Accurate Deep Learning-Based Sleep Staging in a Clinical Population with Suspected Obstructive Sleep Apnea
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
The identification of sleep stages is essential in the diagnostics of sleep disorders, among which obstructive sleep apnea (OSA) is one of the most prevalent. However, manual scoring of sleep stages is time-consuming, subjective, and costly. To overcome this shortcoming, we aimed to develop an accurate deep learning approach for automatic classification of sleep stages and to study the effect of OSA severity on the classification accuracy. Overnight polysomnographic recordings from a public dataset of healthy individuals (Sleep-EDF, n = 153) and from a clinical dataset (n = 891) of patients with suspected OSA were used to develop a combined convolutional and long short-term memory neural network. On the public dataset, the model achieved sleep staging accuracy of 83.7% (κ = 0.77) with a single frontal EEG channel and 83.9% (κ = 0.78) when supplemented with EOG. For the clinical dataset, the model achieved accuracies of 82.9% (κ = 0.77) and 83.8% (κ = 0.78) with a single EEG channel and two channels (EEG+EOG), respectively. The sleep staging accuracy decreased with increasing OSA severity. The single-channel accuracy ranged from 84.5% (κ = 0.79) for individuals without OSA diagnosis to 76.5% (κ = 0.68) for patients with severe OSA. In conclusion, deep learning enables automatic sleep staging for suspected OSA patients with high accuracy and expectedly, the accuracy decreased with increasing OSA severity. Furthermore, the accuracies achieved in the public dataset were superior to previously published state-of-the-art methods. Adding an EOG channel did not significantly increase the accuracy. The automatic, single-channel-based sleep staging could enable easy, accurate, and cost-efficient integration of EEG recording into diagnostic ambulatory recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148 · cited 2×
“[39] J. R. Landis and G. G. Koch, “The measurement of observer agreement for categorical data,” Biometrics, vol. 33, no. 1, pp. 159–174, 1977.”
MethodA Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398 · cited 1×
“Moreover, the inter-rater agreement between manual and automatic sleep staging was evaluated using Cohen’s kappa coefficient (κ) [38] and the sensitivity and specificity of differentiating sleep from wake sleep were calculated.”
MethodGoldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
(2007) · Cited by 6,530
SGDR: Stochastic Gradient Descent with Warm Restarts
Loshchilov, I., & Hutter, F. (2016) · arXiv · doi:10.48550/arxiv.1608.03983 · Cited by 5,309 · cited 1×
“and an Adam optimizer with warm restarts [36] using a learning rate range of 0.”
MethodAllan Hobson, J. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90021-2 · Cited by 5,192
(1999) · Sleep · doi:10.1093/sleep/22.5.667 · Cited by 5,147 · cited 2×
“According to the current severity classification of OSA, based on apnea-hypopnea index (AHI) [35], 152 individuals had no OSA (5 AHI), 278 suffered from mild OSA (5 ≤ AHI 15), 208 from moderate OSA (15 ≤ AHI 30), and 254 had severe OSA (AHI ≥ 30).”
MethodCyclical Learning Rates for Training Neural Networks
Smith, L. N. (2017) · 2017 IEEE Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv.2017.58 · Cited by 2,670 · cited 1×
“This learning rate range was optimized with a learning rate finder [37].”
MethodPrevalence of obstructive sleep apnea in the general population: A systematic review
Senaratna, C. V., Perret, J. L., Lodge, C. J., Lowe, A. J., Campbell, B. E., Matheson, M. C., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.07.002 · Cited by 2,581 · cited 1×
“One of the most common sleep disorders is obstructive sleep apnea (OSA) which has been estimated to affect up to 38% of the general population [1].”
BackgroundDeepSleepNet: a model for automatic sleep stage scoring based on raw single-channel EEG
Supratak, A., Dong, H., Wu, C., & Guo, Y. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2721116 · Cited by 1,376 · cited 6×
“amount of wake either by using only 30 minutes of wake before and after sleep [11], [18] or by only using the sleep [19], [20], [21].”
