Spatial Pattern With Aggregation for EEG Classification in Small-Sample Setting
Lu, H., Eng, H.-L., Guan, C., Plataniotis, K. N., & Venetsanopoulos, A. N. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082540 · Cited by 309 · cited 2×
“thereby substantially deteriorating the system’s practicality and even causing a subject to be reluctant to use BCI [25], [38], [39].”
Toward Unsupervised Adaptation of LDA for Brain–Computer Interfaces
Vidaurre, C., Kawanabe, M., von Bünau, P., Blankertz, B., & Müller, K. R. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2093133 · Cited by 296 · cited 1×
“data newly available during use, semi-supervised learning provides an effective way to refine the calibration of BCI using a well-designed adaptive approach [47].”
EEG-Based Strategies to Detect Motor Imagery for Control and Rehabilitation
Ang, K. K., & Guan, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2646763 · Cited by 289 · cited 1×
“been developed for EEG analysis in various BCI applications [16], [56]–[63].”
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267 · cited 1×
“been developed for EEG analysis in various BCI applications [16], [56]–[63].”
Self-citationZhang, Y., Zhou, G., Jin, J., Wang, X., & Cichocki, A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.004 · Cited by 266 · cited 1×
“An increasing number of studies [24], [50], [51] have suggested that the multi-band CSP”
Self-citationComposite Common Spatial Pattern for Subject-to-Subject Transfer
Kang, H., Nam, Y., & Choi, S. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2022557 · Cited by 265 · cited 1×
“for both CSP feature extraction and LDA classification to reduce the calibration time of BCI system [38], [45], [48].”
Frequency recognition in SSVEP-based BCI using multiset canonical correlation analysisPreprint
Zhang, Y., Zhou, G., Jin, J., Wang, X., & Cichocki, A. S. (2014) · Cited by 264
Self-citationSparse Bayesian Classification of EEG for Brain–Computer Interface
Zhang, Y., Zhou, G., Jin, J., Zhao, Q., Wang, X., & Cichocki, A. (2016) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2015.2476656 · Cited by 264 · cited 1×
“In recent years, sparse Bayesian learning has shown its promise in enhancing the efficiency of EEG classification for BCI applications [50], [64]–[66], since it provides an effective way to automatically determine the optimal model parameters under the evidence framework.”
Self-citationMulti-kernel extreme learning machine for EEG classification in brain-computer interfaces
Zhang, Y., Wang, Y., Zhou, G., Jin, J., Wang, B., Wang, X., & Cichocki, A. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.12.015 · Cited by 255 · cited 1×
“recordings [20].”
Self-citationSoekadar, S. R., Witkowski, M., Gómez, C., Opisso, E., Medina, J., Cortese, M., Cempini, M., Carrozza, M. C., Cohen, L. G., Birbaumer, N., et al. (2016) · Science Robotics · doi:10.1126/scirobotics.aag3296 · Cited by 242 · cited 1×
“[13] proposed a hybrid EEG/EOG-based brain/neural-assistive technology for restoring independent daily living activities of”
Xu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227 · cited 1×
“So far, the mostly used neural response patterns for BCI development include sensorimotor rhythm (SMR), steady-state visual evoked potential (SSVEP), and event-related potential (ERP) [15]–[19].”
Zhu, X., Suk, H.-I., Lee, S.-W., & Shen, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466616 · Cited by 218
Ma, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209
Self-citationZhang, Y., Wang, Y., Jin, J., & Wang, X. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065716500325 · Cited by 201
Self-citationThe Use of Multivariate EMD and CCA for Denoising Muscle Artifacts From Few-Channel EEG Recordings
Chen, X., Xu, X., Liu, A., McKeown, M. J., & Wang, Z. J. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2759398 · Cited by 196
Self-citationProbabilistic Common Spatial Patterns for Multichannel EEG Analysis
Wu, W., Chen, Z., Gao, X., Li, Y., Brown, E. N., & Gao, S. (2015) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2014.2330598 · Cited by 194 · cited 1×
“In recent years, sparse Bayesian learning has shown its promise in enhancing the efficiency of EEG classification for BCI applications [50], [64]–[66], since it provides an effective way to automatically determine the optimal model parameters under the evidence framework.”
