Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transient Damping Method for Improving the Synchronization Stability of Virtual Synchronous Generators

Open access
Xiong, Xiaoling, Wu, Chao, Hu, Bin, Pan, Donghua, Blaabjerg, Frede · 2021 · IEEE Transactions on Power Electronics

Abstract

The virtual synchronous generator (VSG) was proposed to emulate a synchronous machine's dynamics when integrating power electronic converter-based distributed energy resources to the power grid. However, the VSG's synchronization stability during grid faults is not fully explored. The underlying mechanism of loss of synchronization still needs to be further revealed due to VSG's nonlinear characteristics. In this article, a step-by-step analytical method based on combining the linear and nonlinear models is proposed to analyze VSG's dynamic behaviors during a large disturbance. The relationship between the linear and nonlinear models is first brought to light, showing that the linear model is suitable for qualitative analysis to give an intuitive physical insight. Simultaneously, the latter is adopted for quantitative analysis to assess stability after a grid fault. Moreover, to avoid the conflict of the synchronization stability and the inertia response, a transient damping method is added in the active power control loop, which can simultaneously improve the synchronization stability and frequency stability. Design guidelines are also proposed to identify the parameter of the transient damping with different inertia requirements. Finally, the experimental results verify the analytical method and the theoretical analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpel.2020.3046462

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Xiong, X., Wu, C., Hu, B., Pan, D., & Blaabjerg, F.
Venue
IEEE Transactions on Power Electronics
Published
2021-07
Volume
36
Issue
7
Pages
7820-7831
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W3115441025
Cited by
202
References
1
FWCI
9.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transient Damping Method for Improving the Synchronization Stability of Virtual Synchronous Generators. https://app.cochat.ai/papers/10.1109/tpel.2020.3046462
The paper
Xiong, X., Wu, C., Hu, B., Pan, D., & Blaabjerg, F. (2021). Transient Damping Method for Improving the Synchronization Stability of Virtual Synchronous Generators. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2020.3046462

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.