Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part, then their destabilization is generally prevented. This paper presents an overview of passivity-based stability assessment, including techniques for space-vector modeling of VSCs whereby expressions for the input admittance can be derived. Design recommendations for minimizing the negative-real-part region are given as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Instantaneous Power Theory and Applications to Power Conditioning
Akagi, H., Watanabe, E. H., & Aredes, M. (2007) · Wiley eBooks · doi:10.1002/0470118938 · Cited by 2,234
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Self-citationModeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785
Self-citationVirtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Self-citationDigital Control in Power Electronics
Buso, S., & Mattavelli, P. (2006) · Synthesis lectures on power electronics · doi:10.2200/s00047ed1v01y200609pel002 · Cited by 535
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Global Energy Scenario and Impact of Power Electronics in 21st Century
Bose, B. K. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2203771 · Cited by 476 · cited 1×
“THE PENETRATION of grid-connected converters, particularly voltage-source converters (VSCs), is currently rising rapidly [1].”
Background
Cited by
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Self-citationGrid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationDesign-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Self-citationWang, L., Qin, Z., Slangen, T., Bauer, P., & van Wijk, T. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3054601 · Cited by 417
Xie, X., Zhang, X., Liu, H., Liu, H., Li, Y., & Zhang, C. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2676024 · Cited by 381
Wu, H., & Wang, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2976791 · Cited by 227
“Yet, the total delay time is usually around hundreds of microseconds [2], which is much less than the response time of power loops (usually longer than 100 ms [28]) that determine the transient stability of the VSG.”
BackgroundSelf-citationImpedance Circuit Model of Grid-Forming Inverter: Visualizing Control Algorithms as Circuit Elements
Li, Y., Gu, Y., Zhu, Y., Junyent-Ferre, A., Xiang, X., & Green, T. C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3015158 · Cited by 207
“, passivity [44]) of each controller parameters can also be evaluated directly from the corresponding virtual impedance, which can straightforwardly guide the controller design and parameter tuning in practice.”
BackgroundXiong, X., Wu, C., Hu, B., Pan, D., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3046462 · Cited by 202
“Usually, the inner loop's bandwidth is much higher than that of the outer power control loop [22], [23].”
BackgroundSelf-citationCatalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
“Impedance-based stability analysis methods [157], [158],”
Cyber Security in Control of Grid-Tied Power Electronic Converters—Challenges and Vulnerabilities
Sahoo, S., Dragičević, T., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2953480 · Cited by 194
Self-citationXiong, X., Wu, C., & Blaabjerg, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3052350 · Cited by 181
Self-citation
Metadata
- Authors
- Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2016-03
- Volume
- 4
- Issue
- 1
- Pages
- 116-125
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2280707463
- Cited by
- 674
- References
- 21
- FWCI
- 39.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.