Siuly, S., & Li, Y. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2184838 · Cited by 191 · cited 1×
“With CSP features, SVM provides state-of-the-art performance for SMR classification [33].”
3-D Fully Convolutional Networks for Multimodal Isointense Infant Brain Image Segmentation
Nie, D., Wang, L., Adeli, E., Lao, C., Lin, W., & Shen, D. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2797905 · Cited by 191
Wang, G., Teng, C., Li, K., Zhang, Z., & Yan, X. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2450196 · Cited by 189
Linked Component Analysis From Matrices to High-Order Tensors: Applications to Biomedical Data
Zhou, G., Zhao, Q., Zhang, Y., Adali, T., Xie, S., & Cichocki, A. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2474704 · Cited by 186 · cited 1×
“an increasing number of subspace regularization algorithms [67]–[70] have arisen for various applications including imaging processing, brain disease diagnosis [71]–[76].”
Self-citationXu, R., Jiang, N., Mrachacz-Kersting, N., Lin, C., Asin Prieto, G., Moreno, J. C., Pons, J. L., Dremstrup, K., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2313867 · Cited by 185
FORCe: Fully online and automated artifact removal for brain-computer interfacing
Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346621 · Cited by 174 · cited 1×
“likely to be contaminated by noises resulted from body movements, eye blinks or other environment interferences [21]–[23].”
Simultaneous Design of FIR Filter Banks and Spatial Patterns for EEG Signal Classification
Higashi, H., & Tanaka, T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2215960 · Cited by 171 · cited 1×
“signals from one class while minimizing it from another class [26], [27].”
Park, S.-H., Lee, D., & Lee, S.-G. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2757519 · Cited by 170 · cited 2×
“thereby substantially deteriorating the system’s practicality and even causing a subject to be reluctant to use BCI [25], [38], [39].”
A novel BCI based on ERP components sensitive to configural processing of human faces
Zhang, Y., Zhao, Q., Jing, J., Wang, X., & Cichocki, A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026018 · Cited by 156 · cited 1×
“ternal devices such as a wheelchair, an artificial limb, a spelling system, and so on [9]–[11].”
Self-citationSpatial-Temporal Discriminant Analysis for ERP-Based Brain-Computer Interface
Zhang, Y., Zhou, G., Zhao, Q., Jin, J., Wang, X., & Cichocki, A. S. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2243471 · Cited by 150
Self-citationFlexible Multi-View Dimensionality Co-Reduction
Zhang, C., Fu, H., Hu, Q., Zhu, P., & Cao, X. (2016) · IEEE Transactions on Image Processing · doi:10.1109/tip.2016.2627806 · Cited by 147
Discriminative Feature Extraction via Multivariate Linear Regression for SSVEP-Based BCI
Wang, H., Zhang, Y., Waytowich, N. R., Krusienski, D. J., Zhou, G., Jin, J., Wang, X., & Cichocki, A. S. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2519350 · Cited by 147
Self-citationLearning from other subjects helps reducing Brain-Computer Interface calibration time
Lotte, F., & Guan, C. (2010) · 2010 IEEE International Conference on Acoustics, Speech and Signal Processing · doi:10.1109/icassp.2010.5495183 · Cited by 144
A P300 Brain–Computer Interface Based on a Modification of the Mismatch Negativity Paradigm
Jin, J., Sellers, E. W., Zhou, S., Zhang, Y., Wang, X., & Cichocki, A. S. (2015) · International Journal of Neural Systems · doi:10.1142/s0129065715500112 · Cited by 139
Self-citationStrength and similarity guided group-level brain functional network construction for MCI diagnosis
Zhang, Y., Zhang, H., Chen, X., Liu, M., Zhu, X., Lee, S.-W., & Shen, D. (2019) · Pattern Recognition · doi:10.1016/j.patcog.2018.12.001 · Cited by 135
Self-citationA Hybrid Brain–Computer Interface Based on the Fusion of P300 and SSVEP Scores
Yin, E., Zeyl, T., Saab, R., Chau, T., Hu, D., & Zhou, Z. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2403270 · Cited by 120 · cited 1×
“mental tasks [2]–[8].”