BackgroundMethodResultInfluentialAnalysis of a sleep-dependent neuronal feedback loop: the slow-wave microcontinuity of the EEG
Kemp, B., Zwinderman, A. H., Tuk, B., Kamphuisen, H. A. C., & Oberye, J. J. L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867928 · Cited by 953 · cited 1×
“1) Sleep-EDF: We first utilized a public dataset, Physionet Sleep-EDF [32], [33], to allow comparison of the proposed deep learning-based approach with previous state-of-the-art methods.”
MethodAccess to Diagnosis and Treatment of Patients with Suspected Sleep Apnea
Flemons, W. W., Douglas, N. J., Kuna, S. T., Rodenstein, D. O., & Wheatley, J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1124pp · Cited by 670 · cited 1×
“Ambulatory recordings are even the preferred diagnostic method in some healthcare systems [42], [43].”
MethodA manual of Standardized Terminology
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 632
Phan, H., Andreotti, F., Cooray, N., Chen, O. Y., & De Vos, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896659 · Cited by 623
SleepEEGNet: Automated sleep stage scoring with sequence to sequence deep learning approach
Mousavi, S., Afghah, F., & Acharya, U. R. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216456 · Cited by 531 · cited 4×
“amount of wake either by using only 30 minutes of wake before and after sleep [11], [18] or by only using the sleep [19], [20], [21].”
BackgroundMethodResultInfluentialJoint Classification and Prediction CNN Framework for Automatic Sleep Stage Classification
Phan, H., Andreotti, F., Cooray, N., Chen, O. Y., & De Vos, M. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2872652 · Cited by 464 · cited 4×
“amount of wake either by using only 30 minutes of wake before and after sleep [11], [18] or by only using the sleep [19], [20], [21].”
BackgroundMethodInfluentialDANKER‐HOPFE, H., ANDERER, P., ZEITLHOFER, J., BOECK, M., DORN, H., GRUBER, G., HELLER, E., LORETZ, E., MOSER, D., PARAPATICS, S., et al. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2008.00700.x · Cited by 417 · cited 6×
“Currently, the manual sleep staging lacks sufficient inter-rater reliability, as perceived from numerous studies [4]– [9].”
BackgroundMethodInfluentialMichielli, N., Acharya, U. R., & Molinari, F. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.01.013 · Cited by 383 · cited 5×
“While some of these have utilized deep learning [10], [11], [14], [16], [18], [19], [21], they have mostly relied on publicly available research datasets with a limited number of healthy individuals.”
BackgroundMethodInfluentialAutomatic Sleep Stage Scoring Using Time-Frequency Analysis and Stacked Sparse Autoencoders
Tsinalis, O., Matthews, P. M., & Guo, Y. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1444-y · Cited by 322 · cited 1×
“amount of wake either by using only 30 minutes of wake before and after sleep [11], [18] or by only using the sleep [19], [20], [21].”
MethodLiang, S.-F., Kuo, C.-E., Hu, Y.-H., Pan, Y.-H., & Wang, Y.-H. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2187242 · Cited by 303
An ensemble system for automatic sleep stage classification using single channel EEG signal
Koley, B., & Dey, D. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.09.012 · Cited by 291 · cited 1×
“Traditionally, automated methods have relied on pre-defined rules, carefully selected features extracted from the signals, and classification algorithms [22]– [26].”
MethodExpert-level sleep scoring with deep neural networks
Biswal, S., Sun, H., Goparaju, B., Westover, M. B., Sun, J., & Bianchi, M. T. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy131 · Cited by 290 · cited 2×
“However, previous studies have generally relied on heavy preprocessing by either transforming the signals into 2D images representing the spectral information [19], [27]–[30] or by reducing the signals into a limited number of predefined features [10], [30], [31].”
BackgroundMethodAnderer, P., Gruber, G., Parapatics, S., Woertz, M., Miazhynskaia, T., Klösch, G., Saletu, B., Zeitlhofer, J., Barbanoj, M. J., Danker-Hopfe, H., et al. (2005) · Neuropsychobiology · doi:10.1159/000085205 · Cited by 284
Automatic Sleep Stage Scoring with Single-Channel EEG Using Convolutional Neural Networks
Tsinalis, O., Matthews, P. M., Guo, Y., & Zafeiriou, S. P. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1610.01683 · Cited by 249 · cited 6×
“amount of wake either by using only 30 minutes of wake before and after sleep [11], [18] or by only using the sleep [19], [20], [21].”
