A Virtual Synchronous Control for Voltage-Source Converters Utilizing Dynamics of DC-Link Capacitor to Realize Self-Synchronization
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Voltage-source converters (VSCs) are widely used in renewable energy sources as the grid interface, e.g., wind turbine generators and photovoltaics. These VSCs control the dc-link capacitor voltage and the reactive power output to track the reference values, which generally apply phase-locked loop (PLL) for grid synchronization. However, the dynamic performance of the conventional PLL can be deteriorated when the VSC is integrated into weak grids, which may even cause instability of the VSC. In this paper, a virtual synchronous control (ViSynC) is proposed for VSCs, which utilizes the dynamics of the dc-link capacitor to realize self-synchronization. Grid synchronization mechanism of the ViSynC-based VSC is particularly analyzed in this paper. The ViSynC-based VSC can provide inertial responses to the grid, and has the advantage that it can operate normally under weak grid conditions without any modification of the grid synchronization unit. Furthermore, virtual impedance and Q-V droop control can be easily implemented in the control structure of the ViSynC. Simulations based on MATLAB/ Simulink and hardware-in-the-loop real-time simulations based on RT-LAB verify the effectiveness of the proposed ViSynC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
A Comparative Study on Maximum Power Point Tracking Techniques for Photovoltaic Power Systems
Subudhi, B., & Pradhan, R. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2202294 · Cited by 1,867
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Multivariable Feedback Control
(2005) · Advances in Industrial Control · doi:10.1007/1-84628-092-3_5 · Cited by 1,288
Cited by
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Tayyebi, A., Gross, D., Anta, A., Kupzog, F., & Dorfler, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2966524 · Cited by 442
“Matching control is a grid-forming control strategy that exploits structural similarities between power converters and SMs [10]–[13], [40] and is based on the observation that the dc-link voltage - similar to the synchronous machine frequency - indicates power imbalances.”
BackgroundA Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“The priority-based limiter implemented in the dq-frame is represented as [15], [29], [41], [42]”
MethodPlacing Grid-Forming Converters to Enhance Small Signal Stability of PLL-Integrated Power Systems
Yang, C., Huang, L., Xin, H., & Ju, P. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3042741 · Cited by 279
Self-citationOvercurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430316 · Cited by 271
Mohammed, N., Udawatte, H., Zhou, W., Hill, D. J., & Bahrani, B. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3371985 · Cited by 183
Fang, J., Zhang, R., Li, H., & Tang, Y. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2871085 · Cited by 170
Ravanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2017-12
- Volume
- 5
- Issue
- 4
- Pages
- 1565-1577
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2747381363
- Cited by
- 342
- References
- 40
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.