Self-citationCorrelated Component Analysis for Enhancing the Performance of SSVEP-Based Brain-Computer Interface
Zhang, Y., Guo, D., Li, F., Yin, E., Zhang, Y., Li, P., Zhao, Q., Tanaka, T., Yao, D., & Xu, P. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2826541 · Cited by 116
Self-citationDong, E., Li, C., Li, L., Du, S., Belkacem, A. N., & Chen, C. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1611-4 · Cited by 113 · cited 1×
“for MI-based EEG classification [29], [52], [53].”
Joint Blind Source Separation for Neurophysiological Data Analysis: Multiset and multimodal methods
Chen, X., Wang, Z. J., & McKeown, M. J. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2016.2521870 · Cited by 105
Self-citationChai, R., Ling, S. H., Hunter, G. P., Tran, Y., & Nguyen, H. T. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2295006 · Cited by 102 · cited 1×
“ternal devices such as a wheelchair, an artificial limb, a spelling system, and so on [9]–[11].”
SSVEP recognition using common feature analysis in brain–computer interface
Zhang, Y., Zhou, G., Jin, J., Wang, X., & Cichocki, A. S. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.03.012 · Cited by 101
Self-citationJiao, Y., Zhang, Y., Wang, Y., Wang, B., Jin, J., & Wang, X. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065717500393 · Cited by 96 · cited 1×
“been developed for EEG analysis in various BCI applications [16], [56]–[63].”
Self-citationZhang, Y., Zhou, G., Jin, J., Zhao, Q., Wang, X., & Cichocki, A. S. (2013) · International Journal of Neural Systems · doi:10.1142/s0129065714500038 · Cited by 95 · cited 1×
“thereby substantially deteriorating the system’s practicality and even causing a subject to be reluctant to use BCI [25], [38], [39].”
Self-citationShin, Y., Lee, S., Lee, J.-H., & Lee, H.-N. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056002 · Cited by 92 · cited 10×
“For example, multisubject based covariance matrix estimation has been designed for both CSP feature extraction and LDA classification to reduce the calibration time of BCI system [38], [45], [48].”
InfluentialSparse Representation for Brain Signal Processing: A tutorial on methods and applications
Li, Y., Yu, Z. L., Bi, N., Xu, Y., Gu, Z., & Амари, Ш.-И. (2014) · IEEE Signal Processing Magazine · doi:10.1109/msp.2013.2296790 · Cited by 82 · cited 1×
“More recently, sparse representation has attracted increasing interests of researchers in the fields of neural information processing [34], [35].”
Combined corticospinal and reticulospinal effects on upper limb muscles
Ortiz-Rosario, A., Berrios-Torres, I., Adeli, H., & Buford, J. A. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2013.12.043 · Cited by 75 · cited 1×
“nal environment by a BCI system instead of the traditional output forms such as peripheral nerves and muscle movements [12].”
Low-Rank Graph-Regularized Structured Sparse Regression for Identifying Genetic Biomarkers
Zhu, X., Suk, H., Huang, H., & Shen, D. G. (2017) · IEEE Transactions on Big Data · doi:10.1109/tbdata.2017.2735991 · Cited by 75 · cited 1×
“an increasing number of subspace regularization algorithms [67]–[70] have arisen for various applications including imaging processing, brain disease diagnosis [71]–[76].”
Multi-Hypergraph Learning for Incomplete Multimodality Data
Liu, M., Gao, Y., Yap, P., & Shen, D. G. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2732287 · Cited by 74 · cited 1×
“an increasing number of subspace regularization algorithms [67]–[70] have arisen for various applications including imaging processing, brain disease diagnosis [71]–[76].”