BackgroundMethodResultInfluentialInterobserver Agreement Among Sleep Scorers From Different Centers in a Large Dataset
Norman, R. G., Pal, I., Stewart, C., Walsleben, J. A., & Rapoport, D. M. (2000) · Sleep · doi:10.1093/sleep/23.7.1e · Cited by 246 · cited 6×
“Currently, the manual sleep staging lacks sufficient inter-rater reliability, as perceived from numerous studies [4]– [9].”
BackgroundMethodInfluentialHassan, A. R., & Bhuiyan, M. I. H. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.12.015 · Cited by 239 · cited 1×
“In addition, a few machine learning-based automation attempts have demonstrated promising outcomes on sleep staging with a single EEG channel [10], [11], [13]–[16], [18]–[21].”
BackgroundAgreement in the Scoring of Respiratory Events and Sleep Among International Sleep Centers
Magalang, U. J., Chen, N.-H., Cistulli, P. A., Fedson, A. C., Gíslason, T., Hillman, D., Penzel, T., Tamisier, R., Tufik, S., Phillips, G., et al. (2013) · Sleep · doi:10.5665/sleep.2552 · Cited by 166 · cited 2×
“63 [5], [6], particularly due to poor scoring of N1 sleep [7], [8].”
BackgroundAn end-to-end framework for real-time automatic sleep stage classification
Patanaik, A., Ong, J. L., Gooley, J. J., Ancoli-Israel, S., & Chee, M. W. L. (2018) · Sleep · doi:10.1093/sleep/zsy041 · Cited by 162 · cited 2×
“Furthermore, deep learning models developed on research datasets of healthy individuals have generally suffered from a loss of accuracy when generalizing into populations with sleep disorders such as OSA [28].”
BackgroundThe American Academy of Sleep Medicine Inter-scorer Reliability Program: Respiratory Events
Rosenberg, R. S., & Hout, S. V. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3630 · Cited by 158 · cited 2×
“However, N1 is the most difficult sleep stage to identify even for experienced manual scorers [7], [8].”
BackgroundANALYSIS AND AUTOMATIC IDENTIFICATION OF SLEEP STAGES USING HIGHER ORDER SPECTRA
ACHARYA, U. R., CHUA, E. C.-P., CHUA, K. C., MIN, L. C., & TAMURA, T. (2010) · International Journal of Neural Systems · doi:10.1142/s0129065710002589 · Cited by 153
Automatic Human Sleep Stage Scoring Using Deep Neural Networks
Malafeev, A., Laptev, D., Bauer, S., Omlin, X., Wierzbicka, A., Wichniak, A., Jernajczyk, W., Riener, R., Buhmann, J., & Achermann, P. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00781 · Cited by 151 · cited 1×
“However, previous studies have generally relied on heavy preprocessing by either transforming the signals into 2D images representing the spectral information [19], [27]–[30] or by reducing the signals into a limited number of predefined features [10], [30], [31].”
MethodHassan, A. R., & Bhuiyan, M. I. H. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.09.011 · Cited by 147
Recurrent Deep Neural Networks for Real-Time Sleep Stage Classification From Single Channel EEG
Bresch, E., Großekathöfer, U., & Garcia‐Molina, G. (2018) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2018.00085 · Cited by 116 · cited 2×
“While some of these have utilized deep learning [10], [11], [14], [16], [18], [19], [21], they have mostly relied on publicly available research datasets with a limited number of healthy individuals.”
BackgroundStepnowsky, C., Levendowski, D., Popovic, D., Ayappa, I., & Rapoport, D. M. (2013) · Sleep Medicine · doi:10.1016/j.sleep.2013.04.022 · Cited by 115 · cited 1×
“Traditionally, automated methods have relied on pre-defined rules, carefully selected features extracted from the signals, and classification algorithms [22]– [26].”