Sparse Bayesian multiway canonical correlation analysis for EEG pattern recognition
Zhang, Y., Zhou, G., Jin, J., Zhang, Y., Wang, X., & Cichocki, A. S. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.11.008 · Cited by 63 · cited 2×
“An increasing number of studies [24], [50], [51] have suggested that the multi-band CSP”
Self-citationP300-Based Asynchronous Brain Computer Interface for Environmental Control System
Aydın, E. A., Bay, Ö. F., & Güler, İ. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2690801 · Cited by 59
Whether generic model works for rapid ERP-based BCI calibration
Jin, J., Sellers, E. W., Zhang, Y., Daly, I. P., Wang, X., & Cichocki, A. S. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.09.020 · Cited by 55 · cited 1×
“end, several different approaches have been suggested, including semi-supervised learning [42], [43], artificial data generation [44], and subject-to-subject transfer [45], [46].”
Self-citationAn Online Semi-supervised Brain–Computer Interface
Gu, Z., Yu, Z., Shen, Z., & Li, Y. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2261994 · Cited by 53 · cited 1×
“end, several different approaches have been suggested, including semi-supervised learning [42], [43], artificial data generation [44], and subject-to-subject transfer [45], [46].”
An Efficient P300-based Brain-Computer Interface with Minimal Calibration Time
Lotte, F., & Guan, C. (2009) · HAL · Cited by 33
A Sparse Representation-Based Algorithm for Pattern Localization in Brain Imaging Data Analysis
Li, Y., Long, J., He, L., Lu, H. D., Gu, Z., & Sun, P. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050332 · Cited by 33 · cited 1×
“More recently, sparse representation has attracted increasing interests of researchers in the fields of neural information processing [34], [35].”
Long, J., Li, Y., & Yu, Z. (2010) · Cognitive Neurodynamics · doi:10.1007/s11571-010-9114-0 · Cited by 27 · cited 1×
“end, several different approaches have been suggested, including semi-supervised learning [42], [43], artificial data generation [44], and subject-to-subject transfer [45], [46].”
Higashi, H., Rutkowski, T. M., Tanaka, T., & Tanaka, Y. (2016) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2016.2599297 · Cited by 23 · cited 1×
“to improve the single-trial event-related potential classification [77].”
Canonical Polyadic Decomposition With Auxiliary Information for Brain–Computer Interface
Li, J., Li, C., & Cichocki, A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2491645 · Cited by 20 · cited 4×
“[46] J. Jin, E. W. Sellers, Y. Zhang, I. Daly, X. Wang, and A. Cichocki, “Whether generic model works for rapid ERP-based BCI calibration,” J. Neurosci.”
InfluentialSelf-citationEvaluation of Healthy EEG Responses for Spelling Through Listener-Assisted Scanning
Horki, P., Klobassa, D. S., Pokorny, C., & Müller-Putz, G. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328494 · Cited by 10
Cited by
Temporally Constrained Sparse Group Spatial Patterns for Motor Imagery BCI
Zhang, Y., Nam, C. S., Zhou, G., Jin, J., Wang, X., & Cichocki, A. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2841847 · Cited by 330
Self-citationReview of Machine Learning Techniques for EEG Based Brain Computer Interface
Aggarwal, S., & Chugh, N. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09684-6 · Cited by 270
Internal Feature Selection Method of CSP Based on L1-Norm and Dempster–Shafer Theory
Jin, J., Xiao, R., Daly, I., Miao, Y., Wang, X., & Cichocki, A. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3015505 · Cited by 267
Self-citationSingh, A., Hussain, A. A., Lal, S., & Guesgen, H. W. (2021) · Sensors · doi:10.3390/s21062173 · Cited by 192
MIN2Net: End-to-End Multi-Task Learning for Subject-Independent Motor Imagery EEG Classification
Autthasan, P., Chaisaen, R., Sudhawiyangkul, T., Rangpong, P., Kiatthaveephong, S., Dilokthanakul, N., Bhakdisongkhram, G., Phan, H., Guan, C., & Wilaiprasitporn, T. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3137184 · Cited by 187
“Some works that utilize minimum training samples have been proposed and validated on several MI datasets [33], [34].”
Background
Metadata
- Authors
- Jiao, Y., Zhang, Y., Chen, X., Yin, E., Jin, J., Wang, X., & Cichocki, A.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019-03
- Volume
- 23
- Issue
- 2
- Pages
- 631-641
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2802723950
- Cited by
- 189
- References
- 76
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.