MethodMultichannel Sleep Stage Classification and Transfer Learning using Convolutional Neural Networks
Andreotti, F., Phan, H., Cooray, N., Lo, C., Hu, M. T. M., & Vos, M. D. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512214 · Cited by 109 · cited 2×
“smaller Sleep-EDF dataset with only 39 recordings [11], [17], [19]–[21] and thus direct comparison is difficult.”
BackgroundResultLarge-Scale Automated Sleep Staging
Sun, H., Jia, J., Goparaju, B., Huang, G.-B., Sourina, O., Bianchi, M. T., & Westover, M. B. (2017) · Sleep · doi:10.1093/sleep/zsx139 · Cited by 107 · cited 3×
“However, previous studies have generally relied on heavy preprocessing by either transforming the signals into 2D images representing the spectral information [19], [27]–[30] or by reducing the signals into a limited number of predefined features [10], [30], [31].”
BackgroundMethodPortable monitoring for the diagnosis of obstructive sleep apnea
Collop, N. A. (2008) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e328312ed4a · Cited by 97 · cited 2×
“developed and shown to be accurate for the diagnosis of OSA [3].”
BackgroundInter-scorer Reliability between Sleep Centers Can Teach Us What to Improve in the Scoring Rules
Penzel, T., Zhang, X., & Fietze, I. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2352 · Cited by 69 · cited 4×
“problematic for previous automatic sleep staging approaches and even the reliability of manual scoring is known to be lower than with healthy individuals [8], [9], [28].”
BackgroundInfluentialProcess and outcome for international reliability in sleep scoring
Zhang, X., Dong, X., Kantelhardt, J. W., Li, J., Zhao, L., García, C., Glos, M., Penzel, T., & Han, F. (2014) · Sleep And Breathing · doi:10.1007/s11325-014-0990-0 · Cited by 68 · cited 2×
“63 [5], [6], particularly due to poor scoring of N1 sleep [7], [8].”
BackgroundMyllymaa, S., Muraja‐Murro, A., Westeren‐Punnonen, S., Hukkanen, T., Lappalainen, R., Mervaala, E., Töyräs, J., Sipilä, K., & Myllymaa, K. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12425 · Cited by 66 · cited 1×
“ous ambulatory EEG and PSG acquisition systems [40], [41].”
BackgroundSelf-citationArnardóttir, E. S., Verbraecken, J. A., Gonçalves, M., Gjerstad, M. D., Grote, L., Puertas, F. J., Mihaicuta, S. D., McNicholas, W. T., Parrino, L., & Collaborators, T. N. R. A. S. (2015) · Journal of Sleep Research · doi:10.1111/jsr.12353 · Cited by 43 · cited 1×
“Ambulatory recordings are even the preferred diagnostic method in some healthcare systems [42], [43].”
MethodMiettinen, T., Myllymaa, K., Westerén-Punnonen, S., Ahlberg, J., Hukkanen, T., Töyräs, J., Lappalainen, R., Mervaala, E., Sipilä, K., & Myllymaa, S. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2741522 · Cited by 43 · cited 1×
“ous ambulatory EEG and PSG acquisition systems [40], [41].”
BackgroundSelf-citationEnd-to-end Sleep Staging with Raw Single Channel EEG using Deep Residual ConvNets
Humayun, A. I., Sushmit, A. S., Hasan, T., & Bhuiyan, M. I. H. (2019) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2019.8834483 · Cited by 43 · cited 3×
“While some of these have utilized deep learning [10], [11], [14], [16], [18], [19], [21], they have mostly relied on publicly available research datasets with a limited number of healthy individuals.”
Background
Metadata
- Authors
- Korkalainen, H., Leppanen, T., Aakko, J., Nikkonen, S., Kainulainen, S., Leino, A., Duce, B., Afara, I. O., Myllymaa, S., & Toyras, J.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019
- Volume
- 24
- Issue
- 7
- Pages
- 1-1
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2995516697
- Cited by
- 160
- References
- 44
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.